3 resultados para Sediment quality guidelines

em Archivo Digital para la Docencia y la Investigación - Repositorio Institucional de la Universidad del País Vasco


Relevância:

30.00% 30.00%

Publicador:

Resumo:

[EN]The present research work, based on some of the components of the Common Assessment Framework, sets to analyse the influence held by leadership in specific factors that constitute the organisational climate, and also the impact that these factors have on the quality of municipal public services. For the purposes of this study, we propose Likert’s exploitative autocratic and participative leadership styles to explain the genesis, structure and workflow. As far as the organisational climate is concerned, the variables used are motivation, satisfaction, empowerment, conflict and stress. The main conclusions that arose was that a participative leader confers higher relevance to the quality of service, through motivation, satisfaction, empowerment and human resources positive results, than an exploitative autocratic leader. Performed contributions are based on the empiric research hereby presented, and new research guidelines are proposed. The research methodology used was qualitative, based on the case study.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Neonatal trials remain difficult to conduct for several reasons: in particular the need for study sites to have an existing infrastructure in place, with trained investigators and validated quality procedures to ensure good clinical, laboratory practices and a respect for high ethical standards. The objective of this work was to identify the major criteria considered necessary for selecting neonatal intensive care units that are able to perform drug evaluations competently. Methodology and Main Findings: This Delphi process was conducted with an international multidisciplinary panel of 25 experts from 13 countries, selected to be part of two committees (a scientific committee and an expert committee), in order to validate criteria required to perform drug evaluation in neonates. Eighty six items were initially selected and classified under 7 headings: "NICUs description - Level of care'' (21), "Ability to perform drug trials: NICU organization and processes (15), "Research Experience'' (12), "Scientific competencies and area of expertise'' (8), "Quality Management'' (16), "Training and educational capacity'' (8) and "Public involvement'' (6). Sixty-one items were retained and headings were rearranged after the first round, 34 were selected after the second round. A third round was required to validate 13 additional items. The final set includes 47 items divided under 5 headings. Conclusion: A set of 47 relevant criteria will help to NICUs that want to implement, conduct or participate in drug trials within a neonatal network identify important issues to be aware of. Summary Points: 1) Neonatal trials remain difficult to conduct for several reasons: in particular the need for study sites to have an existing infrastructure in place, with trained investigators and validated quality procedures to ensure good clinical, laboratory practices and a respect for high ethical standards. 2) The present Delphi study was conducted with an international multidisciplinary panel of 25 experts from 13 countries and aims to identify the major criteria considered necessary for selecting neonatal intensive care units (NICUs) that are able to perform drug evaluations competently. 3) Of the 86 items initially selected and classified under 7 headings - "NICUs description - Level of care'' (21), "Ability to perform drug trials: NICU organization and processes (15), "Research Experience'' (12), "Scientific competencies and area of expertise'' (8), "Quality Management'' (16), "Training and educational capacity'' (8) and "Public involvement'' (6) - 47 items were selected following a three rounds Delphi process. 4) The present consensus will help NICUs to implement, conduct or participate in drug trials within a neonatal network.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Quality of cardiopulmonary resuscitation (CPR) improves through the use of CPR feedback devices. Most feedback devices integrate the acceleration twice to estimate compression depth. However, they use additional sensors or processing techniques to compensate for large displacement drifts caused by integration. This study introduces an accelerometer-based method that avoids integration by using spectral techniques on short duration acceleration intervals. We used a manikin placed on a hard surface, a sternal triaxial accelerometer, and a photoelectric distance sensor (gold standard). Twenty volunteers provided 60 s of continuous compressions to test various rates (80-140 min(-1)), depths (3-5 cm), and accelerometer misalignment conditions. A total of 320 records with 35312 compressions were analysed. The global root-mean-square errors in rate and depth were below 1.5 min(-1) and 2 mm for analysis intervals between 2 and 5 s. For 3 s analysis intervals the 95% levels of agreement between the method and the gold standard were within -1.64-1.67 min(-1) and -1.69-1.72 mm, respectively. Accurate feedback on chest compression rate and depth is feasible applying spectral techniques to the acceleration. The method avoids additional techniques to compensate for the integration displacement drift, improving accuracy, and simplifying current accelerometer-based devices.