4 resultados para Dip coating
em Aquatic Commons
Resumo:
This report summarises the findings of a series of electric-fishing surveys carried out at four sites on the River Ribble from September 1997 to September 1998. The aims of these surveys were to assess the impact on juvenile salmonids of a pollution incident involving Synthetic Pyrethrin (SP) that occurred near High Birkwith I (SD 802 767) in September 1997.One of these sites was 2.65km upstream of the pollution whilst the remaining three were at varying distances downstream. Data was collected during surveys of the River Ribble in 1992, 97 and 98. The 1997 and 1998 surveys were carried out specifically to monitor for any possible effects of the SP discharge. Data are shown as grades derived from the National Fisheries Classification scheme (NFC). Results are given for the four salmonid life stages; 0+ trout, >0+ trout, 0+ salmon, >0+ salmon and also Total Salmonids.
Resumo:
Prawn, crab and clam meat were processed in experimental ca s having reduced internal tin coating of 5.6 GSM. Conventional cans having 11.2 GSM tin coating were used as control. Results showed that experimental cans behaved normally when used for canning prawns, provided the lacquer film was perfect with no exposure of metal. When there was a discontinuity in lacquer film exposing the metal blackening took place in such areas. Areas subjected to severe strains like the lock seam side and expansion rings on can ends were found to be more prone to blackening. Experimental cans were found unsuitable for canning crab meat or clam meat because in both cases the can wall as well as the contents underwent discoloration, in all cases.
Resumo:
In this study, the effect of anti-corrosion inhibitor addition to epoxy coating, on the disbanding rate was evaluated. First to determination of mechanism, the bare steel substrates were immersed in the 3.5% NaCl solution and the solution containing 1 mM anti corrosion. The Electrochemical Impedance Spectroscopy was performed after 5 and 24 hour. The results indicated a lower corrosion rate in the presence of inhibitor. During the time, charge transfer resistance, was decreased for the substrates immersed in NaCl solution, and increased for the substrates immersed in NaCl solution containing 1 mM anti corrosion. This result can be related to more stability of corrosion products in presence of anti-corrosion and film formation. The coated substrates, with four different concentration of anticorrosion in coating, were protected under -1.2 voltage in the 3.5% NaCl solution. After 12 and 24 hour, the EIS test and disbanding area measurement, were evaluate. The lower disbanding rate, more charge transfer resistance and less double layer capacitance for the coating containing 0.75w% inhibitor, were observed. The result of Pull-off test after 1 day immersion in 3.5% NaCl solution, showed more wet adhesion for the coating containing 0.75w% inhibitor. The images of FE-SEM electron microscope and surface analyses EDX on the coated substrate after disbanding and the bare substrate immersed in 3.5w% NaCl containing 1 mM inhibitor, were proved the formation of stabilized film.