5 resultados para Fistula
em Scielo España
Resumo:
Objective: This study aims to demonstrate the effectiveness and safety of autologous fibrin gel rich in platelet growth factors for the treatment of complex perianal fistulas. Material and methods: Prospective epidemiological study. Patients with complex perianal fistula or perianal fistula mere alteration of continence are included. identification of both holes and the journey, curettage of it and instillation of Vivostat PRF® in the way it is done to observe excess material by OFE. The variables analyzed were: age, sex, use of prior Seton clinic prevalent type of fistula, postoperative complications, fistula closure and impaired quality of life using the SF-36 test (v2). Results: From January 2011 to May 2013 have involved 23 patients, 12 men and 11 women, with an average age of 49 years and a minimum follow-up of 12 months. Two dropped out. 17 patients had low transsphincteric fistulas, 2 and 2 high transsphincteric intersphincteric with impaired continence. The most common symptom is the discharge. Twelve patients had a loose seton (62%), of which nine cured. Of all the patients we have operated the success rate is 62%. No patient developed incontinence after treatment. Only two reported a worse quality of life after surgery. Conclusion: This study demonstrates that there is a clear benefit to the use of Vivostat PRF® as a treatment for complex perianal fistulas. It is a highly reproducible technique with acceptable results and does not produce impairment of continence.
Resumo:
Background: Postoperative esophageal leaks have a high morbidity and mortality. Self-expanding metal stents (SEMS) have been used as an alternative to re-operation. Aim: Evaluating predictors of success of SEMS in postoperative esophageal leaks. Methods: Retrospective study of patients with postoperative esophageal leaks referred for SEMS placement in a reference center during a period of 3 years. Technical success was defined as closure of the leak in barium swallow at 15 days. Clinical success was considered as endoscopic and/or radiographic confirmation of closure after stent removal. Results: Thirteen patients placed SEMS. Median follow-up was 58 days. Leaks had a median size of 20 mm. Time between surgery and SEMS placement was 20 days. One patient died 2 days after SEMS placement and one had worsening of the fistula after SEMS expansion. Time till stent migration was 9 days. Technical success was achieved in 9 of 11 patients, with clinical success without recurrence in 5 patients. All leaks with less than 20 mm were solved endoscopically. Technical and clinical success was higher when time between surgery and SEMS placement was lower, even though without statistical significance (respectively, p = 0.228 and 0.374). In the 8 patients who died during follow-up, median survival was 59 days. Conclusions: Technical success of SEMS was higher than 80%; however, due to high morbidity and mortality, only 45% of patients had their stent removed. Lower time from diagnosis to SEMS placement and leak size less than 20 mm may be associated with better results.
Resumo:
We present the case of a 69 year old woman with a history of cholecystitis, who consulted for severe abdominal pain, nausea and vomiting. Abdominal CT showed duodenal obstruction caused by a gallstone, cholecystoduodenal fistula and pneumobilia, what is known as Bouveret's syndrome, a rare form of gallstone ileus. Additionally, she presented free duodenal and vesicular perforation to retroperitoneum at the same level of the cholecystoduodenal transit point. The patient underwent a difficult cholecystectomy, enterolithotomy, repair of the duodenal defect, extensive washing and drainage of the retroperitoneum. The postoperative course was uneventful except for a laparotomy infection.