26 resultados para ramp heat flux

em Universidad Politécnica de Madrid


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The need to refine models for best-estimate calculations, based on good-quality experimental data, has been expressed in many recent meetings in the field of nuclear applications. The modeling needs arising in this respect should not be limited to the currently available macroscopic methods but should be extended to next-generation analysis techniques that focus on more microscopic processes. One of the most valuable databases identified for the thermalhydraulics modeling was developed by the Nuclear Power Engineering Corporation (NUPEC), Japan. From 1987 to 1995, NUPEC performed steady-state and transient critical power and departure from nucleate boiling (DNB) test series based on the equivalent full-size mock-ups. Considering the reliability not only of the measured data, but also other relevant parameters such as the system pressure, inlet sub-cooling and rod surface temperature, these test series supplied the first substantial database for the development of truly mechanistic and consistent models for boiling transition and critical heat flux. Over the last few years the Pennsylvania State University (PSU) under the sponsorship of the U.S. Nuclear Regulatory Commission (NRC) has prepared, organized, conducted and summarized the OECD/NRC Full-size Fine-mesh Bundle Tests (BFBT) Benchmark. The international benchmark activities have been conducted in cooperation with the Nuclear Energy Agency/Organization for Economic Co-operation and Development (NEA/OECD) and Japan Nuclear Energy Safety (JNES) organization, Japan. Consequently, the JNES has made available the Boiling Water Reactor (BWR) NUPEC database for the purposes of the benchmark. Based on the success of the OECD/NRC BFBT benchmark the JNES has decided to release also the data based on the NUPEC Pressurized Water Reactor (PWR) subchannel and bundle tests for another follow-up international benchmark entitled OECD/NRC PWR Subchannel and Bundle Tests (PSBT) benchmark. This paper presents an application of the joint Penn State University/Technical University of Madrid (UPM) version of the well-known subchannel code COBRA-TF, namely CTF, to the critical power and departure from nucleate boiling (DNB) exercises of the OECD/NRC BFBT and PSBT benchmarks

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A known nonlocal model of electron heat flux, applying for (scale length/thermal ion-electron mean-free path) of order Z)1/2(e*/T)312, ionization number Z, large, and e*~ 6.5 T (the energy of electrons carrying most of the flux), is reconsidered. The large e*/T ratio simplifies the complete formalism. A simple flux formula, exact for both smooth and steep profiles, is given. Thermoelectric effects and other models are discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A single, nonlocal expression for the electron heat flux, which closely reproduces known results at high and low ion charge number 2, and “exact” results for the local limit at all 2, is derived by solving the kinetic equation in a narrow, tail-energy range. The solution involves asymptotic expansions of Bessel functions of large argument, and (Z-dependent)order above or below it, corresponding to the possible parabolic or hyperbolic character of the kinetic equation; velocity space diffusion in self-scattering is treated similarly to isotropic thermalization of tail energies in large Z analyses. The scale length H characterizing nonlocal effects varies with Z, suggesting an equal dependence of any ad hoc flux limiter. The model is valid for all H above the mean-free path for thermal electrons.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A previous hydrodynamic model of the expansion of a laser-produced plasma, using classical (Spitzer) heat flux, is reconsidered with a nonlocal heat flux model. The nonlocal law is shown to be valid beyond the range of validity of the classical law, breaking down ultimately, however, in agreement with recent predictions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Electron thermal conduction in a not quite collisional unmagnetlzed plasma is analysed. The failure of classical results for temperature scale-length up to 100 times larger than thermal mean-free-path for electron scattering, and large ion-charge number Z , is discussed. Recent results from a nonlocal model of conduction at large Z are reviewed. Closed form expressions for Braginskii's coefficients a ,/3 , y for Z =0(1) are derived. An extension of the nonlocal model for Z =0(1) is discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Over the last few years, the Pennsylvania State University (PSU) under the sponsorship of the US Nuclear Regulatory Commission (NRC) has prepared, organized, conducted, and summarized two international benchmarks based on the NUPEC data—the OECD/NRC Full-Size Fine-Mesh Bundle Test (BFBT) Benchmark and the OECD/NRC PWR Sub-Channel and Bundle Test (PSBT) Benchmark. The benchmarks’ activities have been conducted in cooperation with the Nuclear Energy Agency/Organization for Economic Co-operation and Development (NEA/OECD) and the Japan Nuclear Energy Safety (JNES) Organization. This paper presents an application of the joint Penn State University/Technical University of Madrid (UPM) version of the well-known sub-channel code COBRA-TF (Coolant Boiling in Rod Array-Two Fluid), namely, CTF, to the steady state critical power and departure from nucleate boiling (DNB) exercises of the OECD/NRC BFBT and PSBT benchmarks. The goal is two-fold: firstly, to assess these models and to examine their strengths and weaknesses; and secondly, to identify the areas for improvement.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The quasisteady structure of the corona of a laser-irradiated pellet is completely determined for arbitrary Z, (ion charge number} and re/ra (ratio of critical and ablation radii), and for heat-flux saturation factor/above approximately 0.04. The ion-to-electron temperature ratio at rc grows sensibly with Z,; all other quantities depend weakly and nonmonotonically on Z,. For rc /ra close to unity, and all Z, of interest (Z, < 47}, the flow is subsonic at rc. For a given laser power W, flux saturation may decrease (low/) or increase (high/) the ablation pressure Pa relative to the value obtained when saturation is not considered; in some cases a decrease in/with W fixed increases Pa. For intermediate^ ~0.1), Pa cc (W/r* )2/3 p\n\pc = critical density), independently of rc/ra; for/~0.6, Pa «s larger by a factor of about [rc/raf13. For rjra > 1.2 roughly, the mass ablation rate is C{Z,) [{m/kZ.f^Kr^Pl) l,\ independent of pc and/, and barely dependent on Z,(m, is ion mass; k, Boltzmann's constant; K, conductivity coefficient; and C, a tabulated function).

