30 resultados para Calibration measurements

em Aquatic Commons


Relevância:

30.00% 30.00%

Publicador:

Resumo:

CHAP 1 - Introduction to the Guide CHAP 2 - Solution chemistry of carbon dioxide in sea water CHAP 3 - Quality assurance CHAP 4 - Recommended standard operating procedures (SOPs) SOP 1 - Water sampling for the parameters of the oceanic carbon dioxide system SOP 2 - Determination of total dissolved inorganic carbon in sea water SOP 3a - Determination of total alkalinity in sea water using a closed-cell titration SOP 3b - Determination of total alkalinity in sea water using an open-cell titration SOP 4 - Determination of p(CO2) in air that is in equilibrium with a discrete sample of sea water SOP 5 - Determination of p(CO2) in air that is in equilibrium with a continuous stream of sea water SOP 6a - Determination of the pH of sea water using a glass/reference electrode cell SOP 6b - Determination of the pH of sea water using the indicator dye m-cresol purple SOP 7 - Determination of dissolved organic carbon and total dissolved nitrogen in sea water SOP 7 en Español - Determinacion de carbono organico disuelto y nitrogeno total disuelto en agua de mar SOP 11 - Gravimetric calibration of the volume of a gas loop using water SOP 12 - Gravimetric calibration of volume delivered using water SOP 13 - Gravimetric calibration of volume contained using water SOP 14 - Procedure for preparing sodium carbonate solutions for the calibration of coulometric CT measurements SOP 21 - Applying air buoyancy corrections SOP 22 - Preparation of control charts SOP 23 - Statistical techniques used in quality assessment SOP 24 - Calculation of the fugacity of carbon dioxide in the pure gas or in air CHAP 5 - Physical and thermodynamic data Errata - to the hard copy of the Guide to best practices for ocean CO2 measurements

Relevância:

30.00% 30.00%

Publicador:

Resumo:

