Resumo:

The instrument described in this report is an updated version of the high precision, automated Winkler titration system described by Friederich et al.(1984). The original instrument was based on the work of Bryan et al. (1976) who developed a colorimetric endpoint detector and on the work of Williams and Jenkinson (1982) who produced an automated system that used this detector. The goals of our updated version of the device described by Friederich et al. (1984) were as follows: 1) Move control of the system to the MS-DOS environment because HP-85 computers are no longer in production and because more user-friendly programs could be written using the IBM XT or AT computers that control the new device. 2) Use more "off the shelf" components and reduce the parts count in the new system so that it could be easily constructed and maintained. This report describes how to construct and use the new automated Winkler titration device. It also includes information on the chemistry of the Winkler titration, and detailed instructions on how to prepare reagents, collect samples, standardize and perform the titrations (Appendix I: Codispoti, L.A. 1991 On the determination of dissolved oxygen in sea water, 15pp.). A disk containing the program needed to operate the new device is also included. (pdf contains 33 pages)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

CHAP 1 - Introduction to the Guide CHAP 2 - Solution chemistry of carbon dioxide in sea water CHAP 3 - Quality assurance CHAP 4 - Recommended standard operating procedures (SOPs) SOP 1 - Water sampling for the parameters of the oceanic carbon dioxide system SOP 2 - Determination of total dissolved inorganic carbon in sea water SOP 3a - Determination of total alkalinity in sea water using a closed-cell titration SOP 3b - Determination of total alkalinity in sea water using an open-cell titration SOP 4 - Determination of p(CO2) in air that is in equilibrium with a discrete sample of sea water SOP 5 - Determination of p(CO2) in air that is in equilibrium with a continuous stream of sea water SOP 6a - Determination of the pH of sea water using a glass/reference electrode cell SOP 6b - Determination of the pH of sea water using the indicator dye m-cresol purple SOP 7 - Determination of dissolved organic carbon and total dissolved nitrogen in sea water SOP 7 en Español - Determinacion de carbono organico disuelto y nitrogeno total disuelto en agua de mar SOP 11 - Gravimetric calibration of the volume of a gas loop using water SOP 12 - Gravimetric calibration of volume delivered using water SOP 13 - Gravimetric calibration of volume contained using water SOP 14 - Procedure for preparing sodium carbonate solutions for the calibration of coulometric CT measurements SOP 21 - Applying air buoyancy corrections SOP 22 - Preparation of control charts SOP 23 - Statistical techniques used in quality assessment SOP 24 - Calculation of the fugacity of carbon dioxide in the pure gas or in air CHAP 5 - Physical and thermodynamic data Errata - to the hard copy of the Guide to best practices for ocean CO2 measurements

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Salinity, temperature and pressure are parameters which govern the oceanographic state of a marine water body and together they make up density of seawater. In this contribution we will focus our interest on one of these parameters, the salinity: accuracy in relation to different purposes as well as observation technique and instrumentation. We will also discuss the definition of salinity. For example most of the Indian Ocean waters are within the salinity range from 34.60-34.80, which emphasize the importance of careful observations and clear definitions of salinity, in such a way that it is possible to define water masses and predict their movements. In coastal waters the salinity usually features much larger variation in time and space and thus less accuracy is sometimes needed. Salinity has been measured and defined in several ways over the past century. While early measurements were based on the amount of salt in a sea water sample, today the salinity of seawater is most often determined from its conductivity. As conductivity is a function of salinity and temperature, determination involves also measurement of the density of seawater is now more precisely estimated and thus the temperature. As a result of this method the Practical Salinity Scale (PSS) was developed. The best determination of salinity from conductivity and the temperature measurements gives salinity with resolution of 0.001 psu, while the accuracy of titration method was about ± 0.02‰. Because of that, even calculation of movements in the ocean is also improved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Salinity, temperature and pressure are parameters which govern the oceanographic state of a marine water body and together they make up density of seawater. In this contribution we will focus our interest on one of these parameters, the salinity: accuracy in relation to different purposes as well as observation technique and instrumentation. We will also discuss the definition of salinity. For example most of the Indian Ocean waters are within the salinity range from 34.60-34.80, which emphasize the importance of careful observations and clear definitions of salinity, in such a way that it is possible to define water masses and predict their movements. In coastal waters the salinity usually features much larger variation in time and space and thus less accuracy is sometimes needed. Salinity has been measured and defined in several ways over the past century. While early measurements were based on the amount of salt in a sea water sample, today the salinity of seawater is most often determined from its conductivity. As conductivity is a function of salinity and temperature, determination involves also measurement of the density of seawater is now more precisely estimated and thus the temperature. As a result of this method the Practical Salinity Scale (PSS) was developed. The best determination of salinity from conductivity and the temperature measurements gives salinity with resolution of 0.001 psu, while the accuracy of titration method was about ± 0.02‰. Because of that, even calculation of movements in the ocean is also improved.