17 resultados para NMR spectra
Resumo:
In view of recent interest in the Cl37 (ʋ solar’e-)Ar37 reaction cross section, information on some aspects of mass 37 nuclei has been obtained using the K39 (d, ∝) Ar37 and Cl35 (He3, p) Ar37 reactions. Ar37 levels have been found at 0, 1.41, 1.62, 2.22, 2.50, 2.80, 3.17, 3.27, 3.53, 3.61, 3.71, (3.75), (3.90), 3.94, 4.02, (4.21), 4.28, 4.32, 4.40, 4.45, 4.58, 4.63, 4.74, 4.89, 4.98, 5.05, 5.10, 5.13, 5.21, 5.35, 5.41, 5.44, 5.54, 5.58, 5.67, 5.77, and 5.85 MeV (the underlined values correspond to previously tabulated levels). The nuclear temperature calculated from the Ar37 level density is 1.4 MeV. Angular distributions of the lowest six levels with the K39 (d, ∝) Ar37 reaction at Ed = 10 MeV indicate a dominant direct interaction mechanism and the inapplicability of the 2I + 1 rule of the statistical model. Comparison of the spectra obtained with the K39 (d, ∝) Ar37 and Cl35 (He3, p) Ar37 reactions leads to the suggestion that the 5.13-MeV level is the T = 3/2 Cl37 ground state analog. The ground state Q-value of the Ca40 (p, ∝) K37 reaction has been measured: -5179 ± 9 keV. This value implies a K37 mass excess of -24804 ± 10 keV. Description of a NMR magnetometer and a sixteen-detector array used in conjunction with a 61-cm double-focusing magnetic spectrometer are included in appendices.
Resumo:
In the first section of this thesis, two-dimensional properties of the human eye movement control system were studied. The vertical - horizontal interaction was investigated by using a two-dimensional target motion consisting of a sinusoid in one of the directions vertical or horizontal, and low-pass filtered Gaussian random motion of variable bandwidth (and hence information content) in the orthogonal direction. It was found that the random motion reduced the efficiency of the sinusoidal tracking. However, the sinusoidal tracking was only slightly dependent on the bandwidth of the random motion. Thus the system should be thought of as consisting of two independent channels with a small amount of mutual cross-talk.
These target motions were then rotated to discover whether or not the system is capable of recognizing the two-component nature of the target motion. That is, the sinusoid was presented along an oblique line (neither vertical nor horizontal) with the random motion orthogonal to it. The system did not simply track the vertical and horizontal components of motion, but rotated its frame of reference so that its two tracking channels coincided with the directions of the two target motion components. This recognition occurred even when the two orthogonal motions were both random, but with different bandwidths.
In the second section, time delays, prediction and power spectra were examined. Time delays were calculated in response to various periodic signals, various bandwidths of narrow-band Gaussian random motions and sinusoids. It was demonstrated that prediction occurred only when the target motion was periodic, and only if the harmonic content was such that the signal was sufficiently narrow-band. It appears as if general periodic motions are split into predictive and non-predictive components.
For unpredictable motions, the relationship between the time delay and the average speed of the retinal image was linear. Based on this I proposed a model explaining the time delays for both random and periodic motions. My experiments did not prove that the system is sampled data, or that it is continuous. However, the model can be interpreted as representative of a sample data system whose sample interval is a function of the target motion.
It was shown that increasing the bandwidth of the low-pass filtered Gaussian random motion resulted in an increase of the eye movement bandwidth. Some properties of the eyeball-muscle dynamics and the extraocular muscle "active state tension" were derived.