19 resultados para Visual feedback

em Archivo Digital para la Docencia y la Investigación - Repositorio Institucional de la Universidad del País Vasco


Relevância:

20.00% 20.00%

Publicador:

Resumo:

903 páginas, bibliografía en páginas 854-895, glosario en páginas 896-903

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ponencia leída en el Foro de Comunicaciones IkasArt II (BEC Barakaldo, 2010.06.18)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ponencia leída en el Foro de Comunicaciones IkasArt II (BEC Barakaldo, 2010.06.18)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The stabilization of dynamic switched control systems is focused on and based on an operator-based formulation. It is assumed that the controlled object and the controller are described by sequences of closed operator pairs (L, C) on a Hilbert space H of the input and output spaces and it is related to the existence of the inverse of the resulting input-output operator being admissible and bounded. The technical mechanism addressed to get the results is the appropriate use of the fact that closed operators being sufficiently close to bounded operators, in terms of the gap metric, are also bounded. That philosophy is followed for the operators describing the input-output relations in switched feedback control systems so as to guarantee the closed-loop stabilization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present thesis is focuses on the problem of Simultaneous Localisation and Mapping (SLAM) using only visual data (VSLAM). This means to concurrently estimate the position of a moving camera and to create a consistent map of the environment. Since implementing a whole VSLAM system is out of the scope of a degree thesis, the main aim is to improve an existing visual SLAM system by complementing the commonly used point features with straight line primitives. This enables more accurate localization in environments with few feature points, like corridors. As a foundation for the project, ScaViSLAM by Strasdat et al. is used, which is a state-of-the-art real-time visual SLAM framework. Since it currently only supports Stereo and RGB-D systems, implementing a Monocular approach will be researched as well as an integration of it as a ROS package in order to deploy it on a mobile robot. For the experimental results, the Care-O-bot service robot developed by Fraunhofer IPA will be used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a vaccination strategy for fighting against the propagation of epidemic diseases. The disease propagation is described by an SEIR (susceptible plus infected plus infectious plus removed populations) epidemic model. The model takes into account the total population amounts as a refrain for the illness transmission since its increase makes the contacts among susceptible and infected more difficult. The vaccination strategy is based on a continuous-time nonlinear control law synthesised via an exact feedback input-output linearization approach. An observer is incorporated into the control scheme to provide online estimates for the susceptible and infected populations in the case when their values are not available from online measurement but they are necessary to implement the control law. The vaccination control is generated based on the information provided by the observer. The control objective is to asymptotically eradicate the infection from the population so that the removed-by-immunity population asymptotically tracks the whole one without precise knowledge of the partial populations. The model positivity, the eradication of the infection under feedback vaccination laws and the stability properties as well as the asymptotic convergence of the estimation errors to zero as time tends to infinity are investigated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La aplicaci�n de campos geomagn�ticos con la polaridad cambiante promueve la plasticidad de la corteza visual de animales privados visualmente mediante la cr�a en oscuridad, o bien a trav�s de la sutura palpebral de un ojo.Esto es debido a que la estimulaci�n magn�tica produce la down-regulaci�n de la expresi�n de los microRNAs let-7b*, miR-330, miR-338* y miR-376c en la corteza visual de animales sometidos a la cr�a en oscuridad, as� como de animales sujetos a sutura palpebral de un ojo. Como consecuencia de la down-regulaci�n de la expresi�n de los microRNAs citados anteriormente, se ven incrementados los niveles de expresi�n de sus correspondientes mol�culas diana, Conexina 26 para el caso de let-7b*, Tenascina R en el caso de miR-330, Contactina 4 para el caso de miR-338* y Matriz metalopeptidasa 9 y �-sinucle�na, ambas mol�culas diana de miR-376c. El aumento de expresi�n de estas mol�culas diana a nivel de RNA mensajero, as� como a nivel de prote�na en la corteza visual promueve la capacidad pl�stica de la corteza visual, ya que estas mol�culas diana se encuentran implicadas en procesos de crecimiento/elongaci�n de las neuritas y en la regulaci�n de la morfolog�a de las espinas dendr�ticas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Little is known about the types of 'sit less, move more' strategies that appeal to office employees, or what factors influence their use. This study assessed the uptake of strategies in Spanish university office employees engaged in an intervention, and those factors that enabled or limited strategy uptake. Methods: The study used a mixed method design. Semi-structured interviews were conducted with academics and administrators (n = 12; 44 +/- 12 mean SD age; 6 women) at three points across the five-month intervention, and data used to identify factors that influenced the uptake of strategies. Employees who finished the intervention then completed a survey rating (n = 88; 42 +/- 8 mean SD age; 51 women) the extent to which strategies were used [never (1) to usually (4)]; additional survey items (generated from interviewee data) rated the impact of factors that enabled or limited strategy uptake [no influence (1) to very strong influence (4)]. Survey score distributions and averages were calculated and findings triangulated with interview data. Results: Relative to baseline, 67% of the sample increased step counts post intervention (n = 59); 60% decreased occupational sitting (n = 53). 