22 resultados para Low-Cost Sensor
Resumo:
The study was conducted in collaboration with the ECFC project of the FAO (BGD/97/017) in Cox's Bazar to develop a low cost solar tunnel dryer for the production of high quality marine dried fish. The study areas were Kutubdiapara, Maheshkhali and Shahparirdip under Cox's Bazar district. Three different models of low cost solar dryer were constructed with locally available materials such as bamboo, wood, bamboo mat, hemp, canvas, wire, nails, rope, tin, polythene and net. Size of the dryers were: 20x4x3 ft ; 30x3x3 ft and 65x3x3 ft with the costs of Tk. 3060, 3530, 9600 for dryer 1, 2 and 3, respectively having different models. The drying capacities were 50, 150, 500 kg for dryer 1, 2 and 3 respectively. The average temperature range inside the dryers were 29-43°C, 34-51°C and 37-57°C for dryer 1, 2 and 3 respectively as recorded at 8:30h to 16:30h. The relative humidity were in the ranges of 22-42%, 27-39% and 24-41 % in dryer 1, 2 and 3 respectively. The fish samples used were Bombay duck, Silver Jew fish and Ribbon fish. The total drying time was in the range of 30-42, 28-38 and 24-34 hours to reach the moisture content of 12.3-14.5, 11.8-14.3, and 11.6-14.1% in dryer 1, 2 and 3 respectively. Among these three fish samples the drying was faster in Silver Jew fish followed by Bombay duck and Ribbon fish in all the three dryer.
Resumo:
An experiment was conducted to evaluate the effects of control of carbon/nitrogen ratio (C/N ratio) by addition of low cost carbohydrate to the water column on water quality and pond ecology in freshwater prawn Macrobrachium rosenbergii post-larvae nursing system. In this experiment, two level of dietary protein 20% and 35% without carbohydrate addition (‘P20' and ‘P35') and with carbohydrate addition (‘P20+CH' and ‘P35+CH') were compared in small ponds of 40 m² area stocked with 20 post-larvae (0.021 ± 0.001g) per m² . Maize flour was used as low cost carbohydrate and applied to the water column followed by the first feeding during the day. The addition of carbohydrate significantly reduced (p< 0.05) ammonia-nitrogen (NH sub(3)-N) and nitrite-nitrogen (NO sub(2) - N) of water in P20 + CH and P35 + CH treatments. It significantly increased (p< 0.05) the total heterotrophic bacteria (THB) population both in water and sediment. Fifty nine genera of plankton were identified belonging to the Bacillariophyceae (11), Chlorophyceae (21), Cyanophyceae (7), Dinophyceae (1), Rotifera (7) and Crustacea (9) without any significant difference (p>0.05) of total phytoplankton and zooplankton among the treatments. Survival rate of prawn was significantly lowest (p<0.05) in P20 and no significant difference (p>0.05) was observed between P20+CH and P35 treatments. Control of C/N ratio by the addition of low-cost carbohydrate to the pond water column benefited the freshwater prawn nursing practices in three ways (1) increased heterotrophic bacterial growth supplying bacterial protein augment the prawn post-larvae growth performances, (2) reduced demand for supplemental feed protein and subsequent reduction in feed cost and (3) reduced toxic NH sub(3)-N and NO sub(2)-N levels in pond nursing system.
Resumo:
Studies were conducted on the organoleptic, biochemical and bacteriological aspects of three dried fish products produced from two different model of low cost solar tunnel dryer. The overall quality of the products obtained from both dryers was excellent. Sixty minutes soaking showed the maximum water reconstitution of the products with values between 66.82 to 75.28% and 71.98 to 78.09% in dryer 1 & 2 respectively. The highest reconstitution was obtained from Silver Jew fish (75.28-78.09%) and lowest from Bombay duck (66.86-71.98%) from both dryers. The average moisture, protein, lipid and ash content of the dried products were 11.8-15.0%, 57.32-68.49%, 6.08-8.62% and 12.25-14.88% respectively in fish in dryer 1 and dryer 2. The TVB-N values were in the range of 24.3 to 30.9 in dryer 1 and 22.1 to 28.2 mg/100 g samples in dryer 2. The highest values were obtained from Bombay duck and lowest value in Silver Jew fish in both dryers. The peroxide values varied from 14.1 to 16.9% in dryer 1 and 13.3 to 16.4% in dryer 2. The highest peroxide value was obtained from Ribbon fish and lowest from Silver Jew fish. Total bacterial load varied in the range of 6.6x10⁴— 8.6x10⁴ CFU/g in dryer 1 and 2.54x10⁴ to 4.9x10⁴ CFU/g in dryer 2. The highest value was obtained from Ribbon fish and lowest from Silver Jew fish.
