9 resultados para Feedback intervention
em Archivo Digital para la Docencia y la Investigación - Repositorio Institucional de la Universidad del País Vasco
Resumo:
Background: Little is known about the types of 'sit less, move more' strategies that appeal to office employees, or what factors influence their use. This study assessed the uptake of strategies in Spanish university office employees engaged in an intervention, and those factors that enabled or limited strategy uptake. Methods: The study used a mixed method design. Semi-structured interviews were conducted with academics and administrators (n = 12; 44 +/- 12 mean SD age; 6 women) at three points across the five-month intervention, and data used to identify factors that influenced the uptake of strategies. Employees who finished the intervention then completed a survey rating (n = 88; 42 +/- 8 mean SD age; 51 women) the extent to which strategies were used [never (1) to usually (4)]; additional survey items (generated from interviewee data) rated the impact of factors that enabled or limited strategy uptake [no influence (1) to very strong influence (4)]. Survey score distributions and averages were calculated and findings triangulated with interview data. Results: Relative to baseline, 67% of the sample increased step counts post intervention (n = 59); 60% decreased occupational sitting (n = 53). 'Active work tasks' and 'increases in walking intensity' were the strategies most frequently used by employees (89% and 94% sometimes or usually utilised these strategies); 'walk-talk meetings' and ` lunchtime walking groups' were the least used (80% and 96% hardly ever or never utilised these strategies). 'Sitting time and step count logging' was the most important enabler of behaviour change (mean survey score of 3.1 +/- 0.8); interviewees highlighted the motivational value of being able to view logged data through visual graphics in a dedicated website, and gain feedback on progress against set goals. 'Screen based work' (mean survey score of 3.2 +/- 0.8) was the most significant barrier limiting the uptake of strategies. Inherent time pressures and cultural norms that dictated sedentary work practices limited the adoption of 'walk-talk meetings' and ` lunch time walking groups'. Conclusions: The findings provide practical insights into which strategies and influences practitioners need to target to maximise the impact of 'sit less, move more' occupational intervention strategies.
Resumo:
11 p.
Resumo:
The stabilization of dynamic switched control systems is focused on and based on an operator-based formulation. It is assumed that the controlled object and the controller are described by sequences of closed operator pairs (L, C) on a Hilbert space H of the input and output spaces and it is related to the existence of the inverse of the resulting input-output operator being admissible and bounded. The technical mechanism addressed to get the results is the appropriate use of the fact that closed operators being sufficiently close to bounded operators, in terms of the gap metric, are also bounded. That philosophy is followed for the operators describing the input-output relations in switched feedback control systems so as to guarantee the closed-loop stabilization.
Resumo:
This paper presents a vaccination strategy for fighting against the propagation of epidemic diseases. The disease propagation is described by an SEIR (susceptible plus infected plus infectious plus removed populations) epidemic model. The model takes into account the total population amounts as a refrain for the illness transmission since its increase makes the contacts among susceptible and infected more difficult. The vaccination strategy is based on a continuous-time nonlinear control law synthesised via an exact feedback input-output linearization approach. An observer is incorporated into the control scheme to provide online estimates for the susceptible and infected populations in the case when their values are not available from online measurement but they are necessary to implement the control law. The vaccination control is generated based on the information provided by the observer. The control objective is to asymptotically eradicate the infection from the population so that the removed-by-immunity population asymptotically tracks the whole one without precise knowledge of the partial populations. The model positivity, the eradication of the infection under feedback vaccination laws and the stability properties as well as the asymptotic convergence of the estimation errors to zero as time tends to infinity are investigated.
Resumo:
105 p. : il. - Ilustraciones de Oscar Mardones Ruiz
Resumo:
[Es]En este trabajo se analiza la posibilidad de utilizar los sistemas de feedback comerciales más conocidos (TrueCPR de la empresa Physio-Control y CPRmeter de Laerdal) en un tren de larga distancia. Se trata de estudiar su habilidad y precisión tanto en profundidad de compresión como en frecuencia. Para nes comparativos, también ha sido necesario analizar la precisión de ambos equipos en condiciones de laboratorio.
Resumo:
Quality of cardiopulmonary resuscitation (CPR) improves through the use of CPR feedback devices. Most feedback devices integrate the acceleration twice to estimate compression depth. However, they use additional sensors or processing techniques to compensate for large displacement drifts caused by integration. This study introduces an accelerometer-based method that avoids integration by using spectral techniques on short duration acceleration intervals. We used a manikin placed on a hard surface, a sternal triaxial accelerometer, and a photoelectric distance sensor (gold standard). Twenty volunteers provided 60 s of continuous compressions to test various rates (80-140 min(-1)), depths (3-5 cm), and accelerometer misalignment conditions. A total of 320 records with 35312 compressions were analysed. The global root-mean-square errors in rate and depth were below 1.5 min(-1) and 2 mm for analysis intervals between 2 and 5 s. For 3 s analysis intervals the 95% levels of agreement between the method and the gold standard were within -1.64-1.67 min(-1) and -1.69-1.72 mm, respectively. Accurate feedback on chest compression rate and depth is feasible applying spectral techniques to the acceleration. The method avoids additional techniques to compensate for the integration displacement drift, improving accuracy, and simplifying current accelerometer-based devices.
Resumo:
167 p.
Resumo:
Background Quality of cardiopulmonary resuscitation (CPR) is key to increase survival from cardiac arrest. Providing chest compressions with adequate rate and depth is difficult even for well-trained rescuers. The use of real-time feedback devices is intended to contribute to enhance chest compression quality. These devices are typically based on the double integration of the acceleration to obtain the chest displacement during compressions. The integration process is inherently unstable and leads to important errors unless boundary conditions are applied for each compression cycle. Commercial solutions use additional reference signals to establish these conditions, requiring additional sensors. Our aim was to study the accuracy of three methods based solely on the acceleration signal to provide feedback on the compression rate and depth. Materials and Methods We simulated a CPR scenario with several volunteers grouped in couples providing chest compressions on a resuscitation manikin. Different target rates (80, 100, 120, and 140 compressions per minute) and a target depth of at least 50 mm were indicated. The manikin was equipped with a displacement sensor. The accelerometer was placed between the rescuer's hands and the manikin's chest. We designed three alternatives to direct integration based on different principles (linear filtering, analysis of velocity, and spectral analysis of acceleration). We evaluated their accuracy by comparing the estimated depth and rate with the values obtained from the reference displacement sensor. Results The median (IQR) percent error was 5.9% (2.8-10.3), 6.3% (2.9-11.3), and 2.5% (1.2-4.4) for depth and 1.7% (0.0-2.3), 0.0% (0.0-2.0), and 0.9% (0.4-1.6) for rate, respectively. Depth accuracy depended on the target rate (p < 0.001) and on the rescuer couple (p < 0.001) within each method. Conclusions Accurate feedback on chest compression depth and rate during CPR is possible using exclusively the chest acceleration signal. The algorithm based on spectral analysis showed the best performance. Despite these encouraging results, further research should be conducted to asses the performance of these algorithms with clinical data.