2 resultados para thermal spike model

em Aquatic Commons


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Observations of Caspian Sea during August - September 1995 are used to develop a three dimensional numerical for calculating temperature and current. This period was chosen because of extensive set of observational data including surface temperature observations. Data from the meteorological buoy network on Caspian Sea are combined with routine observation at first order synoptic station around the lake to obtain hourly values of wind stress and pressure fields. Initial temperature distribution as a function of depth and horizontal coordinates are derived from ship cruises. The model has variable grid resolution and horizontal smoothing which filters out small scale vertical motion. The hydrodynamic model of Caspian Sea has 6 vertical levels and a uniform horizontal grid size of 50 km The model is driven with surface fluxes of heat and momentum derived from observed meteorological. The model was able to reproduce all of the basic feature of the thermal structure in Caspian sea and: larger scale circulation patterns tend to be cyclone, with cyclone circulation with each sub basin. Result has agreement with observations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this study, thermal, exergetic analysis and performance evaluation of seawater and fresh wet cooling tower and the effect of parameters on its performance is investigated. With using of energy and mass balance equations, experimental results, a mathematical model and EES code developed. Due to lack of fresh water, seawater cooling is interesting choice for future of cooling, so the effect of seawater in the range of 1gr/kg to 60gr/kg for salinity on the performance characteristics like air efficiency, water efficiency, output water temperature of cooling tower, flow of the exergy, and the exergy efficiency with comparison with fresh water examined. Decreasing of air efficiency about 3%, increasing of water efficiency about 1.5% are some of these effects. Moreover with formation of fouling the performance of cooling tower decreased about 15% which this phenomena and its effects like increase in output water temperature and tower excess volume has been showed and also accommodate with others work. Also optimization for minimizing cost, maximizing air efficiency, and minimizing exergy destruction has been done, results showed that optimization on minimizing the exergy destruction has been satisfy both minimization of the cost and the maximization of the air efficiency, although it will not necessarily permanent for all inputs and optimizations. Validation of this work is done by comparing computational results and experimental data which showed that the model have a good accuracy.