3 resultados para Absolute configuration
em Aquatic Commons
Resumo:
A three day workshop on turbidity measurements was held at the Hawaii Institute of Marine Biology from August 3 1 to September 2, 2005. The workshop was attended by 30 participants from industry, coastal management agencies, and academic institutions. All groups recognized common issues regarding the definition of turbidity, limitations of consistent calibration, and the large variety of instrumentation that nominally measure "turbidity." The major recommendations, in order of importance for the coastal monitoring community are listed below: 1. The community of users in coastal ecosystems should tighten instrument design configurations to minimize inter-instrument variability, choosing a set of specifications that are best suited for coastal waters. The IS0 7027 design standard is not tight enough. Advice on these design criteria should be solicited through the ASTM as well as Federal and State regulatory agencies representing the majority of turbidity sensor end users. Parties interested in making turbidity measurements in coastal waters should develop design specifications for these water types rather than relying on design standards made for the analysis of drinking water. 2. The coastal observing groups should assemble a community database relating output of specific sensors to different environmental parameters, so that the entire community of users can benefit from shared information. This would include an unbiased, parallel study of different turbidity sensors, employing a variety of designs and configuration in the broadest range of coastal environments. 3. Turbidity should be used as a measure of relative change in water quality rather than an absolute measure of water quality. Thus, this is a recommendation for managers to develop their own local calibrations. See next recommendation. 4. If the end user specifically wants to use a turbidity sensor to measure a specific water quality parameter such as suspended particle concentration, then direct measurement of that water quality parameter is necessary to correlate with 'turbidity1 for a particular environment. These correlations, however, will be specific to the environment in which they are measured. This works because there are many environments in which water composition is relatively stable but varies in magnitude or concentration. (pdf contains 22 pages)
Resumo:
Three experiments were performed in an estuarine squid-trawl fishery in New South Wales, Australia, to test modifications to trawl nets. Lateral mesh openings were experimentally increased and physical bycatch reduction devices (BRDs) were placed in codends. These modifications aimed to reduce nontargeted catches of fish, while maintaining catches of the targeted broad squid (Photololigo etheridgei) and bottle squid (Loliolus noctiluca). Compared to conventional codends made with 41-mm diamond mesh, codends made with different posterior circumferences and larger 45-mm mesh had no significant effect on the catches of any species. The best performing configurations involved the installation of BRDs designed to separate organisms according to differences in behavior. In particular, versions of a composite square-mesh panel reduced the total weight of bycatch by up to 71% and there was no significant effect on the catches of squid. The results are discussed in terms of the probable differences in behavior between fish and squid in codends. After this study, a square-mesh panel BRD was voluntarily adopted throughout the fishery.