2 resultados para upper miocene

em Archivo Digital para la Docencia y la Investigación - Repositorio Institucional de la Universidad del País Vasco


Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work we perform for the first time a palaeoenvironmental and biostratigraphic analysis of the lower Miocene alluvial deposits of the Cenicero section (NW sector of the Ebro Basin; N Iberian Peninsula), based on the ostracod and micromammal assemblages. One of the main characteristics of this section is the unusual abundance on non-reworked ostracods present in the studied samples compared to other European sequences of similar age and sedimentary environment. This fact has allowed us to develop precise palaeoenvironmental reconstructions. The variations of the identified ostracod assemblages, defined by species such as Cyclocypris laevis, Ilyocypris bradyi, Ilyocypris gibba, Limnocythere sp. or Pseudocandona parallela, record the development of small, ephemeral and shallow ponds in a distal alluvial and/or floodplain environment. Towards the upper part of the section the ponds appear to be less ephemeral, being the aquatic systems more stable for ostracods development. Variations in the water temperature and salinity have been observed along the section, which are related to changes in the local pluviometric regime. On the other hand, the presence of micromammals in one of the studied samples has allowed the precise dating of this section. Thus, the presence of Armantomys daamsi dates the Cenicero section as Agenian (lower Miocene), local zone Y2 (MN2).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Aerosol delivery holds potential to release surfactant or perfluorocarbon (PFC) to the lungs of neonates with respiratory distress syndrome with minimal airway manipulation. Nevertheless, lung deposition in neonates tends to be very low due to extremely low lung volumes, narrow airways and high respiratory rates. In the present study, the feasibility of enhancing lung deposition by intracorporeal delivery of aerosols was investigated using a physical model of neonatal conducting airways. Methods: The main characteristics of the surfactant and PFC aerosols produced by a nebulization system, including the distal air pressure and air flow rate, liquid flow rate and mass median aerodynamic diameter (MMAD), were measured at different driving pressures (4-7 bar). Then, a three-dimensional model of the upper conducting airways of a neonate was manufactured by rapid prototyping and a deposition study was conducted. Results: The nebulization system produced relatively large amounts of aerosol ranging between 0.3 +/- 0.0 ml/min for surfactant at a driving pressure of 4 bar, and 2.0 +/- 0.1 ml/min for distilled water (H(2)Od) at 6 bar, with MMADs between 2.61 +/- 0.1 mu m for PFD at 7 bar and 10.18 +/- 0.4 mu m for FC-75 at 6 bar. The deposition study showed that for surfactant and H(2)Od aerosols, the highest percentage of the aerosolized mass (similar to 65%) was collected beyond the third generation of branching in the airway model. The use of this delivery system in combination with continuous positive airway pressure set at 5 cmH(2)O only increased total airway pressure by 1.59 cmH(2)O at the highest driving pressure (7 bar). Conclusion: This aerosol generating system has the potential to deliver relatively large amounts of surfactant and PFC beyond the third generation of branching in a neonatal airway model with minimal alteration of pre-set respiratory support.