9 resultados para silicone tube

em Universidad Politécnica de Madrid


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Upwardpropagation of a premixed flame in averticaltubefilled with a very leanmixture is simulated numerically using a single irreversible Arrhenius reaction model with infinitely high activation energy. In the absence of heat losses and preferential diffusion effects, a curved flame with stationary shape and velocity close to those of an open bubble ascending in the same tube is found for values of the fuel mass fraction above a certain minimum that increases with the radius of the tube, while the numerical computations cease to converge to a stationary solution below this minimum mass fraction. The vortical flow of the gas behind the flame and in its transport region is described for tubes of different radii. It is argued that this flow may become unstable when the fuel mass fraction is decreased, and that this instability, together with the flame stretch due to the strong curvature of the flame tip in narrow tubes, may be responsible for the minimum fuel mass fraction. Radiation losses and a Lewis number of the fuel slightly above unity decrease the final combustion temperature at the flame tip and increase the minimum fuel mass fraction, while a Lewis number slightly below unity has the opposite effect.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents an analysis of the transport of electric current in a jet of an electrically conducting liquid discharging from a metallic tube into a gas or a vacuum, and subject to an electric field due to a high voltage applied between the tube and a far electrode. The flow, the surface charge and the electric field are computed in the current transfer region of the jet, where conduction current in the liquid becomes surface current due to the convection of electric charge accumulated at its surface. The electric current computed as a function of the flow rate of the liquid injected through the tube increases first as the square root of this flow rate, levels to a nearly constant value when the flow rate is increased and finally sets to a linear increase when the flow rate is further increased. The current increases linearly with the applied voltage at small and moderate values of this variable, and faster than linearly at high voltages. The characteristic length and structure of the current transfer region are determined. Order-of-magnitude estimates for jets which are only weakly stretched by the electric stresses are worked out that qualitatively account for some of the numerical results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The laminar low Mach number flow of a gas in a tube is analyzed for very small and very large values of the inlet-to-wall temperature ratio. When this ratio tends to zero, pressure forces confine the cold gas to a thin core around the axis of the tube. This core is neatly bounded by an ablation front that consumes it at a finite distance from the tube inlet. When the temperature ratio tends to infinity, the temperature of the gas increases smoothly from the wall to the axis of the tube and the shear stress and heat flux are positive at the wall despite the fact that the viscosity and thermal conductivity of the gas scaled with their inlet values tend to zero at the wall

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Integrated Safety Assessment (ISA) methodology, developed by the Spanish Nuclear Safety Council (CSN), has been applied to a thermo-hydraulical analysis of a Westinghouse 3-loop PWR plant by means of the dynamic event trees (DET) for Steam Generator Tube Rupture (SGTR) sequences. The ISA methodology allows obtaining the SGTR Dynamic Event Tree taking into account the operator actuation times. Simulations are performed with SCAIS (Simulation Code system for Integrated Safety Assessment), which includes a dynamic coupling with MAAP thermal hydraulic code. The results show the capability of the ISA methodology and SCAIS platform to obtain the DET of complex sequences.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ponencia invitada sobre asignacion y gestion de losts en el curso de verano de la UPM Research in Decisión Support Systems for future Air Traffic Management

