4 resultados para Tatian, ca. 120-173.


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La tesis se ha centrado en la síntesis y caracterización estructural de materiales tipo perovskita: SrLnMRuO6 (Ln=La,Pr,Nd; M=Zn,Co,Mg,Ni,Fe) y ALn2CuTi2O9 (A=Ca,Ba; Ln=La,Pr,Nd,Sm). El estudio de las estructuras de los materiales se ha realizado mediante el análisis de los patrones de difracción en polvo de rayos-X, sincrotrón y/o neutrones. En el refinamiento por el método de Rietveld de las estructuras se han sustituido las coordenadas atómicas (el método más común), por coordenadas colectivas: las amplitudes de los modos que describen la distorsión de la fase prototipo. Los resultados generales para la serie SrLnMRuO6 (Ln=La,Pr,Nd; M=Zn,Co,Mg,Ni) a temperatura ambiente se ha recogido en un diagrama en el que se han indicado las amplitudes de los modos que transforman de acuerdo a las irreps en función del factor de tolerancia, ya que todos ellos cristalizan en la misma fase monoclínica (P21/n); y a temperaturas altas se ha construido un diagrama de fase. Los materiales SrLnFeRuO6 ( Ln=La,Pr,Nd) y CaLn2CuTi2O9 cristalizan en la fase ortorrómbica Pbnm a temperatura ambiente; mientras que BaLn2CuTi2O9 tienen una estructura más simétrica, I4/mcm. A altas temperaturas se han identificado las transiciones de fase inducidas por el cambio de temperatura.A temperaturas bajas se han analizado las estructuras magnéticas de algunos de los compuestos mediante difracción de neutrones.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lan honen helburua La1-x Cax MnO3 [x ~ 0.2] (perovskiten familiakoa) laginaren azterketan oinarritzen da. "High resolution dielectric analyzer" tresnari esker permitibitate dielektrikoa neurtuko da eta honen bitartez erresistentzia eta eroankortasun elektrikoa. Azterketa hau [10-2, 107] Hz maiztasun-tarte batean eta tenperatura desberdinetan (150K, 170K, 190K, 210K, 230K, 300K) burutuko da, ondoren materialak magnitude hauen bariazioekiko duen erantzuna aztertuz.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Resumen Background: Nitric oxide can be measured at multiple flow rates to determine proximal (maximum airway nitric oxide flux; Jaw(NO)) and distal inflammation (alveolar nitric oxide concentration; CA(NO)). The main aim was to study the association among symptoms, lung function, proximal (maximum airway nitric oxide flux) and distal (alveolar nitric oxide concentration) airway inflammation in asthmatic children treated and not treated with inhaled glucocorticoids. Methods: A cross-sectional study with prospective data collection was carried out in a consecutive sample of girls and boys aged between 6 and 16 years with a medical diagnosis of asthma. Maximum airway nitric oxide flux and alveolar nitric oxide concentration were calculated according to the two-compartment model. In asthmatic patients, the asthma control questionnaire (CAN) was completed and forced spirometry was performed. In controls, differences between the sexes in alveolar nitric oxide concentration and maximum airway nitric oxide flux and their correlation with height were studied. The correlation among the fraction of exhaled NO at 50 ml/s (FENO50), CA(NO), Jaw(NO), forced expiratory volume in 1 second (FEV1) and the CAN questionnaire was measured and the degree of agreement regarding asthma control assessment was studied using Cohen's kappa. Results: We studied 162 children; 49 healthy (group 1), 23 asthmatic participants without treatment (group 2) and 80 asthmatic patients treated with inhaled corticosteroids (group 3). CA(NO) (ppb) was 2.2 (0.1-4.5), 3 (0.2-9.2) and 2.45 (0.1-24), respectively. Jaw(NO) (pl/s) was 516 (98.3-1470), 2356.67 (120-6110) and 1426 (156-11805), respectively. There was a strong association (r = 0.97) between FENO50 and Jaw(NO) and the degree of agreement was very good in group 2 and was good in group 3. There was no agreement or only slight agreement between the measures used to monitor asthma control (FEV1, CAN questionnaire, CA(NO) and Jaw(NO)). Conclusions: The results for CA(NO) and Jaw(NO) in controls were similar to those found in other reports. There was no agreement or only slight agreement among the three measure instruments analyzed to assess asthma control. In our sample, no additional information was provided by CA(NO) and Jaw(NO).