2 resultados para droop gain settings
Resumo:
The aim of this research study has been to design a gain scheduling (GS) digital controller in order to control the voltage of an islanded microgrid in the presence of fast varying loads (FVLs), and to compare it to a robust controller. The inverter which feeds the microgrid is connected to it through an inductance-capacitor-inductance (LCL) filter. The oscillatory and nonlinear behaviour of the plant is analyzed in the whole operating zone. Afterwards, the design of the controllers which contain two loops in cascade are described. The first loop concerns the current control, while the second is linked to the voltage regulation. Two controllers, one defined as Robust and another one as GS controller, are designed for the two loops, emphasizing in their robustness and their ability to damp the oscillatory plant behaviour. To finish, some simulations are carried out to study and compare the two kinds of controllers in different operating points. The results show that both controllers damp the oscillatory behaviour of the plant in closed loop (CL), and that the GS controller ensures a better rejection of current disturbances from FVLs.
Resumo:
[EN]This paper presents a project within that research field. The project consists on the development of an experimental environment comprised by a sensorized practice manikin and a management software system. Manikin model allows the simulation of cardiac arrest episodes on laboratory settings. The management software system adds the capacity to compute and analyze the characteristics of the artifact induced on the electrocardiogram and the thoracic impedance signals by chest compressions during cardiopulmonary resuscitation due to variations of the electrode-skin interface. The main reason for choosing this kind of model is the impossibility to use real people because of the risk of thoracic injuries during chest compression. Moreover, this platform could be used for training in reanimation techniques for real situations. Even laypeople with minimal training can perform cardiopulmonary resuscitation. This can reduce the response time to an emergency while the healthcare personnel arrives, which is key to improve outcomes, since with every minute the chances of survival decrease approximately 10%. It is not necessary to have medical knowledge to perform cardiopulmonary resuscitation, which could increase chances of survival for a patient with an early reanimation since In this context, this paper details the technique solution for the manikin sensorisation to acquire the electrocardiogram, the impedance signal measured between the defibrillation pads placed on the patient’s chest, the compression depth, the compression force and the acceleration experienced by the chest in the three orthogonal axes. Moreover, it is possible to inject a previously recorded electrocardiogram signal.