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The stationary upward propagation of a very lean methane/air flame in a long vertical tube open at the bottom and closed at the top is simulated numerically using a single overall chemical reaction to model combustion and assuming an optically thin gas and a transparent or non-reflecting tube wall to approximately account for radiation losses from CO2CO2 and H2OH2O. Buoyancy plays a dominant role in the propagation of these flames and causes a large region of low velocity of the burnt gas relative to the flame to appear below the flame front when the equivalence ratio is decreased. The size of this region scales with the radius of the tube, and its presence enhances the effect of radiation losses, which would be otherwise negligible for a standard flammability tube, given the small concentration of radiating species. Heat conduction is found to be important in the low velocity region and to lead to a conduction flux from the flame to the burnt gas that causes extinction at the flame tip for a value of the equivalence ratio near the flammability limit experimentally measured in the standard tube. The effect of radiation losses decreases with the radius of the tube. Numerical results and order-of-magnitude estimates show that, in the absence of radiation, a very lean flame front fails to propagate only after recirculation of the burnt gas extends to its reaction region and drastically changes its structure. This condition is not realized for the standard flammability tube, but it seems to account for the flammability limit measured in a tube of about half the radius of the standard tube.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The current research aims to analyse theoretically and evaluate a self-manufactured simple design for subsurface drip irrigation (SDI) emitter to avoid root and soil intrusion. It was composed of three concentric cylindrical elements: an elastic silicone membrane; a polyethylene tube with two holes drilled on its wall for water discharge; and a vinyl polychloride protector system to wrap the other elements. The discharge of the emitter depends on the change in the membrane diameter when it is deformed by the water pressure. The study of the operation of this emitter is a new approach that considers mechanical and hydraulic principles. Thus, the estimation on the membrane deformation was based on classical mechanical stress theories in composite cylinders. The hydraulic principles considered the solid deformation due to force based on water pressure and the general Darcy–Weisbach head-loss equation. Twenty emitter units, with the selected design, were handcrafted in a lathe and were used in this study. The measured pressure/discharge relationship for the emitters showed good agreement with that calculated by the theoretical approach. The variation coefficient of the handcrafted emitters was high compared to commercial emitters. Results from field evaluations showed variable values for the relative flow variation, water emission uniformity and relative flow rate coefficients, but no emitter was obstructed. Therefore, the current emitter design could be suitable for SDI following further studies to develop a final prototype.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Article New Forests November 2015, Volume 46, Issue 5, pp 869-883 First online: 17 June 2015 Establishing Quercus ilex under Mediterranean dry conditions: sowing recalcitrant acorns versus planting seedlings at different depths and tube shelter light transmissionsJuan A. OlietAffiliated withDepartamento de Sistemas y Recursos Naturales, E.T.S. Ingenieros de Montes, Universidad Politécnica de Madrid Email author View author's OrcID profile , Alberto Vázquez de CastroAffiliated withDepartamento de Sistemas y Recursos Naturales, E.T.S. Ingenieros de Montes, Universidad Politécnica de Madrid, Jaime PuértolasAffiliated withLancaster Environment Centre, Lancaster University $39.95 / €34.95 / £29.95 * Rent the article at a discount Rent now * Final gross prices may vary according to local VAT. Get Access AbstractSuccess of Mediterranean dry areas restoration with oaks is a challenging goal. Testing eco-techniques that mimic beneficial effects of natural structures and ameliorate stress contributes to positive solutions to overcoming establishment barriers. We ran a factorial experiment in a dry area, testing two levels of solid wall transmission of tube shelters (60 and 80 %) plus a control mesh, and two depths (shallow and 15 cm depth) of placing either planted seedlings or acorns of Quercus ilex. Microclimate of the planting or sowing spots was characterized by measuring photosynthetically active radiation, temperature and relative humidity. Plant response was evaluated in terms of survival, phenology, acorn emergence and photochemical efficiency (measured through chlorophyll fluorescence). We hypothesize that tube shelters and deep planting improve Q. ilex post-planting and sowing performance because of the combined effects of reducing excessive radiation and improving access to moist soil horizons. Results show that temperature and PAR was reduced, and relative humidity increased, in deep spots. Midsummer photochemical efficiency indicates highest level of stress for oaks in 80 % light transmission shelter. Optimum acorn emergence in spring was registered within solid wall tree shelters, and maximum summer survival of germinants and of planted seedlings occurred when acorns or seedlings were placed at 15 cm depth irrespectively of light transmission of shelter. Survival of germinants was similar to that of planted seedlings. The importance of techniques to keep high levels of viability after sowing recalcitrant seeds in the field is emphasized in the study

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The In Vessel Viewing System (IVVS) will be one of the essential machine diagnostic systems at ITER to provide information about the status of in-vessel and plasma facing components and to evaluate the dust inside the Vacuum Vessel. The current design consists of six scanning probes and their deployment systems, which are placed in dedicated ports at the divertor level. These units are located in resident guiding tubes 10 m long, which allow the IVVS probes to go from their storage location to the scanning position by means of a simple straight translation. Moreover, each resident tube is supported inside the corresponding Vacuum Vessel and Cryostat port extensions, which are part of the primary confinement barrier. As the Vacuum Vessel and the Cryostat will move with respect to each other during operation (especially during baking) and during incidents and accidents (disruptions, vertical displacement events, seismic events), the structural integrity of the resident tube and the surrounding vacuum boundaries would be compromised if the required flexibility and supports are not appropriately assured. This paper focuses on the integration of the present design of the IVVS into the Vacuum Vessel and Cryostat environment. It presents the adopted strategy to withstand all the main interfacing loads without damaging the confinement barriers and the corresponding analysis supporting it.