23 resultados para high resolution image


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report on a procedure for tissue preparation that combines thoroughly controlled physical and chemical treatments: quick-freezing and freeze-drying followed by fixation with OsO4 vapors and embedding by direct resin infiltration. Specimens of frog cutaneous pectoris muscle thus prepared were analyzed for total calcium using electron spectroscopic imaging/electron energy loss spectroscopy (ESI/EELS) approach. The preservation of the ultrastructure was excellent, with positive K/Na ratios revealed in the fibers by x-ray microanalysis. Clear, high-resolution EELS/ESI calcium signals were recorded from the lumen of terminal cisternae of the sarcoplasmic reticulum but not from longitudinal cisternae, as expected from previous studies carried out with different techniques. In many mitochondria, calcium was below detection whereas in others it was appreciable although at variable level. Within the motor nerve terminals, synaptic vesicles as well as some cisternae of the smooth endoplasmic reticulum yielded positive signals at variance with mitochondria, that were most often below detection. Taken as a whole, the present study reveals the potential of our experimental approach to map with high spatial resolution the total calcium within individual intracellular organelles identified by their established ultrastructure, but only where the element is present at high levels.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We describe an integrated approach to large-scale physical mapping using an Alu-PCR hybridization screening strategy in conjunction with direct PCR-based screening to construct a continuous yeast artificial chromosome map covering >20 mb in human chromosome 3, bands p14-p21, composed of 205 loci, connected by 480 yeast artificial chromosomes, with average interlocus distance of approximately equal to 100 kb. We observe an inverse distribution of Alu-PCR and (CA)n markers. These results suggest that the two screening methods may be complementary and demonstrate the utility of Alu-PCR hybridization screening in the closure of high-resolution human physical maps.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The development of a highly reliable physical map with landmark sites spaced an average of 100 kbp apart has been a central goal of the Human Genome Project. We have approached the physical mapping of human chromosome 11 with this goal as a primary target. We have focused on strategies that would utilize yeast artificial chromosome (YAC) technology, thus permitting long-range coverage of hundreds of kilobases of genomic DNA, yet we sought to minimize the ambiguities inherent in the use of this technology, particularly the occurrence of chimeric genomic DNA clones. This was achieved through the development of a chromosome 11-specific YAC library from a human somatic cell hybrid line that has retained chromosome 11 as its sole human component.To maximize the efficiency of YAC contig assembly and extension, we have employed an Alu-PCR-based hybridization screening system. This system eliminates many of the more costly and time-consuming steps associated with sequence tagged site content mapping such as sequencing, primer production, and hierarchical screening, resulting in greater efficiency with increased throughput and reduced cost. Using these approaches, we have achieved YAC coverage for >90% of human chromosome 11, with an average intermarker distance of <100 kbp. Cytogenetic localization has been determined for each contig by fluorescent in situ hybridization and/or sequence tagged site content. The YAC contigs that we have generated should provide a robust framework to move forward to sequence-ready templates for the sequencing efforts of the Human Genome Project as well as more focused positional cloning on chromosome 11.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Kinesin is a molecular motor that transports organelles along microtubules. This enzyme has two identical 7-nm-long motor domains, which it uses to move between consecutive tubulin binding sites spaced 8 nm apart along a microtubular protofilament. The molecular mechanism of this movement, which remains to be elucidated, may be common to all families of motor proteins. In this study, a high-resolution optical-trap microscope was used to measure directly the magnitude of abrupt displacements produced by a single kinesin molecule transporting a microscopic bead. The distribution of magnitudes reveals that kinesin not only undergoes discrete 8-nm movements, in agreement with previous work [Svoboda, K., Schmidt, C. F., Schnapp, B. J. & Block, S.M. (1993) Nature (London) 365, 721-727], but also frequently exhibits smaller movements of about 5 nm. A possible explanation for these unexpected smaller movements is that kinesin's movement from one dimer to the next along a protofilament involves at least two distinct events in the mechanical cycle.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Various types of physical mapping data were assembled by developing a set of computer programs (Integrated Mapping Package) to derive a detailed, annotated map of a 4-Mb region of human chromosome 13 that includes the BRCA2 locus. The final assembly consists of a yeast artificial chromosome (YAC) contig with 42 members spanning the 13q12-13 region and aligned contigs of 399 cosmids established by cross-hybridization between the cosmids, which were selected from a chromosome 13-specific cosmid library using inter-Alu PCR probes from the YACs. The end sequences of 60 cosmids spaced nearly evenly across the map were used to generate sequence-tagged sites (STSs), which were mapped to the YACs by PCR. A contig framework was generated by STS content mapping, and the map was assembled on this scaffold. Additional annotation was provided by 72 expressed sequences and 10 genetic markers that were positioned on the map by hybridization to cosmids.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Amino acid sequencing by recombinant DNA technology, although dramatically useful, is subject to base reading errors, is indirect, and is insensitive to posttranslational processing. Mass spectrometry techniques can provide molecular weight data from even relatively large proteins for such cDNA sequences and can serve as a check of an enzyme's purity and sequence integrity. Multiply-charged ions from electrospray ionization can be dissociated to yield structural information by tandem mass spectrometry, providing a second method for gaining additional confidence in primary sequence confirmation. Here, accurate (+/- 1 Da) molecular weight and molecular ion dissociation information for human muscle and brain creatine kinases has been obtained by electrospray ionization coupled with Fourier-transform mass spectrometry to help distinguish which of several published amino acid sequences for both enzymes are correct. The results herein are consistent with one published sequence for each isozyme, and the heterogeneity indicated by isoelectric focusing due to 1-Da deamidation changes. This approach appears generally useful for detailed sequence verification of recombinant proteins.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The ability to carry out high-resolution genetic mapping at high throughput in the mouse is a critical rate-limiting step in the generation of genetically anchored contigs in physical mapping projects and the mapping of genetic loci for complex traits. To address this need, we have developed an efficient, high-resolution, large-scale genome mapping system. This system is based on the identification of polymorphic DNA sites between mouse strains by using interspersed repetitive sequence (IRS) PCR. Individual cloned IRS PCR products are hybridized to a DNA array of IRS PCR products derived from the DNA of individual mice segregating DNA sequences from the two parent strains. Since gel electrophoresis is not required, large numbers of samples can be genotyped in parallel. By using this approach, we have mapped > 450 polymorphic probes with filters containing the DNA of up to 517 backcross mice, potentially allowing resolution of 0.14 centimorgan. This approach also carries the potential for a high degree of efficiency in the integration of physical and genetic maps, since pooled DNAs representing libraries of yeast artificial chromosomes or other physical representations of the mouse genome can be addressed by hybridization of filter representations of the IRS PCR products of such libraries.