6 resultados para Reference electrodes

em Archivo Digital para la Docencia y la Investigación - Repositorio Institucional de la Universidad del País Vasco


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this article is to characterize dynamic optimal harvesting trajectories that maximize discounted utility assuming an age-structured population model, in the same line as Tahvonen (2009). The main novelty of our study is that uses as an age-structured population model the standard stochastic cohort framework applied in Virtual Population Analysis for fish stock assessment. This allows us to compare optimal harvesting in a discounted economic context with standard reference points used by fisheries agencies for long term management plans (e.g. Fmsy). Our main findings are the following. First, optimal steady state is characterized and sufficient conditions that guarantees its existence and uniqueness for the general case of n cohorts are shown. It is also proved that the optimal steady state coincides with the traditional target Fmsy when the utility function to be maximized is the yield and the discount rate is zero. Second, an algorithm to calculate the optimal path that easily drives the resource to the steady state is developed. And third, the algorithm is applied to the Northern Stock of hake. Results show that management plans based exclusively on traditional reference targets as Fmsy may drive fishery economic results far from the optimal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Single-species management objectives may not be consistent within mixed fisheries. They may lead species to unsafe situations, promote discarding of over-quota and/or misreporting of catches. We provide an algorithm for characterising bio-economic reference points for a mixed fishery as the steady-state solution of a dynamic optimal management problem. The optimisation problem takes into account: i) that species are fishing simultaneously in unselective fishing operations and ii)intertemporal discounting and fleet costs to relate reference points to discounted economic profits along optimal trajectories. We illustrate how the algorithm can be implemented by applying it to the European Northern Stock of Hake (Merluccius merluccius), where fleets also capture Northern megrim (Lepidorhombus whiffiagonis) and Northern anglerfish (Lophius piscatorius and Lophius budegassa). We find that optimal mixed management leads to a target reference point that is quite similar to the 2/3 of the Fmsy single-species (hake) target. Mixed management is superior to singlespecies management because it leads the fishery to higher discounted profits with higher long-term SSB for all species. We calculate that the losses due to the use of the Fmsy single-species (hake) target in this mixed fishery account for 11.4% of total discounted profits.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Functional Electrical Stimulation (FES) is a technique that consists on applying electrical current pulses to artificially activate motor nerve fibers and produce muscle contractions to achieve functional movements. The main applications of FES are within the rehabilitation field, in which this technique is used to aid recovery or to restore lost motor functions. People that benefit of FES are usually patients with neurological disorders which result in motor dysfunctions; most common patients include stroke and spinal cord injury (SCI). Neuroprosthesis are devices that have their basis in FES technique, and their aim is to bridge interrupted or damaged neural paths between the brain and upper or lower limbs. One of the aims of neuroprosthesis is to artificially generate muscle contractions that produce functional movements, and therefore, assist impaired people by making them able to perform activities of daily living (ADL). FES applies current pulses and stimulates nerve fibers by means of electrodes, which can be either implanted or surface electrodes. Both of them have advantages and disadvantages. Implanted electrodes need open surgery to place them next to the nerve root, so these electrodes carry many disadvantages that are produced by the use of invasive techniques. In return, as the electrodes are attached to the nerve, they make it easier to achieve selective functional movements. On the contrary, surface electrodes are not invasive and are easily attached or detached on the skin. Main disadvantages of surface electrodes are the difficulty of selectively stimulating nerve fibers and uncomfortable feeling perceived by users due to sensory nerves located in the skin. Electrical stimulation surface electrode technology has improved significantly through the years and recently, multi-field electrodes have been suggested. This multi-field or matrix electrode approach brings many advantages to FES; among them it is the possibility of easily applying different stimulation methods and techniques. The main goal of this thesis is therefore, to test two stimulation methods, which are asynchronous and synchronous stimulation, in the upper limb with multi-field electrodes. To this end, a purpose-built wrist torque measuring system and a graphic user interface were developed to measure wrist torque produced with each of the methods and to efficiently carry out the experiments. Then, both methods were tested on 15 healthy subjects and sensitivity results were analyzed for different cases. Results show that there are significant differences between methods regarding sensation in some cases, which can affect effectiveness or success of FES.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La fotovoltaica orgánica es una tecnología solar emergente que todavía no ha entrado en el mercado. El objetivo de esta tesis ha sido acercar un poco más la industrialización de dicha tecnología mediante el incremento de la eficiencia y la durabilidad de estos dispositivos solares. Para la consecución de dicho objetivo se identificaron las limitaciones existentes y se diseñó una hora de ruta con diversas estrategias para poder superar cada uno de los problemas. Así, mediante un exhaustivo control de la nano morfología del film fotoactivo y la introducción de electrodos nanoestructurados se ha conseguido incrementar la eficiencia. La sustitución de los electrodos estándares por nuevos electrodos basados en óxidos metálicos confiere durabilidad al sistema. Por último, la sustitución del óxido de indio y estaño como electrodo transparente por nanohilos metálicos de plata habilita la posibilidad de fabricar dispositivos solares flexibles de bajo coste.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Galaxies are clusters of millions and billions of stars dynamically stable, with gas, dust and dark matter. They are the biggest isolated objects known in the Universe . Even though they are very complex systems, today we have a clear knowledge about their evolution and about their physical phenomena. Aside from the stellar component there is a gaseous component, principally neutral Hydrogen (HI), and dust that, although is not a significant component in terms of the mass, plays an important role on the absorption phenomena. Finally, cinematic and other kind of observations suggest the existence of a spheric dark matter halo, dominant in terms of mass and more extensive than the barionic component.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Streptococcus pneumoniae serotype 6E has recently been described, but its long-term epidemiology is not well known. From 1981-2013, 704 serogroup 6 clinical isolates were obtained in Gipuzkoa, Basque Country, Spain. All invasive and one in four non-invasive isolates were included. Overall, 75, 97, 51 and 45 serotypes 6A, 6B, 6C and 6E isolates, respectively, were detected. No serotype 6D isolates were identified. The prevalence of serotypes 6E and 6B, but not that of serotypes 6A and 6C, declined after the introduction of pneumococcal conjugate vaccines. Serotype 6E isolates showed the highest resistance rate. Most serotype 6E isolates were ST90.