4 resultados para Flow meters

em Aquatic Commons


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The Alliance for Coastal Technologies (ACT) held a Workshop on Sensor Technology for Assessing Groundwater-Surface Water Interactions in the Coastal Zone on March 7 to 9,2005 in Savannah, GA. The main goal of the workshop was to summarize the general parameters, which have been found to be useful in assessing groundwater-surface water (GW-SW) interactions in the coastal zone. The workshop participants (Appendix I) were specifically charged with identifying the types of sensor systems, if any, that have been used to obtain time-series data and to make known which parameters may be the most amenable to the development/application of sensor technology. The group consisted of researchers, industry representatives, and environmental managers. Four general recommendations were made: 1. Educate coastal managers and agencies on the importance of GW-SW interactions, keeping in mind that regulatory agencies are driven by a different set of rules than researchers: the focus is on understanding the significance of the problem and providing solutions. ACT could facilitate this process in two ways. First, given that the research literature on this subject is fairly diffuse, ACT could provide links from its web site to fact sheets or other literature. Second, ACT could organize a focused meeting for managers and/or agency groups. Encourage development of primary tools for quantifying flow. The most promising technology in this respect is flow meters designed for flux chambers, mainly because they should be simple to use and can be made relatively inexpensively. However, it should be kept in mind that they provide only point measurements and several would need to be deployed as a network in order to obtain reliable flow estimates. For evaluating system wide GW-SW interactions, tools that integrate the signal over large areas would be required. Suggestions include a user-friendly hydrogeologic models, keeping in mind that freshwater flow is not the entire story, or continuous radon monitors. Though the latter would be slightly more difficult to use in terms of background knowledge, such an instrument would be low power and easy to operate and maintain. ACT could facilitate this recommendation by identifying funding opportunities on its web site and/or performing evaluations of existing technologies that could be summarized on the web site. (pdf contains 18 pages)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A winch suitable for lowering and hauling up of costly hydrographic apparatus like Bathy-thermograph, Reversible thermometers, Current flow meters etc., was designed, fabricated and tested at Off Shore Fishing Station, Cochin. The first model of this winch is in use on board the motor vessel Pratap, a Tuna Long linger.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Two large hydrologic issues face the Kings Basin, severe and chronic overdraft of about 0.16M ac-ft annually, and flood risks along the Kings River and the downstream San Joaquin River. Since 1983, these floods have caused over $1B in damage in today’s dollars. Capturing flood flows of sufficient volume could help address these two pressing issues which are relevant to many regions of the Central Valley and will only be exacerbated with climate change. However, the Kings River has high variability associated with flow magnitudes which suggests that standard engineering approaches and acquisition of sufficient acreage through purchase and easements to capture and recharge flood waters would not be cost effective. An alternative approach investigated in this study, termed On-Farm Flood Flow Capture, involved leveraging large areas of private farmland to capture flood flows for both direct and in lieu recharge. This study investigated the technical and logistical feasibility of best management practices (BMPs) associated with On-Farm Flood Flow Capture. The investigation was conducted near Helm, CA, about 20 miles west of Fresno, CA. The experimental design identified a coordinated plan to determine infiltration rates for different soil series and different crops; develop a water budget for water applied throughout the program and estimate direct and in lieu recharge; provide a preliminary assessment of potential water quality impacts; assess logistical issues associated with implementation; and provide an economic summary of the program. At check locations, we measured average infiltration rates of 4.2 in/d for all fields and noted that infiltration rates decreased asymptotically over time to about 2 – 2.5 in/d. Rates did not differ significantly between the different crops and soils tested, but were found to be about an order of magnitude higher in one field. At a 2.5 in/d infiltration rate, 100 acres are required to infiltrate 10 CFS of captured flood flows. Water quality of applied flood flows from the Kings River had concentrations of COC (constituents of concern; i.e. nitrate, electrical conductivity or EC, phosphate, ammonium, total dissolved solids or TDS) one order of magnitude or more lower than for pumped groundwater at Terranova Ranch and similarly for a broader survey of regional groundwater. Applied flood flows flushed the root zone and upper vadose zone of nitrate and salts, leading to much lower EC and nitrate concentrations to a depth of 8 feet when compared to fields in which more limited flood flows were applied or for which drip irrigation with groundwater was the sole water source. In demonstrating this technology on the farm, approximately 3,100 ac-ft was diverted, primarily from April through mid-July, with about 70% towards in lieu and 30% towards direct recharge. Substantial flood flow volumes were applied to alfalfa, wine grapes and pistachio fields. A subset of those fields, primarily wine grapes and pistachios, were used primarily to demonstrate direct recharge. For those fields about 50 – 75% of water applied was calculated going to direct recharge. Data from the check studies suggests more flood flows could have been applied and infiltrated, effectively driving up the amount of water towards direct recharge. Costs to capture flood flows for in lieu and direct recharge for this project were low compared to recharge costs for other nearby systems and in comparison to irrigating with groundwater. Moreover, the potentially high flood capture capacity of this project suggests significant flood avoidance costs savings to downstream communities along the Kings and San Joaquin Rivers. Our analyses for Terranova Ranch suggest that allocating 25% or more flood flow water towards in lieu recharge and the rest toward direct recharge will result in an economically sustainable recharge approach paid through savings from reduced groundwater pumping. Two important issues need further consideration. First, these practices are likely to leach legacy salts and nitrates from the unsaturated zone into groundwater. We develop a conceptual model of EC movement through the unsaturated zone and estimated through mass balance calculations that approximately 10 kilograms per square meter of salts will be flushed into the groundwater through displacing 12 cubic meters per square meter of unsaturated zone pore water. This flux would increase groundwater salinity but an equivalent amount of water added subsequently is predicted as needed to return to current groundwater salinity levels. All subsequent flood flow capture and recharge is expected to further decrease groundwater salinity levels. Second, the project identified important farm-scale logistical issues including irrigator training; developing cropping plans to integrate farming and recharge activities; upgrading conveyance; and quantifying results. Regional logistical issues also exist related to conveyance, integration with agricultural management, economics, required acreage and Operation and Maintenance (O&M).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Persian Gulf region is globally of great importance due to its economical and political reasons. The importance lies in oil sources and sea exports. Geophysical phenomena dominated in the water circulation affected this region is called Monsoon it stretches from African coasts to the half way of Red Seal affected all coasts of Persian Gulf and goes toward east to the Indian ocean. Other essential factors in the water circulation in this region are net evaporation (several meters in per year), high density and high salinity. In this article the effects of wind stress and evaporation in the water circulation in the region will be considered and model equations for wind forces, density, pressure, gradient, and bottom friction for Persian Gulf will be discussed.