38 resultados para performance analysis

em Universidad Politécnica de Madrid


Relevância:

100.00% 100.00%

Publicador:

Resumo:

An important step to assess water availability is to have monthly time series representative of the current situation. In this context, a simple methodology is presented for application in large-scale studies in regions where a properly calibrated hydrologic model is not available, using the output variables simulated by regional climate models (RCMs) of the European project PRUDENCE under current climate conditions (period 1961–1990). The methodology compares different interpolation methods and alternatives to generate annual times series that minimise the bias with respect to observed values. The objective is to identify the best alternative to obtain bias-corrected, monthly runoff time series from the output of RCM simulations. This study uses information from 338 basins in Spain that cover the entire mainland territory and whose observed values of natural runoff have been estimated by the distributed hydrological model SIMPA. Four interpolation methods for downscaling runoff to the basin scale from 10 RCMs are compared with emphasis on the ability of each method to reproduce the observed behaviour of this variable. The alternatives consider the use of the direct runoff of the RCMs and the mean annual runoff calculated using five functional forms of the aridity index, defined as the ratio between potential evapotranspiration and precipitation. In addition, the comparison with respect to the global runoff reference of the UNH/GRDC dataset is evaluated, as a contrast of the “best estimator” of current runoff on a large scale. Results show that the bias is minimised using the direct original interpolation method and the best alternative for bias correction of the monthly direct runoff time series of RCMs is the UNH/GRDC dataset, although the formula proposed by Schreiber (1904) also gives good results

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The main objective of this paper is to review the state of the art of residential PV systems in France and Belgium. This is done analyzing the operational data of 10650 PV systems (9657 located in France and 993 in Belgium). Three main questions are posed. How much energy do they produce? What level of performance is associated to their production? Which are the key parameters that most influence their quality? During the year 2010, the PV systems in France have produced a mean annual energy of 1163 kWh/kWp in France and 852 kWh/kWp in Belgium. As a whole, the orientation of PV generators causes energy productions to be some 7% inferior to optimally oriented PV systems. The mean Performance Ratio is 76% in France and 78% in Belgium, and the mean Performance Index is 85% in both countries. On average, the real power of the PV modules falls 4.9% below its corresponding nominal power announced on the manufacturer?s datasheet. A brief analysis by PV modules technology has lead to relevant observations about two technologies in particular. On the one hand, the PV systems equipped with Heterojunction with Intrinsic. Thin layer (HIT) modules show performances higher than average. On the other hand, the systems equipped with Copper Indium (di)Selenide (CIS) modules show a real power that is 16 % lower than their nominal value.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the course of discussing different target types for their suitability in the European Spallation Source (ESS) one main focus was on neutronics' performance. Diverse concepts have been assessed baselining some preliminary engineering and geometrical details and including some optimization. With the restrictions and resulting uncertainty imposed by the lack of detailed designs optimizations at the time of compiling this paper, the conclusion drawn is basically that there is a little difference in the neutronic yield of the investigated targets. Other criteria like safety, environmental compatibility, reliability and cost will thus dominate the choice of an ESS target.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An n(++)-GaAs/p(++)-AlGaAs tunnel junction with a peak current density of 10 100Acm(-2) is developed. This device is a tunnel junction for multijunction solar cells, grown lattice-matched on standard GaAs or Ge substrates, with the highest peak current density ever reported. The voltage drop for a current density equivalent to the operation of the multijunction solar cell up to 10 000 suns is below 5 mV. Trap-assisted tunnelling is proposed to be behind this performance, which cannot be justified by simple band-to-band tunnelling. The metal-organic vapour-phase epitaxy growth conditions, which are in the limits of the transport-limited regime, and the heavy tellurium doping levels are the proposed origins of the defects enabling trap-assisted tunnelling. The hypothesis of trap-assisted tunnelling is supported by the observed annealing behaviour of the tunnel junctions, which cannot be explained in terms of dopant diffusion or passivation. For the integration of these tunnel junctions into a triple-junction solar cell, AlGaAs barrier layers are introduced to suppress the formation of parasitic junctions, but this is found to significantly degrade the performance of the tunnel junctions. However, the annealed tunnel junctions with barrier layers still exhibit a peak current density higher than 2500Acm(-2) and a voltage drop at 10 000 suns of around 20 mV, which are excellent properties for tunnel junctions and mean they can serve as low-loss interconnections in multijunction solar cells working at ultra-high concentrations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The degradation observed on a 7-kWp Si-x photovoltaic array after 17 years of exposure on the roof of the Solar Energy Institute of the Polytechnic University of Madrid is presented. The mean peak power degradation has been 9% over this time, or an equivalent to 0.53% per year, whereas peak power standard deviation has remained constant. The main visual defects are backsheet delamination at the polyester/polyvinyl fluoride outer interface and cracks in the terminal boxes and at the joint between the frame and the laminate. Insulation resistance complies well with the requirements of the International Electrotechnical Commission 61215 tests.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