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A recently obtained nonlocal expression for the electron heat flux valid for arbitrary ionization numbers Z is used to study the structure of a plane shock wave in a fully ionized plasma. Nonlocal effects are only important in the foot of the electronic preheating region, where the electron temperature gradient is the steepest. The results are quantified as a function of a characteristic Knudsen number of that region. This work also generalizes to arbitrary values of Z previous results on plasma shock wave structure.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The laminar low Mach number flow of a gas in a tube is analyzed for very small and very large values of the inlet-to-wall temperature ratio. When this ratio tends to zero, pressure forces confine the cold gas to a thin core around the axis of the tube. This core is neatly bounded by an ablation front that consumes it at a finite distance from the tube inlet. When the temperature ratio tends to infinity, the temperature of the gas increases smoothly from the wall to the axis of the tube and the shear stress and heat flux are positive at the wall despite the fact that the viscosity and thermal conductivity of the gas scaled with their inlet values tend to zero at the wall.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The laminar low Mach number flow of a gas in a tube is analyzed for very small and very large values of the inlet-to-wall temperature ratio. When this ratio tends to zero, pressure forces confine the cold gas to a thin core around the axis of the tube. This core is neatly bounded by an ablation front that consumes it at a finite distance from the tube inlet. When the temperature ratio tends to infinity, the temperature of the gas increases smoothly from the wall to the axis of the tube and the shear stress and heat flux are positive at the wall despite the fact that the viscosity and thermal conductivity of the gas scaled with their inlet values tend to zero at the wall

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The heterogeneous incoming heat flux in solar parabolic trough absorber tubes generates huge temperature difference in each pipe section. Helical internal fins can reduce this effect, homogenising the temperature profile and reducing thermal stress with the drawback of increasing pressure drop. Another effect is the decreasing of the outer surface temperature and thermal losses, improving the thermal efficiency of the collector. The application of internal finned tubes for the design of parabolic trough collectors is analysed with computational fluid dynamics tools. Our numerical approach has been qualified with the computational estimation of reported experimental data regarding phenomena involved in finned tube applications and solar irradiation of parabolic trough collector. The application of finned tubes to the design of parabolic trough collectors must take into account issues as the pressure losses, thermal losses and thermo-mechanical stress, and thermal fatigue. Our analysis shows an improvement potential in parabolic trough solar plants efficiency by the application of internal finned tubes.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The evapotranspiration (ET c) of a table grape vineyard (Vitis vinifera, cv. Red Globe) trained to a gable trellis under netting and black plastic mulching was determined under semiarid conditions in the central Ebro River Valley during 2007 and 2008. The netting was made of high-density polyethylene (pores of 12 mm2) and was placed just above the ground canopy about 2.2 m above soil surface. Black plastic mulching was used to minimize soil evaporation. The surface renewal method was used to obtain values of sensible heat flux (H) from high-frequency temperature readings. Later, latent heat flux (LE) values were obtained by solving the energy balance equation. For the May–October period, seasonal ET c was about 843 mm in 2007 and 787 mm in 2008. The experimental weekly crop coefficients (K cexp) fluctuated between 0.64 and 1.2. These values represent crop coefficients adjusted to take into account the reduction in ET c caused by the netting and the black plastic mulching. Average K cexp values during mid- and end-season stages were 0.79 and 0.98, respectively. End-season K cexp was higher due to combination of factors related to the precipitation and low ET o conditions that are typical in this region during fall. Estimated crop coefficients using the Allen et al. (1998) approach adjusting for the effects of the netting and black plastic mulching (K cFAO) showed a good agreement with the experimental K cexp values.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The evapotranspiration (ETc) of sprinkler-irrigated rice was determined for the semiarid conditions of NE Spain during 2001, 2002 and 2003. The surface renewal method, after calibration against the eddy covariance method, was used to obtain values of sensible heat flux (H) from high-frequency temperature readings. Latent heat flux values were obtained by solving the energy balance equation. Finally, lysimeter measurements were used to validate the evapotranspiration values obtained with the surface renewal method. Seasonal rice evapotranspiration was about 750–800 mm. Average daily ETc for mid-season (from 90 to 130 days after sowing) was 5.1, 4.5 and 6.1 mm day−1 for 2001, 2002 and 2003, respectively. The experimental weekly crop coefficients fluctuated in the range of 0.83–1.20 for 2001, 0.81–1.03 for 2002 and 0.84–1.15 for 2003. The total growing season was about 150–160 days. In average, the crop coefficients for the initial (Kcini), mid-season (Kcmid) and late-season stages (Kcend) were 0.92, 1.06 and 1.03, respectively, the length of these stages being about 55, 45 and 25 days, respectively.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The one-dimensional motion generated in a cold, infinite, uniform plasma of density na by the absorption, in a certain plane, of a linear pulse of energy per unit time and area = 4>0t/r, 0< t< r, is considered, the analysis allows for thermal conduction and viscosity of ions and electrons, their energy exchange, and an electron heat flux limiter The resulting motion is self-similar and governed by a single nondimensional parameter a«(n0 2T/0)2/3 Detailed asymptotic results are obtained for both a < l and a > l , the general behavior of the solution for arbitrary a is discussed The analysis can be extended to the case of a plasma initially occupying a half-space, and throws light on how to optimize the hydrodynamics of laser fusion plasmas Known approximate results corresponding to motion of a plasma submitted to constant irradiation (<()) are recovered in the present work under appropriate limiting processes