2 resultados para Stent

em Scielo España


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background and aim: This article provides a practical review to undertaking safe endoscopic ampullectomy and highlights some of the common difficulties with this technique as well as offering strategies to deal with these challenges. Methods: We conducted a review of studies regarding endoscopic ampullectomy for ampullary neoplasms with special focus on techniques. Results: Accurate preoperative diagnosis and staging of ampullary tumors is imperative for predicting prognosis and determining the most appropriate therapeutic approach. The optimal technique for endoscopic ampullectomy is dependent on the lesions size. En bloc resection is recommended for lesions confined to the papilla. There is no significant evidence to support the submucosal injection before ampullectomy. There is no consensus regarding the optimal current and power output for endoscopic ampulectomy. The benefits of a thermal adjunctive therapy remain controversial. A prophylactic pancreatic stent reduces the incidence and severity of pancreatitis post-ampullectomy. Conclusions: Endoscopic ampullectomy is a safe and efficacious therapeutic procedure for papillary adenomas in experienced endoscopist and it can avoid the need for surgical intervention.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Postoperative esophageal leaks have a high morbidity and mortality. Self-expanding metal stents (SEMS) have been used as an alternative to re-operation. Aim: Evaluating predictors of success of SEMS in postoperative esophageal leaks. Methods: Retrospective study of patients with postoperative esophageal leaks referred for SEMS placement in a reference center during a period of 3 years. Technical success was defined as closure of the leak in barium swallow at 15 days. Clinical success was considered as endoscopic and/or radiographic confirmation of closure after stent removal. Results: Thirteen patients placed SEMS. Median follow-up was 58 days. Leaks had a median size of 20 mm. Time between surgery and SEMS placement was 20 days. One patient died 2 days after SEMS placement and one had worsening of the fistula after SEMS expansion. Time till stent migration was 9 days. Technical success was achieved in 9 of 11 patients, with clinical success without recurrence in 5 patients. All leaks with less than 20 mm were solved endoscopically. Technical and clinical success was higher when time between surgery and SEMS placement was lower, even though without statistical significance (respectively, p = 0.228 and 0.374). In the 8 patients who died during follow-up, median survival was 59 days. Conclusions: Technical success of SEMS was higher than 80%; however, due to high morbidity and mortality, only 45% of patients had their stent removed. Lower time from diagnosis to SEMS placement and leak size less than 20 mm may be associated with better results.