5 resultados para Positive displacement motors PDM

em Archivo Digital para la Docencia y la Investigación - Repositorio Institucional de la Universidad del País Vasco


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The problem discussed is the stability of two input-output feedforward and feedback relations, under an integral-type constraint defining an admissible class of feedback controllers. Sufficiency-type conditions are given for the positive, bounded and of closed range feed-forward operator to be strictly positive and then boundedly invertible, with its existing inverse being also a strictly positive operator. The general formalism is first established and the linked to properties of some typical contractive and pseudocontractive mappings while some real-world applications and links of the above formalism to asymptotic hyperstability of dynamic systems are discussed later on.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

6 p. Paper of the 17th Conference on Sensors and Their Applications held in Dubrovnik, Croatia. Sep 16-18, 2013

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Poor outcomes of invasive candidiasis (IC) are associated with the difficulty in establishing the microbiological diagnosis at an early stage. New scores and laboratory tests have been developed in order to make an early therapeutic intervention in an attempt to reduce the high mortality associated with invasive fungal infections. Candida albicans IFA IgG has been recently commercialized for germ tube antibody detection (CAGTA). This test provides a rapid and simple diagnosis of IC (84.4% sensitivity and 94.7% specificity). The aim of this study is to identify the patients who could be benefited by the use of CAGTA test in critical care setting. Methods: A prospective, cohort, observational multicentre study was carried out in six medical/surgical Intensive care units (ICU) of tertiary-care Spanish hospitals. Candida albicans Germ Tube Antibody test was performed twice a week if predetermined risk factors were present, and serologically demonstrated candidiasis was considered if the testing serum dilution was >= 1: 160 in at least one sample and no other microbiological evidence of invasive candidiasis was found. Results: Fifty-three critically ill non-neutropenic patients (37.7% post surgery) were included. Twenty-two patients (41.5%) had CAGTA-positive results, none of them with positive blood culture for Candida. Neither corrected colonization index nor antifungal treatment had influence on CAGTA results. This finding could corroborate that the CAGTA may be an important biomarker to distinguish between colonization and infection in these patients. The presence of acute renal failure at the beginning of the study was more frequent in CAGTA-negative patients. Previous surgery was statistically more frequent in CAGTA-positive patients. Conclusions: This study identified previous surgery as the principal clinical factor associated with CAGTA-positive results and emphasises the utility of this promising technique, which was not influenced by high Candida colonization or antifungal treatment. Our results suggest that detection of CAGTA may be important for the diagnosis of invasive candidiasis in surgical patients admitted in ICU.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A sliding mode position control for high-performance real-time applications of induction motors in developed in this work. The design also incorporates a simple flux estimator in order to avoid the flux sensors. Then, the proposed control scheme presents a low computational cost and therefore can be implemented easily in a real-time applications using a low cost DSP-processor. The stability analysis of the controller under parameter uncertainties and load disturbances in provided using Lyapunov stability theory. Finally, simulated and experimental results show that the proposed controller with the proposed observer provides a good trajectory tracking and that this scheme is robust with respect to plant parameter variations and external load disturbances.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Most wearable activity recognition systems assume a predefined sensor deployment that remains unchanged during runtime. However, this assumption does not reflect real-life conditions. During the normal use of such systems, users may place the sensors in a position different from the predefined sensor placement. Also, sensors may move from their original location to a different one, due to a loose attachment. Activity recognition systems trained on activity patterns characteristic of a given sensor deployment may likely fail due to sensor displacements. In this work, we innovatively explore the effects of sensor displacement induced by both the intentional misplacement of sensors and self-placement by the user. The effects of sensor displacement are analyzed for standard activity recognition techniques, as well as for an alternate robust sensor fusion method proposed in a previous work. While classical recognition models show little tolerance to sensor displacement, the proposed method is proven to have notable capabilities to assimilate the changes introduced in the sensor position due to self-placement and provides considerable improvements for large misplacements.