3 resultados para Pulsed laser range finder

em National Center for Biotechnology Information - NCBI


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Light-induced radical pairs in deuterated and deuterated plus 15N-substituted Synechococcus lividus cyanobacteria have been studied by transient EPR following pulsed laser excitation. Nuclear quantum beats are observed in the transverse electron magnetization at lower temperatures. Model calculations for the time profiles, evaluated at the high-field emissive maximum of the spectrum, indicate assignment of these coherences to nitrogen nuclei in the primary donor. Thorough investigation of the nuclear modulation patterns can provide detailed information on the electronic structure of the primary donor, providing insight into the mechanism of the primary events of plant photosynthesis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

"Snapshot" images of localized Ca2+ influx into patch-clamped chromaffin cells were captured by using a recently developed pulsed-laser imaging system. Transient opening of voltage-sensitive Ca2+ channels gave rise to localized elevations of Ca2+ that had the appearance of either "hotspots" or partial rings found immediately beneath the plasma membrane. When the Ca2+ imaging technique was employed in conjunction with flame-etched carbon-fiber electrodes to spatially map the release sites of catecholamines, it was observed that the sites of Ca2+ entry and catecholamine release were colocalized. These results provide functional support for the idea that secretion occurs from "active zone"-like structures in neuroendocrine cells.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Lasers emitting in the ultraviolet wavelength range of 260-360 nm are almost exclusively used for matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) of macromolecules. Reports about the use of lasers emitting in the infrared first appeared in 1990/1991. In contrast to MALDI in the ultraviolet, a very limited number of reports on IR-MALDI have since been published. Several matrices have been identified for infrared MALDI yielding spectra of a quality comparable to those obtained in the ultraviolet. Water (ice) was recognized early as a potential matrix because of its strong O-H stretching mode near 3 microm. Interest in water as matrix derives primarily from the fact that it is the major constituent of most biological tissues. If functional as matrix, it might allow the in situ analysis of macromolecular constituents in frozen cell sections without extraction or exchanging the water. We present results that show that IR-MALDI of lyophilized proteins, air dried protein solutions, or protein crystals up to a molecular mass of 30 kDa is possible without the addition of any separate matrix. Samples must be frozen to retain a sufficient fraction of the water of hydration in the vacuum. The limited current sensitivity, requiring at least 10 pmol of protein for a successful analysis needs to be further improved.