New technologies can be riddled with unforeseen sources of error, jeopardizing the validity and application of their advancement. Bioelectrical impedance analysis (BIA) is a new technology in fisheries research that is capable of estimating proximate composition, condition, and energy content in fish quickly, cheaply, and (after calibration) without the need to sacrifice fish. Before BIA can be widely accepted in fisheries science, it is necessary to identify sources of error and determine a means to minimize potential errors with this analysis. We conducted controlled laboratory experiments to identify sources of errors within BIA measurements. We concluded that electrode needle location, procedure deviations, user experience, time after death, and temperature can affect resistance and reactance measurements. Sensitivity analyses showed that errors in predictive estimates of composition can be large (>50%) when these errors are experienced. Adherence to a strict protocol can help avoid these sources of error and provide BIA estimates that are both accurate and precise in a field or laboratory setting.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The band-by-band vicarious calibration of on-orbit satellite ocean color instruments, such as SeaWiFS and MODIS, using ground-based measurements has significant residual uncertainties. This paper applies spectral shape and population statistics to tune the calibration of the blue bands against each other to allow examination of the interband calibration and potentially provide an analysis of calibration trends. This adjustment does not require simultaneous matches of ground and satellite observations. The method demonstrates the spectral stability of the SeaWiFS calibration and identifies a drift in the MODIS instrument onboard Aqua that falls within its current calibration uncertainties.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A study was conducted on a small pond in southeast Texas to evaluate the potential for using remote sensing technology to assess feeding damage on giant salvinia ( Salvinia molesta Mitchell) by the salvinia weevil ( Cyrtobagous salviniae Calder and Sands). Field spectral measurements showed that moderately damaged and severely damaged plants had lower visible and near-infrared reflectance values than healthy plants. Healthy, moderately damaged, and severely damaged giant salvinia plants could be differentiated in an aerial color-infrared photograph of the study site. Computer analysis of the photograph showed that the three damage level classes could be quantified. (PDF has 5 pages.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This technical memorandum reports on the noise measurement results performed on MBARI's Ventana ROV. The measurement procedure and the instrumentation for this experiment are also described. This report is organized as follows: Section 1 provides some introductory information. Section 2 describes the experiment and the instrumentation. Section 3 presents the results. Section 4 contains some concluding remarks. (PDF contains 16 pages.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Alliance for Coastal Technologies (ACT) Workshop "Making Oxygen Measurements Routine Like Temperature" was convened in St. Petersburg, Florida, January 4th - 6th, 2006. This event was sponsored by the University of South Florida (USF) College of Marine Science, an ACT partner institution and co-hosted by the Ocean Research Interactive Observatory Networks (ORION). Participants from researcldacademia, resource management, industry, and engineering sectors collaborated with the aim to foster ideas and information on how to make measuring dissolved oxygen a routine part of a coastal or open ocean observing system. Plans are in motion to develop large scale ocean observing systems as part of the US Integrated Ocean Observing System (100s; see http://ocean.us) and the NSF Ocean Observatory Initiative (001; see http://www.orionprogram.org/00I/default.hl). These systems will require biological and chemical sensors that can be deployed in large numbers, with high reliability, and for extended periods of time (years). It is also likely that the development cycle for new sensors is sufficiently long enough that completely new instruments, which operate on novel principles, cannot be developed before these complex observing systems will be deployed. The most likely path to development of robust, reliable, high endurance sensors in the near future is to move the current generation of sensors to a much greater degree of readiness. The ACT Oxygen Sensor Technology Evaluation demonstrated two important facts that are related to the need for sensors. There is a suite of commercially available sensors that can, in some circumstances, generate high quality data; however, the evaluation also showed that none of the sensors were able to generate high quality data in all circumstances for even one month time periods due to biofouling issues. Many groups are attempting to use oxygen sensors in large observing programs; however, there often seems to be limited communication between these groups and they often do not have access to sophisticated engineering resources. Instrument manufacturers also do not have sufficient resources to bring sensors, which are marketable, but of limited endurance or reliability, to a higher state of readiness. The goal of this ACT/ORION Oxygen Sensor Workshop was to bring together a group of experienced oceanographers who are now deploying oxygen sensors in extended arrays along with a core of experienced and interested academic and industrial engineers, and manufacturers. The intended direction for this workshop was for this group to exchange information accumulated through a variety of sensor deployments, examine failure mechanisms and explore a variety of potential solutions to these problems. One anticipated outcome was for there to be focused recommendations to funding agencies on development needs and potential solutions for 02 sensors. (pdf contains 19 pages)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A three day workshop on turbidity measurements was held at the Hawaii Institute of Marine Biology from August 3 1 to September 2, 2005. The workshop was attended by 30 participants from industry, coastal management agencies, and academic institutions. All groups recognized common issues regarding the definition of turbidity, limitations of consistent calibration, and the large variety of instrumentation that nominally measure "turbidity." The major recommendations, in order of importance for the coastal monitoring community are listed below: 1. The community of users in coastal ecosystems should tighten instrument design configurations to minimize inter-instrument variability, choosing a set of specifications that are best suited for coastal waters. The IS0 7027 design standard is not tight enough. Advice on these design criteria should be solicited through the ASTM as well as Federal and State regulatory agencies representing the majority of turbidity sensor end users. Parties interested in making turbidity measurements in coastal waters should develop design specifications for these water types rather than relying on design standards made for the analysis of drinking water. 2. The coastal observing groups should assemble a community database relating output of specific sensors to different environmental parameters, so that the entire community of users can benefit from shared information. This would include an unbiased, parallel study of different turbidity sensors, employing a variety of designs and configuration in the broadest range of coastal environments. 3. Turbidity should be used as a measure of relative change in water quality rather than an absolute measure of water quality. Thus, this is a recommendation for managers to develop their own local calibrations. See next recommendation. 