2 resultados para non-uniform scale perturbation finite difference scheme

em National Center for Biotechnology Information - NCBI


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work, we used direct measurements with the surface force apparatus to determine the pH-dependent electrostatic charge density of a single binding face of streptavidin. Mean field calculations have been used with considerable success to model electrostatic potential fields near protein surfaces, but these models and their inherent assumptions have not been tested directly at the molecular level. Using the force apparatus and immobilized, oriented monolayers of streptavidin, we measured a pI of 5–5.5 for the biotin-binding face of the protein. This differs from the pI of 6.3 for the soluble protein and confirms that we probed the local electrostatic features of the macromolecule. With finite difference solutions of the linearized Poisson–Boltzmann equation, we then calculated the pH-dependent charge densities adjacent to the same face of the protein. These calculated values agreed quantitatively with those obtained by direct force measurements. Although our study focuses on the pH-dependence of surface electrostatics, this direct approach to probing the electrostatic features of proteins is applicable to investigations of any perturbations that alter the charge distribution of the surfaces of immobilized molecules.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Representational difference analysis (RDA) was applied to isolate chromosomal markers in the rat. Four series of RDA [restriction enzymes, BamHI and HindIII; subtraction of ACI/N (ACI) amplicon from BUF/Nac (BUF) amplicon and vice versa] yielded 131 polymorphic markers; 125 of these markers were mapped to all chromosomes except for chromosome X. This was done by using a mapping panel of 105 ACI x BUF F2 rats. To complement the relative paucity of chromosomal markers in the rat, genetically directed RDA, which allows isolation of polymorphic markers in the specific chromosomal region, was performed. By changing the F2 driver-DNA allele frequency around the region, four markers were isolated from the D1Ncc1 locus. Twenty-five of 27 RDA markers were informative regarding the dot blot analysis of amplicons, hybridizing only with tester amplicons. Dot blot analysis at a high density per unit of area made it possible to process a large number of samples. Quantitative trait loci can now be mapped in the rat genome by processing a large number of samples with RDA markers and then by isolating markers close to the loci of interest by genetically directed RDA.