Production of quality dried small indigenous fish species products using low cost solar tunnel drier
Resumo:
A low cost solar drier was constructed using locally available materials. The size of the drier was 20x3.6x3 having drying capacity of 80 kg of SIS (w/w). Optimization of moisture content was observed for mola, dhela, chapila, chanda and puti at temperature ranges between 40-45°C and 50-55°C in solar tunnel drier. There was little or no change in moisture content at temperature below 40°C during the first 3 hours. Then the moisture content declined gradually with the increase of drying period. On the other hand, at temperature between 50-55°C, moisture content started to decline after 2 hours of drying. The moisture content of the sample reached at about 16% after 26 hours of sun drying at 40-45°C and 20 hours at 50-55°C. The optimum temperature for producing high quality dried products was 45-50°C in solar tunnel drier. The temperature and relative humidity outside and inside the dryers (with fish) at various locations were recorded from 8.00am to 4.00pm. The normal atmospheric ambient temperature was recorded in the range of 25-37°C from at 8:00am to 4:00pm. During the same period the atmospheric relative humidity recorded was in the range of 30-58%. On the other hand, the maximum temperature inside the dryers was recorded in the range of 28-65°C. The lowest temperature recorded was 28°C in the morning and at 13.00pm the highest temperature 65°C was recorded. The maximum relative humidity 58% found in the afternoon and minimum of 28% at noon. There was inverse relationship between temperature intensity of sunshine and humidity which decreased as sunshine increased. In total, it took around 26 hours of drying to reduce the moisture level to about 16%.
Resumo:
This Alliance for Coastal Technologies (ACT) workshop was convened to assess the availability and state of development of conductivity-temperature sensors that can meet the needs of coastal monitoring and management communities. Rased on the discussion, there are presently a number of commercial sensor options available, with a wide range of package configurations suitable for deployment in a range of coastal environments. However, some of the central questions posed in the workshop planning documents were left somewhat unresolved. The workshop description emphasized coastal management requirements and, in particular, whether less expensive, easily deployed, lower-resolution instruments might serve many management needs. While several participants expressed interest in this class of conductivity-temperature sensors, based on input from the manufacturers, it is not clear that simply relaxing the present level of resolution of existing instruments will result in instruments of significantly lower unit cost. Conductivity-temperature sensors are available near or under the $1,000 unit cost that was operationally defined at the workshop as a breakpoint for what might be considered to be a "low cost" sensor. For the manufacturers, a key consideration before undertaking the effort to develop lower cost sensors is whether there will be a significant market. In terms of defining "low cost," it was also emphasized that the "life cycle costs" for a given instrument must be considered (e.g., including personnel costs for deployment and maintenance). An adequate market survey to demonstrate likely applications and a viable market for lower cost sensors is needed. Another topic for the workshop was the introduction to the proposed ACT verification for conductivity-temperature sensors. Following a summary of the process as envisioned by ACT, initial feedback was solicited. Protocol development will be pursued further in a workshop involving ACT personnel and conductivity-temperature sensor manufacturers.[PDF contains 28 pages]
Resumo:
The use of self-contained, low-maintenance sensor systems installed on commercial vessels is becoming an important monitoring and scientific tool in many regions around the world. These systems integrate data from meteorological and water quality sensors with GPS data into a data stream that is automatically transferred from ship to shore. To begin linking some of this developing expertise, the Alliance for Coastal Technologies (ACT) and the European Coastal and Ocean Observing Technology (ECOOT) organized a workshop on this topic in Southampton, United Kingdom, October 10-12, 2006. The participants included technology users, technology developers, and shipping representatives. They collaborated to identify sensors currently employed on integrated systems, users of this data, limitations associated with these systems, and ways to overcome these limitations. The group also identified additional technologies that could be employed on future systems and examined whether standard architectures and data protocols for integrated systems should be established. Participants at the workshop defined 17 different parameters currently being measured by integrated systems. They identified that diverse user groups utilize information from these systems from resource management agencies, such as the Environmental Protection Agency (EPA), to local tourism groups and educational organizations. Among the limitations identified were instrument compatibility and interoperability, data quality control and quality assurance, and sensor calibration andlor maintenance frequency. Standardization of these integrated systems was viewed to be both advantageous and disadvantageous; while participants believed that standardization could be beneficial on many levels, they also felt that users may be hesitant to purchase a suite of instruments from a single manufacturer; and that a "plug and play" system including sensors from multiple manufactures may be difficult to achieve. A priority recommendation and conclusion for the general integrated sensor system community was to provide vessel operators with real-time access to relevant data (e.g., ambient temperature and salinity to increase efficiency of water treatment systems and meteorological data for increased vessel safety and operating efficiency) for broader system value. Simplified data displays are also required for education and public outreach/awareness. Other key recommendations were to encourage the use of integrated sensor packages within observing systems such as 100s and EuroGOOS, identify additional customers of sensor system data, and publish results of previous work in peer-reviewed journals to increase agency and scientific awareness and confidence in the technology. Priority recommendations and conclusions for ACT entailed highlighting the value of integrated sensor systems for vessels of opportunity through articles in the popular press, and marine science. [PDF contains 28 pages]
Resumo:
A Low-Level Geographic Information System (LL-GIS) was developed to provide a simple low-cost mapping program which can be executed in any personal computer, by individuals with different levels of knowledge in computing. MAPPER is an add-on module of FishBase - a global database with key information on the biology of fish - where it creates on-screen maps with information on biodiversity and the occurrence of species. In another application, MAPPER is used to display and analyzed geographical information on the Philippines.