3 resultados para Russell, Malinda.

em Archivo Digital para la Docencia y la Investigación - Repositorio Institucional de la Universidad del País Vasco


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Screen-viewing has been associated with increased body mass, increased risk of metabolic syndrome and lower psychological well-being among children and adolescents. There is a shortage of information about the nature of contemporary screen-viewing amongst children especially given the rapid advances in screen-viewing equipment technology and their widespread availability. Anecdotal evidence suggests that large numbers of children embrace the multi-functionality of current devices to engage in multiple forms of screen-viewing at the same time. In this paper we used qualitative methods to assess the nature and extent of multiple forms of screen-viewing in UK children. Methods: Focus groups were conducted with 10-11 year old children (n = 63) who were recruited from five primary schools in Bristol, UK. Topics included the types of screen-viewing in which the participants engaged; whether the participants ever engaged in more than one form of screen-viewing at any time and if so the nature of this multiple viewing; reasons for engaging in multi-screen-viewing; the room within the house where multi-screen-viewing took place and the reasons for selecting that room. All focus groups were transcribed verbatim, anonymised and thematically analysed. Results: Multi-screen viewing was a common behaviour. Although multi-screen viewing often involved watching TV, TV viewing was often the background behaviour with attention focussed towards a laptop, handheld device or smart-phone. There were three main reasons for engaging in multi-screen viewing: 1) tempering impatience that was associated with a programme loading; 2) multi-screen facilitated filtering out unwanted content such as advertisements; and 3) multi-screen viewing was perceived to be enjoyable. Multi-screen viewing occurred either in the child's bedroom or in the main living area of the home. There was considerable variability in the level and timing of viewing and this appeared to be a function of whether the participants attended after-school clubs. Conclusions: UK children regularly engage in two or more forms of screen-viewing at the same time. There are currently no means of assessing multi-screen viewing nor any interventions that specifically focus on reducing multi-screen viewing. To reduce children's overall screen-viewing we need to understand and then develop approaches to reduce multi-screen viewing among children.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Quality of cardiopulmonary resuscitation (CPR) is key to increase survival from cardiac arrest. Providing chest compressions with adequate rate and depth is difficult even for well-trained rescuers. The use of real-time feedback devices is intended to contribute to enhance chest compression quality. These devices are typically based on the double integration of the acceleration to obtain the chest displacement during compressions. The integration process is inherently unstable and leads to important errors unless boundary conditions are applied for each compression cycle. Commercial solutions use additional reference signals to establish these conditions, requiring additional sensors. Our aim was to study the accuracy of three methods based solely on the acceleration signal to provide feedback on the compression rate and depth. Materials and Methods We simulated a CPR scenario with several volunteers grouped in couples providing chest compressions on a resuscitation manikin. Different target rates (80, 100, 120, and 140 compressions per minute) and a target depth of at least 50 mm were indicated. The manikin was equipped with a displacement sensor. The accelerometer was placed between the rescuer's hands and the manikin's chest. We designed three alternatives to direct integration based on different principles (linear filtering, analysis of velocity, and spectral analysis of acceleration). We evaluated their accuracy by comparing the estimated depth and rate with the values obtained from the reference displacement sensor. Results The median (IQR) percent error was 5.9% (2.8-10.3), 6.3% (2.9-11.3), and 2.5% (1.2-4.4) for depth and 1.7% (0.0-2.3), 0.0% (0.0-2.0), and 0.9% (0.4-1.6) for rate, respectively. Depth accuracy depended on the target rate (p < 0.001) and on the rescuer couple (p < 0.001) within each method. Conclusions Accurate feedback on chest compression depth and rate during CPR is possible using exclusively the chest acceleration signal. The algorithm based on spectral analysis showed the best performance. Despite these encouraging results, further research should be conducted to asses the performance of these algorithms with clinical data.