8 resultados para R-0

em Archivo Digital para la Docencia y la Investigación - Repositorio Institucional de la Universidad del País Vasco


Relevância:

60.00% 60.00%

Publicador:

Resumo:

[EN]Rumenic acid (cis9,trans11-18:2) is the main natural isomer of conjugated linoleic acid (CLA). Rumenic acid has many purported health benefits, but effects of most other CLA isomers are unknown. Typically trans7,cis9-18:2 is the second most abundant CLA isomer, but it co-elutes with rumenic acid on conventional polar gas chromatography (GC) columns, requiring complimentary analysis with silver-ion high performance liquid chromatography (Ag(+)-HPLC). Herein we report a rapid method for analyzing rumenic acid and trans7,cis9-18:2 using a 30 m ionic-liquid GC column. Optimal resolution of the two CLA isomers was at 145 degrees C and analysis of backfat from barley-fed cattle compared well with GC/Ag(+)-HPLC (y =0.978x - 0.031, r =0.985, P <0.001).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introducción: La medición de la concentración de hierro hepática (CHH) por RM es una técnica no invasiva de gran utilidad en el diagnóstico de los pacientes con sospecha de sobrecarga férrica en hígado. Objetivo:Validar la eficacia de la RM 1 Tesla en la determinación de la (CHH) en pacientes con sospecha de sobrecarga férrica. Validar su capacidad para diagnosticar o descartar la presencia de una CHH sugestiva de hemocromatosis. Pacientes y métodos:Estudio observacional, transversal, con inclusión prospectiva de pacientes consecutivos. De 2002 a 2010 hemos obtenido la CHH estimada mediante RM 1 Tesla (método Gandon) y de RM 1,5 Tesla (método Alústiza), y mediante BH, en 56 pacientes consecutivos (58RM:35/23). Resultados:Grupo RM 1 Tesla: de acuerdo con CHH en BH, 15 pacientes clasificados como normales (<36µmol/g)-la RM valoró correctamente 7; sobreestimó 8-; 15 grupo hemosiderosis (36-80 µmol/g)-RM valoró correctamente 5, sobreestimó 10-; 5 grupo hemocromatosis (>80 µmol/g)-valoró correctamente las 5-. Existió una correlación entre la determinación de la CHH por BH y RM 1 Tesla con r=0.619. Existieron diferencias estadísticamente significativas (p<0.05) entre CHH media por biopsia (53.43/DE45.67/IC95%37.74 a 69.12) y por RM 1 Tesla (76.14/DE47.31/IC95% 60.46 a 92.97), con sobrevaloración por parte de la RM. Grupo RM 1,5 Tesla: de acuerdo con CHH en BH, normal en 14, hemosiderosis en 6 y hemocromatosis en 3. La RM valoró correctamente 6 y sobreestimó 8 en grupo normal; grupo hemosiderosis, 3 correctamente, 3 sobrevalorados; grupo hemocromatosis, valoró correctamente los 3. La correlación entre CHH por BH y RM 1,5 Tesla fue de r=0.815. La CHH media obtenida por BH (69,34/DE152.1/IC95% 3.57 a 135.1 ) y RM 1,5 Tesla (70.43/DE 57.63/IC95% 45.51 a 95.36) no demostraron diferencias significativas (p>0.05). Conclusiones: La determinación de CHH por RM 1 Tesla (método Gandon) es útil para diagnosticar o descartar hemocromatosis y para diagnosticar CHH normal. Existe una importante tendencia a la sobreestimación en pacientes sin y con sobrecarga férrica en la CHH obtenida por RM 1 Tesla. La determinación de CHH por RM 1,5 Tesla (método Alústiza) es superior a la de RM 1 Tesla, aunque también existe una tendencia a sobreestimar. La CHH media obtenida por BH o RM 1,5 Tesla no tuvieron diferencias significativas. En cambio si existieron entre BH y RM 1 Tesla.