6 resultados para Crane, Charles Richard (1858-1939) -- Résidences et lieux familiers -- Massachusetts (États-Unis)

em Archivo Digital para la Docencia y la Investigación - Repositorio Institucional de la Universidad del País Vasco


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this thesis project, a building in Vegagatan 12, Gävle has been analysed in order to see why it does consume more energy than it was expected. This building is a low energy building certified by Miljöbyggnad and it should use less than 55kWh/m2 year and nowadays it is using 62.23 kWh/m2. To get the needed data, some information about the building has been gathered, some measurements have been done in the building and some calculations have been done with those measurements. Finally, some possible solutions have been offered to reduce the energy use of the building. Insulating the floor, the pipes and the walls, reducing the indoor temperature in winter... All of these changes need the help of environmentally friendly attitudes, which is a very important fact in low energy buildings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tesi hau Solarus AB enpresaren konzentratzailedun eguzki kolektore fotovoltaiko termikoei (C-PVT) buruz doa eta bi helburu nagusi ditu. Lehena Solarus-eko oraingo diseinuaren alderaketak diseinatzea da, MaReCo (Maximum Reflector Collector) diseinuaren eta parabola puruaren alderaketa batzuekin batera. Diseinu hauetan eguzki zelulen ebaketa berriak daude barruan eta 4 busbar-eko eguzki zeluletan oinarritua dago. Honi esker analisi sakon bat egin ahalko da hargailu eta estruktura diseinuak konparatuz. Bigarren helburua Solarus AB-k Gävleko unibertsitatean (HiG) kokaturik dituen kolektoreen errendimendu elektriko eta termikoa aztertzean datza. Datuak simulazio eta software espezifikoen bidez lortu dira eta ondoren Microsoft Excel®-en aztertu. Bi proiektu txikiagoak egin dira ere enpresan, bata eguzki kolektore fotovoltaiko termikoen merkatuaren ikerketan datza eta bestea eguzki kolektoreen produkzio prozesuaren gida batean. Hargailuen eta estrukturaren diseinu berriak preparatuta utzi dira prototipoen hurreneko eraikuntzarako eta proiektuarekin jarraitzeko etorkizuneko lan bat planeatu da. Unibertsitateko instalakuntzaren analisiari dagokionez, errendimendu elektriko eta termikoa estimatuena baino nabarmenki txikiagoak izan dira.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

(English)The Swedish industrial sector has overcome the oil crisis and has maintained the energy use constant even though the production has grown. This has been achieved thanks to the development of several energy policies, by the Swedish government, towards the 2020 goals. This thesis carries on this path and performs an energy audit for an old industrial building in Gävle (Sweden) in order to propose different energy efficiency measures to use less energy while maintaining the thermal comfort. The building is in quite a bad shape and some of the areas are unused making them a waste of money. By means of the invoices provided by different companies, the information from the staff and some measures that have been carried out in-situ, the energy balance has been calculated from where conclusions have been drawn. Although it is an industrial building, the study is not going to be focused in the industrial process but in the building’s envelope and support processes, since the unit combines both production and office areas. Therefore, the energy balance is divided in energy supplies (district heating, free heating and sun irradiation) and energy losses (transmission, ventilation hot tap water and infiltrations). The results show that the most important supply is that of the DH whereas the most important losses are the transmission and infiltration. Thus, the measures proposed are focused on the reduction of this relevant parameters. The most important measures are the renovation of the windows, heating systems valves and the ventilation. The glazing of the dwelling is old and some of it is broken accounting for quite a large amount of the losses. The radiator valves are not properly working and there does not exist any temperature control. Therefore the installation of thermostatic valves turns out to be a must. Moreover, some part of the building has no mechanical ventilation but conserves the ducts. These could be utilized if they are connected to the workshop’s ventilation which is capable of generating sufficient flow for the entire building. Finally, although other measures could also be carried out, the ones proposed appear to be the essential ones. A further analysis should be carried out in order to analyze the payback time or investment capability of the company so as to decide between one measure or another. A market study for possible new tenants for the unused parts of the building is also advisable.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nowadays, Power grids are critical infrastructures on which everything else relies, and their correct behavior is of the highest priority. New smart devices are being deployed to be able to manage and control power grids more efficiently and avoid instability. However, the deployment of such smart devices like Phasor Measurement Units (PMU) and Phasor Data Concentrators (PDC), open new opportunities for cyber attackers to exploit network vulnerabilities. If a PDC is compromised, all data coming from PMUs to that PDC is lost, reducing network observability. Our approach to solve this problem is to develop an Intrusion detection System (IDS) in a Software-defined network (SDN). allowing the IDS system to detect compromised devices and use that information as an input for a self-healing SDN controller, which redirects the data of the PMUs to a new, uncompromised PDC, maintaining the maximum possible network observability at every moment. During this research, we have successfully implemented Self-healing in an example network with an SDN controller based on Ryu controller. We have also assessed intrinsic vulnerabilities of Wide Area Management Systems (WAMS) and SCADA networks, and developed some rules for the Intrusion Detection system which specifically protect vulnerabilities of these networks. The integration of the IDS and the SDN controller was also successful. \\To achieve this goal, the first steps will be to implement an existing Self-healing SDN controller and assess intrinsic vulnerabilities of Wide Area Measurement Systems (WAMS) and SCADA networks. After that, we will integrate the Ryu controller with Snort, and create the Snort rules that are specific for SCADA or WAMS systems and protocols.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

[ES] Junto con formas simples de restitución y compensación, se han detectado variantes de las primeras prácticas de justicia restaurativa en las antiguas civilizaciones de Israel, Sumeria, Babilonia y Roma y entre los pueblos aborígenes de Norteamérica y Oceanía. Por su parte, en el siglo XX, principalmente en respuesta a la ola criminal de los años 60 y 70, y buscando alternativas a los métodos tradicionales de tratamiento de los delitos de esa época, comenzaron a emerger programas experimentales que usaban los principios de justicia restaurativa a comienzos de los 70 en Canadá, Estados Unidos, Inglaterra, Australia y Nueva Zelanda.