2 resultados para Non-uniform heat intensity
em Universita di Parma
Resumo:
The efficiency of a Laue lens for X and Gamma ray focusing in the energy range 60 ÷ 600 keV is closely linked to the diffraction efficiency of the single crystals composing the lens. A powerful focusing system is crucial for applications like medical imaging and X ray astronomy where wide beams must be focused. Mosaic crystals with a high density, such as Cu or Au, and bent crystals with curved diffracting planes (CDP) are considered for the realization of a focusing system for X rays, owing to their high diffraction efficiency. In this work, a comparison of the efficiency of CDP crystals and mosaic crystals was performed on the basis of the theory of X-ray diffraction. Si, GaAs and Ge CDP crystals with optimized thicknesses and moderate radii of curvature of several tens of metres demonstrate comparable or superior performance with respect to the higher atomic number mosaic crystals generally used. A simplified approach for calculating the integrated reflectivity of the crystals is applied. A bending technique used during this work to realize CDP crystals consists in a controlled surface damaging induced by a mechanical lapping process. A compressive strained layer of few micrometres in thickness is generated and causes the convex curvature of the damaged side of the crystal. Another new bending technique is developed and the main results are shown. The process consists on a film deposition of a selected bi-component epoxy resin on one side of crystal, made uniform in thickness by mean of a spin-coater. Choosing the speed of spin-coating, so changing the thickness of the film, a control of radius of curvature can be obtained. Moreover the possibility to combine the two bending technique to obtain CDP crystal with a stronger curvature in rather thick crystals was demonstrated. Detailed characterization of Si, and GaAs CDP crystals at low and high x-ray energies are performed on flat and bent crystals obtained with the damaging and the resin deposition technique. As expected an increase of diffraction efficiency in asymmetrical diffraction geometry in CDP crystals with respect to the flat ones is observed. On the other hand an unexpected increase of the integrated intensity in symmetrical geometry, not predicted by the theory, is observed in all the measurements performed with different set up. The experimental trend of the integrated reflectivity as a function of the radius of curvature is in a good agreement with that predicted by the theory of bent perfect crystals, so it is possible to conclude that the surface damage has a limited effect on the crystal reflectivity. A study of the integrated reflectivity in the energy range of interest (100÷350 keV) in CDP crystals realized with damaging and resin deposition technique at symmetrical and asymmetrical geometries was performed at ILL Institute. Also at these energies the diffraction efficiency of bent crystals was much larger (a 12 time increase is observed for bent crystals in asymmetrical 111 geometry) than that measured in flat crystals. The diffraction efficiency of CDP crystals realized with both techniques tends to coincide with that of flat crystals at very high energies (> 200 keV). This suggesting that also real flat perfect crystals can be considered as strongly bent or mosaic crystals at very high X ray energies.
Resumo:
The aim of this thesis was to validate the use of infrared thermography (IRT) to non-invasively measure emotional reactions to different situations in pet dogs (Canis familiaris). A preliminary test, aimed to evaluate the correlation between eye-temperature and rectal temperature in dog, was performed. Then, in three different situations, negative (veterinary visit), positive (palatable food rewards), and mildly stressing followed by mildly positive (separation from and reunion with the owner), variations in heat emitted from lacrimal caruncle (referred to as eye temperature) were measured with an infrared thermographic camera. In addition, heart rate and heart rate variability parameters were collected using a non-invasive heart rate monitor designed for human use and validated on dogs. All experiments were video recorded to allow behavioral coding. During the negative situation dogs’ level of activity and stress related behaviors varied across compared to the baseline and dogs showed an increase in eye temperature despite having a significant decrease in the level of activity. The positive situation was characterized by a peak in eye temperature and mean HR and dogs engaged in behaviors indicating a positive arousal, focusing on food treats and tail wagging but there were not variations in HRV during stimulation but only an increment in SDNN immediately after the stimulus. In the separation from and reunion with the owner dogs’ eye temperature and mean HR did not vary neither in the stressful nor in the positive situations, RMSSD increased after the positive episode, SDNN dropped during the two stimulations and it increased after the stimulations. During the separation from the owner dogs were mainly directed to the door or to the experimenter while during the reunion with the owner dogs were focused mainly on the owner and on the environment, exhibiting safe base effect. A different approach was used to assess the welfare of shelter dogs. Dogs were implanted with a telemeter and after implantation dogs were housed in sequence in four different situations lasting 1 week: alone, alone with toys and a stretch cot for sleeping, with an unknown, spayed, female, and alone with a daily 2-hours interaction with an experimenter. Two different approaches were tried: partially random extracted fragments from every week, behaviors from 8 a.m. to 4 p.m. were continuous during baseline and the female situation. Results showed different reactions by dogs to the different situations and interestingly not all enrichments were enjoyed by the dogs improving their welfare. Overall results suggest that IRT may represent a useful tool to investigate emotional reactions in dogs. Nevertheless, further research is needed to establish the specificity and sensivity of IRT in this context and to assess how different dogs’ characteristics, breed, previous experience and the valence and arousal elicited by the stimulus could influence the magnitude and type of the response. The role of HRV in understanding emotional valence and the one of telemeters in understanding long-term effects on sheltered dogs’ welfare is also discussed.