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Resumen Background: Nitric oxide can be measured at multiple flow rates to determine proximal (maximum airway nitric oxide flux; Jaw(NO)) and distal inflammation (alveolar nitric oxide concentration; CA(NO)). The main aim was to study the association among symptoms, lung function, proximal (maximum airway nitric oxide flux) and distal (alveolar nitric oxide concentration) airway inflammation in asthmatic children treated and not treated with inhaled glucocorticoids. Methods: A cross-sectional study with prospective data collection was carried out in a consecutive sample of girls and boys aged between 6 and 16 years with a medical diagnosis of asthma. Maximum airway nitric oxide flux and alveolar nitric oxide concentration were calculated according to the two-compartment model. In asthmatic patients, the asthma control questionnaire (CAN) was completed and forced spirometry was performed. In controls, differences between the sexes in alveolar nitric oxide concentration and maximum airway nitric oxide flux and their correlation with height were studied. The correlation among the fraction of exhaled NO at 50 ml/s (FENO50), CA(NO), Jaw(NO), forced expiratory volume in 1 second (FEV1) and the CAN questionnaire was measured and the degree of agreement regarding asthma control assessment was studied using Cohen's kappa. Results: We studied 162 children; 49 healthy (group 1), 23 asthmatic participants without treatment (group 2) and 80 asthmatic patients treated with inhaled corticosteroids (group 3). CA(NO) (ppb) was 2.2 (0.1-4.5), 3 (0.2-9.2) and 2.45 (0.1-24), respectively. Jaw(NO) (pl/s) was 516 (98.3-1470), 2356.67 (120-6110) and 1426 (156-11805), respectively. There was a strong association (r = 0.97) between FENO50 and Jaw(NO) and the degree of agreement was very good in group 2 and was good in group 3. There was no agreement or only slight agreement between the measures used to monitor asthma control (FEV1, CAN questionnaire, CA(NO) and Jaw(NO)). Conclusions: The results for CA(NO) and Jaw(NO) in controls were similar to those found in other reports. There was no agreement or only slight agreement among the three measure instruments analyzed to assess asthma control. In our sample, no additional information was provided by CA(NO) and Jaw(NO).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objetivo: El objetivo de este estudio es analizar los diferentes métodos existentes para la cuantificación de la carga interna (CI) en el fútbol y estudiar las diferencias existentes en la CI en jóvenes jugadores élite de fútbol dependiendo de las características de las sesiones, equipo y puestos. Métodos: Se obtuvo la carga percibida, y la frecuencia cardiaca de 36 jóvenes jugadores élite (18,87 ± 1,24 años, masa:70,81 ± 5,62 kg) de las sesiones de entrenamiento realizadas durante tres semanas. Resultados: Las correlación encontrada entre el método de Edwards-TL y Stagno-TL fue de r=0,921 ± 0,126 entre Edwards-TL y el método de Foster r=0,47 ± 0,343 y entre el método de Stagno-TL y el método de Foster fue de r=0,451 ± 0,386. Los distintos indicadores, sRPE, Edwards-TL y Stagno-TL describen una CI similar en los diferentes tipos de sesión analizadas (Recuperación, Simulación, Resistencia, Fuerza y Velocidad) aunque no siempre coincidían. Siendo la sesión denominada Resistencia la que acumulaba más CI (172,68 ± 47,87; 76,01 ± 28,62y 445,49 ± 115,02 AU; Edwards-TL, Stagno-TL y Foster respectivamente). No se encontraron diferencias significativas en la CI dependiendo de los puestos jugadores, y solo se encontraron diferencias significativas entre los jugadores más veteranos y jóvenes en la carga percibida. Conclusiones: Los diferentes tipos de sesión suponen una CI diferente para los jugadores. Las diferencias existentes entre los tipos de sesión varían dependiendo del método de cuantificación utilizado. Los indicadores de CI basados en la FC y en la carga percibida no siempre pueden ser intercambiables y pueden aportar información distinta a los técnicos.