As the world becomes more urbanised, public transport in cities must seek to provide viable alternatives to individual car transport. At an urban level, interchanges in public transport networks provide easy transfers between and within different transport modes and facilitate seamless travel. This study proposes a methodological framework with which to identify the factors that travellers view as key elements of an urban transport interchange. An attitudinal survey was undertaken in order to collect information about users? needs and perceptions in the Moncloa interchange in Madrid, Spain. The results obtained from an Importance-Performance Analysis (IPA) show that aspects related to the signposting of different facilities and transport services, the internal design of the interchange and the surrounding area, and safety and security are the greatest strengths of the interchange.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Performance of football teams varies constantly due to the dynamic nature of this sport, whilst the typical performance and its spread can be represented by profiles combining different performance-related variables based on data from multiple matches. The current study aims to use a profiling technique to evaluate and compare match performance of football teams in the UEFA Champions League incorporating three situational variables (i.e. strength of team and opponent, match outcome and match location). Match statistics of 72 teams, 496 games across four seasons (2008-09 to 2012-13) of this competition were analysed. Sixteen performance-related events were included: shots, shots on target, shots from open play, shots from set piece, shots from counter attack, passes, pass accuracy (%), crosses, through balls, corners, dribbles, possession, aerial success (%), fouls, tackles, and yellow cards. Teams were classified into three levels of strength by a k-cluster analysis. Profiles of overall performance and profiles incorporating three situational variables for teams of all three levels of strength were set up by presenting the mean, standard deviation, median, lower and upper quartiles of the counts of each event to represent their typical performances and spreads. Means were compared by using one-way ANOVA and independent sample t test (for match location, home and away differences), and were plotted into the same radar charts after unifying all the event counts by standardised score. Established profiles can present straightforwardly typical performances of football teams of different levels playing in different situations, which could provide detailed references for coaches and analysts to evaluate performances of upcoming opposition and of their own.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The aim of the study was to evaluate the match work-rate of Chinese field hockey players by analyzing the distance covered at different intensities pooled by specific positions during different periods of matches. Thirty-eight players from twenty-four male field hockey matches at the 11th Chinese National Games were filmed and analyzed.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The aim of the study was to evaluate the match work-rate of Chinese field hockey players by analyzing the distance covered at different intensities pooled by specific positions during different periods of matches. Thirty-eight players from twenty-four male field hockey matches at the 11th Chinese National Games were filmed and analyzed.mas

Relevância:

70.00% 70.00%

Publicador:

Resumo:

