2 resultados para seawater neutralization

em Aquatic Commons


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The general purpose of this study is to investigate the degree of heavy metal accumulation in hard and soft tissue of sea urchin, and determining these tissues as the most suitable bioindicator for lead and cadmium in the environment of the sampling stations. The way of doing this assessment was MOOPAM. Samples were prepared and classified according to sea urchin organ (soft tissue, hard tissue, Tube feet, Test, Lantern Structure and spines) and then lead and cadmium were measured in them. Result of this study shows that hard tissue is a better index of lead and cadmium than soft tissue. The result of bioaccumulation of lead in the related tissue was found to be in the following order: Soft tissue=21, hard tissue=28.1, Test=20.8, Lantern Structure=20.5 and spines=23.9. The result of bioaccumulation of cadmium in the related tissue was found to be in the following order: Soft tissue=9. 7, hard tissue=5.01, Test=4.2, Lantern Structure=4.06 and spines=5.53.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, thermal, exergetic analysis and performance evaluation of seawater and fresh wet cooling tower and the effect of parameters on its performance is investigated. With using of energy and mass balance equations, experimental results, a mathematical model and EES code developed. Due to lack of fresh water, seawater cooling is interesting choice for future of cooling, so the effect of seawater in the range of 1gr/kg to 60gr/kg for salinity on the performance characteristics like air efficiency, water efficiency, output water temperature of cooling tower, flow of the exergy, and the exergy efficiency with comparison with fresh water examined. Decreasing of air efficiency about 3%, increasing of water efficiency about 1.5% are some of these effects. Moreover with formation of fouling the performance of cooling tower decreased about 15% which this phenomena and its effects like increase in output water temperature and tower excess volume has been showed and also accommodate with others work. Also optimization for minimizing cost, maximizing air efficiency, and minimizing exergy destruction has been done, results showed that optimization on minimizing the exergy destruction has been satisfy both minimization of the cost and the maximization of the air efficiency, although it will not necessarily permanent for all inputs and optimizations. Validation of this work is done by comparing computational results and experimental data which showed that the model have a good accuracy.