4. If the end user specifically wants to use a turbidity sensor to measure a specific water quality parameter such as suspended particle concentration, then direct measurement of that water quality parameter is necessary to correlate with 'turbidity1 for a particular environment. These correlations, however, will be specific to the environment in which they are measured. This works because there are many environments in which water composition is relatively stable but varies in magnitude or concentration. (pdf contains 22 pages)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Alliance for Coastal Technology (ACT) convened a workshop on the in situ measurement of dissolved inorganic carbon species in natural waters in Honolulu, Hawaii, on February 16, 17, and 18, 2005. The workshop was designed to summarize existing technologies for measuring the abundance and speciation of dissolved inorganic carbon and to make strategic recommendations for future development and application of these technologies to coastal research and management. The workshop was not focused on any specific technology, however, most of the attention of the workshop was on in situ pC02 sensors given their recent development and use on moorings for the measurement of global carbon fluxes. In addition, the problems and limitations arising from the long-term deployment of systems designed for the measurement of pH, total dissolved inorganic carbon (DIC), and total alkalinity (TA) were discussed. Participants included researchers involved in carbon biogeochemistry, industry representatives, and coastal resource managers. The primary questions asked during the workshop were: I. What are the major impediments to transform presently used shipboard pC02 measurement systems for use on cost-eficient moorings? 2. What are the major technical hurdles for the in situ measurement of TA and DIC? 3. What specific information do we need to coordinate efforts for proof of concept' testing of existing and new technologies, inter-calibration of those technologies, better software development, and more precise knowledge quantzjjing the geochemistry of dissolved inoeanic carbon species in order to develop an observing system for dissolved inorganic carbon? Based on the discussion resulting from these three questions, the following statements were made: Statement No. 1 Cost-effective, self-contained technologies for making long-term, accurate measurements of the partial pressure of C02 gas in water already exist and at present are ready for deployment on moorings in coastal observing systems. Statement No. 2 Cost-effective, self-contained systems for the measurement of pH, TA, and DIC are still needed to both fully define the carbonate chemistry of coastal waters and the fluxes of carbon between major biogeochemical compartments (e.g., air-sea, shelf-slope, water column-sediment, etc.). (pdf contains 23 pages)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Alliance for Coastal Technologies (ACT) Workshop "Applications of in situ Fluorometers in Nearshore Waters" was held in Cape Elizabeth, Maine, February 2-4,2005, with sponsorship by the Gulf of Maine Ocean Observing System (GoMOOS), one of the ACT partner organization. The purpose of the workshop was to explore recent trends in fluorometry as it relates to resource management applications in nearshore environments. Participants included representatives from state and federal environmental management agencies as well as research institutions, many of whom are currently using this technology in their research and management applications. Manufacturers and developers of fluorometric measuring systems also attended the meeting. The Workshop attendees discussed the historical and present uses of fluorometry technology and identified the great potential for its use by coastal managers to fulfill their regulatory and management objectives. Participants also identified some of the challenges associated with the correct use of Fluorometers to estimate biomass and the rate of primary productivity. The Workshop concluded that in order to expand the existing use of fluorometers in both academic and resource management disciplines, several issues concerning data collection, instrument calibration, and data interpretation needed to be addressed. Participants identified twelve recommendations, the top five of which are listed below: Recommendations 1) Develop a "Guide" that describes the most important aspects of fluorescence measurements. This guide should be written by an expert party, with both research and industry input, and should be distributed by all manufacturers with their instrumentation. The guide should also be made available on the ACT website as well as those of other relevant organizations. The guide should include discussions on the following topics: The benefits of using fluorometers in research and resource management applications; What fluorometers can and cannot provide in terms of measurements; The necessary assumptions required before applying fluorometry; Characterization and calibration of fluorometers; (pdf contains 32 pages)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Elkhorn Slough was first exposed to direct tidal forcing from the waters of Monterey Bay with the construction of Moss Landing Harbor in 1946. Elkhorn Slough is located mid-way between Santa Cruz and Monterey close to the head of Monterey Submarine Canyon. It follows a 10 km circuitous path inland from its entrance at Moss Landing Harbor. Today, Elkhorn Slough is a habitat and sanctuary for a wide variety of marine mammals, fish, and seabirds. The Slough also serves as a sink and pathway for various nutrients and pollutants. These attributes are directly or indirectly affected by its circulation and physical properties. Currents, tides and physical properties of Elkhorn Slough have been observed on an irregular basis since 1970. Based on these observations, the physical characteristics of Elkhorn Slough are examined and summarized. Elkhorn Slough is an ebb-dominated estuary and, as a result, the rise and fall of the tides is asymmetric. The fact that lower low water always follows higher high water and the tidal asymmetry produces ebb currents that are stronger than flooding currents. The presence of extensive mud flats and Salicornia marsh contribute to tidal distortion. Tidal distortion also produces several shallow water constituents including the M3, M4, and M6 overtides and the 2MK3 and MK3 compound tides. Tidal elevations and currents are approximately in quadrature; thus, the tides in Elkhorn Slough have some of the characters of a standing wave system. The temperature and salinity of lower Elkhorn Slough waters reflect, to a large extent, the influence of Monterey Bay waters, whereas the temperature and salinity of the waters of the upper Slough (>5 km from the mouth) are more sensitive to local processes. During the summer, temperature and salinity are higher in the upper slough due to local heating and evaporation. Maximum tidal currents in Elkhorn Slough have increased from approximately 75 to 120 cm/s over the past 30 years. This increase in current speed is primarily due to the change in tidal prism which has increased from approximately 2.5 to 6.2 x 106 m3 between 1956 and 1993. The increase in tidal prism is the result of both 3 rapid man-made changes to the Slough, and the continuing process of tidal erosion. Because of the increase in the tidal prism, the currents in Elkhorn Slough exhibit positive feedback, a process with uncertain consequences. [PDF contains 55 pages]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The population of eastern oyster, C. virginica, has declined over the last century on most areas of the east and gulf coasts. North Carolina’s restoration efforts depend on the construction of subtidal oyster reefs to be used as broodstock sanctuaries in Pamlico Sound, NC. Successful restoration of the oyster population requires several thriving reefs connected as a meta-population. C. virginica has a 2-3 week larval stage, during which it gradually settles through the water column. Larvae that can travel from one reef to another during that stage form the basis of a meta-population. (PDF contains 3 pages)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A total of 61 specimens of Heterotis niloticus were evaluated by linear regression and correlation. The specimens had mean standard length of 27.09 plus or minus 4.73cm, total length of 33-49cm, mean weight of 2445,108.3g, mean snout length of 48 plus or minus 0.86cm, mean eye diameter of 1.30 plus or minus 0.15cm, mean head length of 6.29 plus or minus 1.75cm. There was a strong relationship between the length and the weight, the eye diameter and the standard length, snout length and the standard length, head length and the standard length, snout length and the weight, head length and the weight (P<0.05). But the correlation of the eye diameters and the weight was insignificant (P>0.05). The growth pattern analysis depicts that the growth was negatively allometric with a b value of 1.16

