6 resultados para The Studio Model
em Archivo Digital para la Docencia y la Investigación - Repositorio Institucional de la Universidad del País Vasco
Resumo:
[EN]In this paper we deal with probability distributions over permutation spaces. The Probability model in use is the Mallows model. The distance for permutations that the model uses in the Ulam distance.
Resumo:
31 p.
Resumo:
24 p.
Resumo:
Feature-based vocoders, e.g., STRAIGHT, offer a way to manipulate the perceived characteristics of the speech signal in speech transformation and synthesis. For the harmonic model, which provide excellent perceived quality, features for the amplitude parameters already exist (e.g., Line Spectral Frequencies (LSF), Mel-Frequency Cepstral Coefficients (MFCC)). However, because of the wrapping of the phase parameters, phase features are more difficult to design. To randomize the phase of the harmonic model during synthesis, a voicing feature is commonly used, which distinguishes voiced and unvoiced segments. However, voice production allows smooth transitions between voiced/unvoiced states which makes voicing segmentation sometimes tricky to estimate. In this article, two-phase features are suggested to represent the phase of the harmonic model in a uniform way, without voicing decision. The synthesis quality of the resulting vocoder has been evaluated, using subjective listening tests, in the context of resynthesis, pitch scaling, and Hidden Markov Model (HMM)-based synthesis. The experiments show that the suggested signal model is comparable to STRAIGHT or even better in some scenarios. They also reveal some limitations of the harmonic framework itself in the case of high fundamental frequencies.
Resumo:
This paper estimates a standard version of the New Keynesian monetary (NKM) model under alternative specifications of the monetary policy rule using U.S. and Eurozone data. The estimation procedure implemented is a classical method based on the indirect inference principle. An unrestricted VAR is considered as the auxiliary model. On the one hand, the estimation method proposed overcomes some of the shortcomings of using a structural VAR as the auxiliary model in order to identify the impulse response that defines the minimum distance estimator implemented in the literature. On the other hand, by following a classical approach we can further assess the estimation results found in recent papers that follow a maximum-likelihood Bayesian approach. The estimation results show that some structural parameter estimates are quite sensitive to the specification of monetary policy. Moreover, the estimation results in the U.S. show that the fit of the NKM under an optimal monetary plan is much worse than the fit of the NKM model assuming a forward-looking Taylor rule. In contrast to the U.S. case, in the Eurozone the best fit is obtained assuming a backward-looking Taylor rule, but the improvement is rather small with respect to assuming either a forward-looking Taylor rule or an optimal plan.
Resumo:
Objective: Aerosol delivery holds potential to release surfactant or perfluorocarbon (PFC) to the lungs of neonates with respiratory distress syndrome with minimal airway manipulation. Nevertheless, lung deposition in neonates tends to be very low due to extremely low lung volumes, narrow airways and high respiratory rates. In the present study, the feasibility of enhancing lung deposition by intracorporeal delivery of aerosols was investigated using a physical model of neonatal conducting airways. Methods: The main characteristics of the surfactant and PFC aerosols produced by a nebulization system, including the distal air pressure and air flow rate, liquid flow rate and mass median aerodynamic diameter (MMAD), were measured at different driving pressures (4-7 bar). Then, a three-dimensional model of the upper conducting airways of a neonate was manufactured by rapid prototyping and a deposition study was conducted. Results: The nebulization system produced relatively large amounts of aerosol ranging between 0.3 +/- 0.0 ml/min for surfactant at a driving pressure of 4 bar, and 2.0 +/- 0.1 ml/min for distilled water (H(2)Od) at 6 bar, with MMADs between 2.61 +/- 0.1 mu m for PFD at 7 bar and 10.18 +/- 0.4 mu m for FC-75 at 6 bar. The deposition study showed that for surfactant and H(2)Od aerosols, the highest percentage of the aerosolized mass (similar to 65%) was collected beyond the third generation of branching in the airway model. The use of this delivery system in combination with continuous positive airway pressure set at 5 cmH(2)O only increased total airway pressure by 1.59 cmH(2)O at the highest driving pressure (7 bar). Conclusion: This aerosol generating system has the potential to deliver relatively large amounts of surfactant and PFC beyond the third generation of branching in a neonatal airway model with minimal alteration of pre-set respiratory support.