El MC en baloncesto es aquel fenómeno relacionado con el juego que presenta unas características particulares determinadas por la idiosincrasia de un equipo y puede afectar a los protagonistas y por ende al devenir del juego. En la presente Tesis se ha estudiado la incidencia del MC en Liga A.C.B. de baloncesto y para su desarrollo en profundidad se ha planteado dos investigaciones una cuantitativa y otra cualitativa cuya metodología se detalla a continuación: La investigación cuantitativa se ha basado en la técnica de estudio del “Performance analysis”, para ello se han estudiado cuatro temporadas de la Liga A.C.B. (del 2007/08 al 2010/11), tal y como refleja en la bibliografía consultada se han tomado como momentos críticos del juego a los últimos cinco minutos de partidos donde la diferencia de puntos fue de seis puntos y todos los Tiempos Extras disputados, de tal manera que se han estudiado 197 momentos críticos. La contextualización del estudio se ha hecho en función de la variables situacionales “game location” (local o visitante), “team quality” (mejores o peores clasificados) y “competition” (fases de LR y Playoff). Para la interpretación de los resultados se han realizado los siguientes análisis descriptivos: 1) Análisis Discriminante, 2) Regresión Lineal Múltiple; y 3) Análisis del Modelo Lineal General Multivariante. La investigación cualitativa se ha basado en la técnica de investigación de la entrevista semiestructurada. Se entrevistaron a 12 entrenadores que militaban en la Liga A.C.B. durante la temporada 2011/12, cuyo objetivo ha sido conocer el punto de vista que tiene el entrenador sobre el concepto del MC y que de esta forma pudiera dar un enfoque más práctico basado en su conocimiento y experiencia acerca de cómo actuar ante el MC en el baloncesto. Los resultados de ambas investigaciones coinciden en señalar la importancia del MC sobre el resultado final del juego. De igual forma, el concepto en sí entraña una gran complejidad por lo que se considera fundamental la visión científica de la observación del juego y la percepción subjetiva que presenta el entrenador ante el fenómeno, para la cual los aspectos psicológicos de sus protagonistas (jugadores y entrenadores) son determinantes. ABSTRACT The Critical Moment (CM) in basketball is a related phenomenon with the game that has particular features determined by the idiosyncrasies of a team and can affect the players and therefore the future of the game. In this Thesis we have studied the impact of CM in the A.C.B. League and from a profound development two investigations have been raised, quantitative and qualitative whose methodology is as follows: The quantitative research is based on the technique of study "Performance analysis", for this we have studied four seasons in the A.C.B. League (2007/08 to 2010/11), and as reflected in the literature the Critical Moments of the games were taken from the last five minutes of games where the point spread was six points and all overtimes disputed, such that 197 critical moments have been studied. The contextualization of the study has been based on the situational variables "game location" (home or away), "team quality" (better or lower classified) and "competition" (LR and Playoff phases). For the interpretation of the results the following descriptive analyzes were performed: 1) Discriminant Analysis, 2) Multiple Linear Regression Analysis; and 3) Analysis of Multivariate General Linear Model. Qualitative research is based on the technique of investigation of a semi-structured interview. 12 coaches who belonged to the A.C.B. League were interviewed in seasons 2011/12, which aimed to determine the point of view that the coach has on the CM concept and thus could give a more practical approach based on their knowledge and experience about how to deal with the CM in basketball. The results of both studies agree on the importance of the CM on the final outcome of the game. Similarly, the concept itself is highly complex so the scientific view of the observation of the game is considered essential as well as the subjective perception the coach presents before the phenomenon, for which the psychological aspects of their characters (players and coaches) are crucial.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

