5 resultados para Cooling system design
em Aquatic Commons
Resumo:
Today , Providing drinking water and process water is one of the major problems in most countries ; the surface water often need to be treated to achieve necessary quality, and in this way, technological and also financial difficulties cause great restrictions in operating the treatment units. Although water supply by simple and cheap systems has been one of the important objectives in most scientific and research centers in the world, still a great percent of population in developing countries, especially in rural areas, don't benefit well quality water. One of the big and available sources for providing acceptable water is sea water. There are two ways to treat sea water first evaporation and second reverse osmosis system. Nowadays R.O system has been used for desalination because of low budget price and easily to operate and maintenance. The sea water should be pretreated before R.O plants, because there is some difficulties in raw sea water that can decrease yield point of membranes in R.O system. The subject of this research may be useful in this way, and we hope to be able to achieve complete success in design and construction of useful pretreatment systems for R.O plant. One of the most important units in the sea water pretreatment plant is filtration, the conventional method for filtration is pressurized sand filters, and the subject of this research is about new filtration which is called continuous back wash sand filtration (CBWSF). The CBWSF designed and tested in this research may be used more economically with less difficulty. It consists two main parts first shell body and second central part comprising of airlift pump, raw water feeding pipe, air supply hose, backwash chamber and sand washer as well as inlet and outlet connections. The CBWSF is a continuously operating filter, i.e. the filter does not have to be taken out of operation for backwashing or cleaning. Inlet water is fed through the sand bed while the sand bed is moving downwards. The water gets filtered while the sand becomes dirty. Simultaneously, the dirty sand is cleaned in the sand washer and the suspended solids are discharged in backwash water. We analyze the behavior of CBWSF in pretreatment of sea water instead of pressurized sand filter. There is one important factor which is not suitable for R.O membranes, it is bio-fouling. This factor is defined by Silt Density Index (SDI).measured by SDI. In this research has been focused on decreasing of SDI and NTU. Based on this goal, the prototype of pretreatment had been designed and manufactured to test. The system design was done mainly by using the design fundamentals of CBWSF. The automatic backwash sand filter can be used in small and also big water supply schemes. In big water treatment plants, the units of filters perform the filtration and backwash stages separately, and in small treatment plants, the unit is usually compacted to achieve less energy consumption. The analysis of the system showed that it may be used feasibly for water treating, especially for limited population. The construction is rapid, simple and economic, and its performance is high enough because no mobile mechanical part is used in it, so it may be proposed as an effective method to improve the water quality and consequently the hygiene level in the remote places of the country.
Resumo:
Fishlocks at Salto Grande Reservoir. Considerations about its functioning. The Salto Grande dam, has in its structure two Borland type fishlocks. The fish passage efficiency is low, and it is limited by the original system design, the management of the dam and the Uruguay river hidrology. Thus, in the 1984-1986 period, on annual average, the fishlocks were out of service 53 o/o of the time, while in the two periods when higher observed fish accumulation occur, march-april and september-october, the passages were closed 72 o/o and 54 o/o of the time, respectively. (PDF has 55 pages.)
Resumo:
In selecting an excess temperature at which to operate a power plant cooling system it has been customary to consider only thermal stresses and to use the ratio of the number of organisms killed to the number of organisms entrained. This frequently leads to the selection of a low excess temperature, AT, which, in turn, requires a large volume flow of cooling water. When mortalities due to physical and chemical stresses are included and the total number of entrained organisms killed is taken as the measure of the environmental damage, it becomes evident that the choice of a low excess temperature is seldom, if ever, best.
Resumo:
(pdf contains 418 pages)
Resumo:
This contribution is the first part of a four-part series documenting the development of B:RUN, a software program which reads data for common spreadsheets and presents them as low-resolution maps of slates and processes. The program emerged from a need which arose during a project in Brunei Darussalam for a 'low level' approach for researchers to communicate findings as efficiently and expeditiously as possible. Part I provides a overview of the concept and design elements of B:RUN. Part II will highlight results of the economics components of the program evaluating different fishing regimes, sailing distances from ports and fleet operating costs. Environmental aspects will be presented in Part III in the form of overlay maps. Part IV will summarize the implications of B:RUN results to coastal and fishery resources management in Brunei Darussalam and show how this approach can be adapted to other coastlines and used as a teaching and training tool. The following three parts will be published in future editions of Naga, the ICLARM Quarterly. The program is available through ICLARM.