2 resultados para Control measures

em Archivo Digital para la Docencia y la Investigación - Repositorio Institucional de la Universidad del País Vasco


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper deals with the convergence of a remote iterative learning control system subject to data dropouts. The system is composed by a set of discrete-time multiple input-multiple output linear models, each one with its corresponding actuator device and its sensor. Each actuator applies the input signals vector to its corresponding model at the sampling instants and the sensor measures the output signals vector. The iterative learning law is processed in a controller located far away of the models so the control signals vector has to be transmitted from the controller to the actuators through transmission channels. Such a law uses the measurements of each model to generate the input vector to be applied to its subsequent model so the measurements of the models have to be transmitted from the sensors to the controller. All transmissions are subject to failures which are described as a binary sequence taking value 1 or 0. A compensation dropout technique is used to replace the lost data in the transmission processes. The convergence to zero of the errors between the output signals vector and a reference one is achieved as the number of models tends to infinity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Resumen Background: Nitric oxide can be measured at multiple flow rates to determine proximal (maximum airway nitric oxide flux; Jaw(NO)) and distal inflammation (alveolar nitric oxide concentration; CA(NO)). The main aim was to study the association among symptoms, lung function, proximal (maximum airway nitric oxide flux) and distal (alveolar nitric oxide concentration) airway inflammation in asthmatic children treated and not treated with inhaled glucocorticoids. Methods: A cross-sectional study with prospective data collection was carried out in a consecutive sample of girls and boys aged between 6 and 16 years with a medical diagnosis of asthma. Maximum airway nitric oxide flux and alveolar nitric oxide concentration were calculated according to the two-compartment model. In asthmatic patients, the asthma control questionnaire (CAN) was completed and forced spirometry was performed. In controls, differences between the sexes in alveolar nitric oxide concentration and maximum airway nitric oxide flux and their correlation with height were studied. The correlation among the fraction of exhaled NO at 50 ml/s (FENO50), CA(NO), Jaw(NO), forced expiratory volume in 1 second (FEV1) and the CAN questionnaire was measured and the degree of agreement regarding asthma control assessment was studied using Cohen's kappa. Results: We studied 162 children; 49 healthy (group 1), 23 asthmatic participants without treatment (group 2) and 80 asthmatic patients treated with inhaled corticosteroids (group 3). CA(NO) (ppb) was 2.2 (0.1-4.5), 3 (0.2-9.2) and 2.45 (0.1-24), respectively. Jaw(NO) (pl/s) was 516 (98.3-1470), 2356.67 (120-6110) and 1426 (156-11805), respectively. There was a strong association (r = 0.97) between FENO50 and Jaw(NO) and the degree of agreement was very good in group 2 and was good in group 3. There was no agreement or only slight agreement between the measures used to monitor asthma control (FEV1, CAN questionnaire, CA(NO) and Jaw(NO)). Conclusions: The results for CA(NO) and Jaw(NO) in controls were similar to those found in other reports. There was no agreement or only slight agreement among the three measure instruments analyzed to assess asthma control. In our sample, no additional information was provided by CA(NO) and Jaw(NO).