2 resultados para Multi-resolution Method
em National Center for Biotechnology Information - NCBI
Mapping nucleosome position at single base-pair resolution by using site-directed hydroxyl radicals.
Resumo:
A base-pair resolution method for determining nucleosome position in vitro has been developed to com- plement existing, less accurate methods. Cysteaminyl EDTA was tethered to a recombinant histone octamer via a mutant histone H4 with serine 47 replaced by cysteine. When assembled into nucleosome core particles, the DNA could be cut site specifically by hydroxyl radical-catalyzed chain scission by using the Fenton reaction. Strand cleavage occurs mainly at a single nucleotide close to the dyad axis of the core particle, and assignment of this location via the symmetry of the nucleosome allows base-pair resolution mapping of the histone octamer position on the DNA. The positions of the histone octamer and H3H4 tetramer were mapped on a 146-bp Lytechinus variegatus 5S rRNA sequence and a twofold-symmetric derivative. The weakness of translational determinants of nucleosome positioning relative to the overall affinity of the histone proteins for this DNA is clearly demonstrated. The predominant location of both histone octamer and H3H4 tetramer assembled on the 5S rDNA is off center. Shifting the nucleosome core particle position along DNA within a conserved rotational phase could be induced under physiologically relevant conditions. Since nucleosome shifting has important consequences for chromatin structure and gene regulation, an approach to the thermodynamic characterization of this movement is proposed. This mapping method is potentially adaptable for determining nucleosome position in chromatin in vivo.
Resumo:
We describe a novel high resolution DNA based typing approach for HLA class I alleles, which identifies the recombinational motifs present in exons 2 and 3 of the HLA class I genes. Unique identification patterns for 201 known HLA-A, HLA-B, and HLA-Cw alleles were generated by the use of only 40 probes, which were targeted at these common motifs. The unambiguous identification of the alleles was achieved by the development of a new and powerful allelic separation technique that allows isolation of single alleles after amplification. To validate the method, we have used locus-specific primers to amplify exons 2 and 3 of HLA-A, HLA-B, and HLA-Cw loci from 22 heterozygous and 41 homozygous cell lines. After amplification, the allelic fragments from each locus were separated, blotted, and hybridized with the 40 probes. In all cases, the allelic products could be separated and 81 different class I alleles, 33 HLA-A, 30 HLA-B, and 18 HLA-Cw, were identified according to the predicted probe hybridization patterns.