6 resultados para UV FLUORESCENCE

em Archivo Digital para la Docencia y la Investigación - Repositorio Institucional de la Universidad del País Vasco


Relevância:

20.00% 20.00%

Publicador:

Resumo:

[EN] This paper reports an innovative technique for reagents storage in microfluidic devices by means of a one-step UV-photoprintable ionogel-based microarray on non-modified polymeric substrates. Although the ionogel and the ink-jet printing technology are well published, this is the first study where both are used for long-term reagent storage in lab-on-a-chip devices. This technology for reagent storage is perfectly compatible with mass production fabrication processes since pre-treatment of the device substrate is not necessary and inkjet printing allows for an efficient reagent deposition process. The functionality of this microarray is demonstrated by testing the release of biotin-647 after being stored for 1 month at room temperature. Analysis of the fluorescence of the ionogel-based microarray that contains biotin-647 demonstrated that 90% of the biotin-647 present was released from the ionogel-based microarray after pumping PBS 0.1% Tween at 37 °C. Moreover, the activity of biotin-647 after being released from the ionogel-based microarray was investigated trough the binding capability of this biotin to a microcontact printed chip surface with avidin. These findings pave the way for a novel, one-step, cheap and mass production on-chip reagents storage method applicable to other reagents such as antibodies and proteins and enzymes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Familial hypercholesterolemia (FH) is a common autosomal codominant disease with a frequency of 1:500 individuals in its heterozygous form. The genetic basis of FH is most commonly mutations within the LDLR gene. Assessing the pathogenicity of LDLR variants is particularly important to give a patient a definitive diagnosis of FH. Current studies of LDLR activity ex vivo are based on the analysis of I-125-labeled lipoproteins (reference method) or fluorescent-labelled LDL. The main purpose of this study was to compare the effectiveness of these two methods to assess LDLR functionality in order to validate a functional assay to analyse LDLR mutations. LDLR activity of different variants has been studied by flow cytometry using FITC-labelled LDL and compared with studies performed previously with I-125-labeled lipoproteins. Flow cytometry results are in full agreement with the data obtained by the I-125 methodology. Additionally confocal microscopy allowed the assignment of different class mutation to the variants assayed. Use of fluorescence yielded similar results than I-125-labeled lipoproteins concerning LDLR activity determination, and also allows class mutation classification. The use of FITC-labelled LDL is easier in handling and disposal, cheaper than radioactivity and can be routinely performed by any group doing LDLR functional validations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Empleo de la técnica BiFC para estudiar la interacción entre los canales Kv7.2 y la CaM. Para ello se realizan clonajes, se co-transfectan distintas combinaciones de éstos en células de mamífero y se analiza y cuantifica la intensidad de fluorescencia obtenida mediante microscopía confocal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[EN] In the recent years a series of optical correlation techniques have been developed in order to be able to measure flow velocity with high spatial resolution while being non-invasive in order to be employed in-vivo on biological organisms. The technique employed in my thesis work, scanning laser image correlation (SLIC), is a powerful approach for the detection of flow motions because it overcomes some limitations of the classical spectroscopy techniques. SLIC method consists in repeated laser scans over a linear pattern and on the cross correlation of the signal emitted by the excited fluorophores in different positions along the scan line. Therefore, the resulting measurements for flow velocity are really accurate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

23rd Congress of the International Comission for Optics (ICO 23)