2 resultados para Hemodialysis Patients

em National Center for Biotechnology Information - NCBI


Relevância:

70.00% 70.00%

Publicador:

Resumo:

beta-2-Microglobulin (beta-2m) is a major constituent of amyloid fibrils in patients with dialysis-related amyloidosis (DRA). Recently, we found that the pigmented and fluorescent adducts formed nonenzymatically between sugar and protein, known as advanced glycation end products (AGEs), were present in beta-2m-containing amyloid fibrils, suggesting the possible involvement of AGE-modified beta-2m in bone and joint destruction in DRA. As an extension of our search for the native structure of AGEs in beta-2m of patients with DRA, the present study focused on pentosidine, a fluorescent cross-linked glycoxidation product. Determination by both HPLC assay and competitive ELISA demonstrated a significant amount of pentosidine in amyloid-fibril beta-2m from long-term hemodialysis patients with DRA, and the acidic isoform of beta-2m in the serum and urine of hemodialysis patients. A further immunohistochemical study revealed the positive immunostaining for pentosidine and immunoreactive AGEs and beta-2m in macrophage-infiltrated amyloid deposits of long-term hemodialysis patients with DRA. These findings implicate a potential link of glycoxidation products in long-lived beta-2m-containing amyloid fibrils to the pathogenesis of DRA.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We have spectroscopically determined breath ammonia levels in seven patients with end-stage renal disease while they were undergoing hemodialysis at the University of California, Los Angeles, dialysis center. We correlated these measurements against simultaneously taken blood samples that were analyzed for blood urea nitrogen (BUN) and creatinine, which are the accepted standards indicating the level of nitrogenous waste loading in a patient's bloodstream. Initial levels of breath ammonia, i.e., at the beginning of dialysis, are between 1,500 ppb and 2,000 ppb (parts per billion). These levels drop very sharply in the first 15–30 min as the dialysis proceeds. We found the reduction in breath ammonia concentration to be relatively slow from this point on to the end of dialysis treatment, at which point the levels tapered off at 150 to 200 ppb. For each breath ammonia measurement, taken at 15–30 min intervals during the dialysis, we also sampled the patient's blood for BUN and creatinine. The breath ammonia data were available in real time, whereas the BUN and creatinine data were available generally 24 h later from the laboratory. We found a good correlation between breath ammonia concentration and BUN and creatinine. For one of the patients, the correlation gave an R2 of 0.95 for breath ammonia and BUN correlation and an R2 of 0.83 for breath ammonia and creatinine correlation. These preliminary data indicate the possibility of using the real-time breath ammonia measurements for determining efficacy and endpoint of hemodialysis.