'Active work tasks' and 'increases in walking intensity' were the strategies most frequently used by employees (89% and 94% sometimes or usually utilised these strategies); 'walk-talk meetings' and ` lunchtime walking groups' were the least used (80% and 96% hardly ever or never utilised these strategies). 'Sitting time and step count logging' was the most important enabler of behaviour change (mean survey score of 3.1 +/- 0.8); interviewees highlighted the motivational value of being able to view logged data through visual graphics in a dedicated website, and gain feedback on progress against set goals. 'Screen based work' (mean survey score of 3.2 +/- 0.8) was the most significant barrier limiting the uptake of strategies. Inherent time pressures and cultural norms that dictated sedentary work practices limited the adoption of 'walk-talk meetings' and ` lunch time walking groups'. Conclusions: The findings provide practical insights into which strategies and influences practitioners need to target to maximise the impact of 'sit less, move more' occupational intervention strategies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[Es]En este trabajo se analiza la posibilidad de utilizar los sistemas de feedback comerciales más conocidos (TrueCPR de la empresa Physio-Control y CPRmeter de Laerdal) en un tren de larga distancia. Se trata de estudiar su habilidad y precisión tanto en profundidad de compresión como en frecuencia. Para nes comparativos, también ha sido necesario analizar la precisión de ambos equipos en condiciones de laboratorio.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[EN]Hyperventilation, which is common both in-hospital and out-of-hospital cardiac arrest, decreases coronary and cerebral perfusion contributing to poorer survival rates in both animals and humans. Current resucitation guidelines recommend continuous monitoring of exhaled carbon dioxide (CO2) during cardiopulmonary resucitation (CPR) and emphasize good quality of CPR, including ventilations at 8-10 min1. Most of commercial monitors/de- brilators incorporate methods to compute the respiratory rate based on capnography since it shows uctuations caused by ventilations. Chest compressions may induce artifacts in this signal making the calculation of the respiratory rate di cult. Nevertheless, the accuracy of these methods during CPR has not been documented yet. The aim of this project is to analyze whether the capnogram is reliable to compute ventilation rate during CPR. A total of 91 episodes, 63 out-of-hospital cardiac arrest episodes ( rst database) and 28 in-hospital cardiac arrest episodes (second database) were used to develop an algorithm to detect ventilations in the capnogram, and the nal aim is to provide an accurate ventilation rate for feedback purposes during CPR. Two graphic user interfaces were developed to make the analysis easier and another two were adapted to carry out this project. The use of this interfaces facilitates the managment of the databases and the calculation of the algorithm accuracy. In the rst database, as gold standard every ventilation was marked by visual inspection of both the impedance, which shows uctuations with every ventilation, and the capnography signal. In the second database, volume of the respiratory ow signal was used as gold standard to mark ventilation instants since it is not a ected by chest compressions. The capnogram was preprocessed to remove high frequency noise, and the rst di erence was computed to de ne the onset of inspiration and expiration. Then, morphological features were extracted and a decission algorithm built based on the extracted features to detect ventilation instants. Finally, ventilation rate was calculated using the detected instants of ventilation. According to the results obtained in this project, the capnogram can be reliably used to give feedback ventilation rate, and therefore, on hyperventilation in a resucitation scenario.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El presente trabajo constó de una revisión bibliográfica sobre el esquí alpino adaptado para personas con discapacidad física, sensorial visual e intelectual. En él se describieron las diferentes discapacidades nombradas anteriormente y se recogió la historia del deporte adaptado en general y del esquí alpino adaptado en particular, así como los beneficios psicológicos y psicomotores que aporta en cada una de las tres discapacidades. También se describieron los tipos de material adaptado necesario para su práctica según las discapacidades del deportista; la metodología de enseñanza-aprendizaje y la técnica, desde su evolución hasta las nuevas tendencias metodológicas; el reglamento especial y los factores de riesgo que existen en la competición y las lesiones más frecuentes, analizando los tipos, causas, mecanismo y prevención.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quality of cardiopulmonary resuscitation (CPR) improves through the use of CPR feedback devices. Most feedback devices integrate the acceleration twice to estimate compression depth. However, they use additional sensors or processing techniques to compensate for large displacement drifts caused by integration. This study introduces an accelerometer-based method that avoids integration by using spectral techniques on short duration acceleration intervals. We used a manikin placed on a hard surface, a sternal triaxial accelerometer, and a photoelectric distance sensor (gold standard). Twenty volunteers provided 60 s of continuous compressions to test various rates (80-140 min(-1)), depths (3-5 cm), and accelerometer misalignment conditions. A total of 320 records with 35312 compressions were analysed. The global root-mean-square errors in rate and depth were below 1.5 min(-1) and 2 mm for analysis intervals between 2 and 5 s. For 3 s analysis intervals the 95% levels of agreement between the method and the gold standard were within -1.64-1.67 min(-1) and -1.69-1.72 mm, respectively. Accurate feedback on chest compression rate and depth is feasible applying spectral techniques to the acceleration. The method avoids additional techniques to compensate for the integration displacement drift, improving accuracy, and simplifying current accelerometer-based devices.