El propósito de esta tesis es presentar una metodología para realizar análisis de la dinámica en pequeña señal y el comportamiento de sistemas de alimentación distribuidos de corriente continua (CC), formados por módulos comerciales. Para ello se hace uso de un método sencillo que indica los márgenes de estabilidad menos conservadores posibles mediante un solo número. Este índice es calculado en cada una de las interfaces que componen el sistema y puede usarse para obtener un índice global que indica la estabilidad del sistema global. De esta manera se posibilita la comparación de sistemas de alimentación distribuidos en términos de robustez. La interconexión de convertidores CC-CC entre ellos y con los filtros EMI necesarios puede originar interacciones no deseadas que dan lugar a la degradación del comportamiento de los convertidores, haciendo el sistema más propenso a inestabilidades. Esta diferencia en el comportamiento se debe a interacciones entre las impedancias de los diversos elementos del sistema. En la mayoría de los casos, los sistemas de alimentación distribuida están formados por módulos comerciales cuya estructura interna es desconocida. Por ello los análisis presentados en esta tesis se basan en medidas de la respuesta en frecuencia del convertidor que pueden realizarse desde los terminales de entrada y salida del mismo. Utilizando las medidas de las impedancias de entrada y salida de los elementos del sistema, se puede construir una función de sensibilidad que proporciona los márgenes de estabilidad de las diferentes interfaces. En esta tesis se utiliza el concepto del valor máximo de la función de sensibilidad (MPC por sus siglas en inglés) para indicar los márgenes de estabilidad como un único número. Una vez que la estabilidad de todas las interfaces del sistema se han evaluado individualmente, los índices obtenidos pueden combinarse para obtener un único número con el que comparar la estabilidad de diferentes sistemas. Igualmente se han analizado las posibles interacciones en la entrada y la salida de los convertidores CC-CC, obteniéndose expresiones analíticas con las que describir en detalle los acoplamientos generados en el sistema. Los estudios analíticos realizados se han validado experimentalmente a lo largo de la tesis. El análisis presentado en esta tesis se culmina con la obtención de un índice que condensa los márgenes de estabilidad menos conservativos. También se demuestra que la robustez del sistema está asegurada si las impedancias utilizadas en la función de sensibilidad se obtienen justamente en la entrada o la salida del subsistema que está siendo analizado. Por otra parte, la tesis presenta un conjunto de parámetros internos asimilados a impedancias, junto con sus expresiones analíticas, que permiten una explicación detallada de las interacciones en el sistema. Dichas expresiones analíticas pueden obtenerse bien mediante las funciones de transferencia analíticas si se conoce la estructura interna, o utilizando medidas en frecuencia o identificación de las mismas a través de la respuesta temporal del convertidor. De acuerdo a las metodologías presentadas en esta tesis se puede predecir la estabilidad y el comportamiento de sistemas compuestos básicamente por convertidores CC-CC y filtros, cuya estructura interna es desconocida. La predicción se basa en un índice que condensa la información de los márgenes de estabilidad y que permite la obtención de un indicador de la estabilidad global de todo el sistema, permitiendo la comparación de la estabilidad de diferentes arquitecturas de sistemas de alimentación distribuidos. ABSTRACT The purpose of this thesis is to present dynamic small-signal stability and performance analysis methodology for dc-distributed systems consisting of commercial power modules. Furthermore, the objective is to introduce simple method to state the least conservative margins for robust stability as a single number. In addition, an index characterizing the overall system stability is obtained, based on which different dc-distributed systems can be compared in terms of robustness. The interconnected systems are prone to impedance-based interactions which might lead to transient-performance degradation or even instability. These systems typically are constructed using commercial converters with unknown internal structure. Therefore, the analysis presented throughout this thesis is based on frequency responses measurable from the input and output terminals. The stability margins are stated utilizing a concept of maximum peak criteria, derived from the behavior of impedance-based sensitivity function that provides a single number to state robust stability. Using this concept, the stability information at every system interface is combined to a meaningful number to state the average robustness of the system. In addition, theoretical formulas are extracted to assess source and load side interactions in order to describe detailed couplings within the system. The presented theoretical analysis methodologies are experimentally validated throughout the thesis. In this thesis, according to the presented analysis, the least conservative stability margins are provided as a single number guaranteeing robustness. It is also shown that within the interconnected system the robust stability is ensured only if the impedance-based minor-loop gain is determined at the very input or output of each subsystem. Moreover, a complete set of impedance-type internal parameters as well as the formulas according to which the interaction sensitivity can be fully explained and analyzed, is provided. The given formulation can be utilized equally either based on measured frequency responses, time-domain identified internal parameters or extracted analytic transfer functions. Based on the analysis methodologies presented in this thesis, the stability and performance of interconnected systems consisting of converters with unknown internal structure, can be predicted. Moreover, the provided concept to assess the least conservative stability margins enables to obtain an index to state the overall robust stability of distributed power architecture and thus to compare different systems in terms of stability.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Multiuser multiple-input multiple-output (MIMO) downlink (DL) transmission schemes experience both multiuser interference as well as inter-antenna interference. The singular value decomposition provides an appropriate mean to process channel information and allows us to take the individual user’s channel characteristics into account rather than treating all users channels jointly as in zero-forcing (ZF) multiuser transmission techniques. However, uncorrelated MIMO channels has attracted a lot of attention and reached a state of maturity. By contrast, the performance analysis in the presence of antenna fading correlation, which decreases the channel capacity, requires substantial further research. The joint optimization of the number of activated MIMO layers and the number of bits per symbol along with the appropriate allocation of the transmit power shows that not necessarily all user-specific MIMO layers has to be activated in order to minimize the overall BER under the constraint of a given fixed data throughput.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The integration of powerful partial evaluation methods into practical compilers for logic programs is still far from reality. This is related both to 1) efficiency issues and to 2) the complications of dealing with practical programs. Regarding efnciency, the most successful unfolding rules used nowadays are based on structural orders applied over (covering) ancestors, i.e., a subsequence of the atoms selected during a derivation. Unfortunately, maintaining the structure of the ancestor relation during unfolding introduces significant overhead. We propose an efficient, practical local unfolding rule based on the notion of covering ancestors which can be used in combination with any structural order and allows a stack-based implementation without losing any opportunities for specialization. Regarding the second issue, we propose assertion-based techniques which allow our approach to deal with real programs that include (Prolog) built-ins and external predicates in a very extensible manner. Finally, we report on our implementation of these techniques in a practical partial evaluator, embedded in a state of the art compiler which uses global analysis extensively (the Ciao compiler and, specifically, its preprocessor CiaoPP). The performance analysis of the resulting system shows that our techniques, in addition to dealing with practical programs, are also significantly more efficient in time and somewhat more efficient in memory than traditional tree-based implementations.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this paper, the authors provide a methodology to design nonparametric permutation tests and, in particular, nonparametric rank tests for applications in detection. In the first part of the paper, the authors develop the optimization theory of both permutation and rank tests in the Neyman?Pearson sense; in the second part of the paper, they carry out a comparative performance analysis of the permutation and rank tests (detectors) against the parametric ones in radar applications. First, a brief review of some contributions on nonparametric tests is realized. Then, the optimum permutation and rank tests are derived. Finally, a performance analysis is realized by Monte-Carlo simulations for the corresponding detectors, and the results are shown in curves of detection probability versus signal-to-noise ratio