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Adjustment of experimental channels to give any specified pattern of water depth or velocity is complex and tedious because it involves a number of variables. Since some variables are not controllable and variables may interact, valve settings of the Grassholme channels were initially determined on an ad hoc basis to suit individual experiments. This method was used during 1982 but additional observations were made in order to gain more detailed understanding of the channel system and, as far as possible, to develop a guide to future short-cuts in attaining suitable channel settings for any given purpose. This report describes calibration of the Grassholme channels (using water of the Grassholme Reservoir) for the biological experiments of spring - summer 1982. The main variables that are discussed are valve turns and discharge and velocity and depth. It also seeks to establish relationships which will be of value in future managment of the channels for experimental purposes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

(1) A total of 45 sites was sampled, each being fished using the semi-quantitative and quantitative techniques. (2) A significant relationship existed between the semi-quantitative and Quantitative results for all age groups of salmonids (R2 83.4% to 96.1%, p < 0.0001). (3) The results from each site were categorised according to an existing classification system for quantitative and semi-quantitative data. The semi-quantitative component of this system was modified using the results of this investigation. The degree of error associated with sites classified semi-quantitatively was found to be slightly less when using the modified system for 0+ salmon, > 0+ salmon and 0+ trout, ranging from 10.5% to 30%. (4) Insufficient data points were available for the analysis of coarse fish data.