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Las fuentes de alimentación de modo conmutado (SMPS en sus siglas en inglés) se utilizan ampliamente en una gran variedad de aplicaciones. La tarea más difícil para los diseñadores de SMPS consiste en lograr simultáneamente la operación del convertidor con alto rendimiento y alta densidad de energía. El tamaño y el peso de un convertidor de potencia está dominado por los componentes pasivos, ya que estos elementos son normalmente más grandes y más pesados que otros elementos en el circuito. Para una potencia de salida dada, la cantidad de energía almacenada en el convertidor que ha de ser entregada a la carga en cada ciclo de conmutación, es inversamente proporcional a la frecuencia de conmutación del convertidor. Por lo tanto, el aumento de la frecuencia de conmutación se considera un medio para lograr soluciones más compactas con los niveles de densidad de potencia más altos. La importancia de investigar en el rango de alta frecuencia de conmutación radica en todos los beneficios que se pueden lograr: además de la reducción en el tamaño de los componentes pasivos, el aumento de la frecuencia de conmutación puede mejorar significativamente prestaciones dinámicas de convertidores de potencia. Almacenamiento de energía pequeña y el período de conmutación corto conducen a una respuesta transitoria del convertidor más rápida en presencia de las variaciones de la tensión de entrada o de la carga. Las limitaciones más importantes del incremento de la frecuencia de conmutación se relacionan con mayores pérdidas del núcleo magnético convencional, así como las pérdidas de los devanados debido a los efectos pelicular y proximidad. También, un problema potencial es el aumento de los efectos de los elementos parásitos de los componentes magnéticos - inductancia de dispersión y la capacidad entre los devanados - que causan pérdidas adicionales debido a las corrientes no deseadas. Otro factor limitante supone el incremento de las pérdidas de conmutación y el aumento de la influencia de los elementos parásitos (pistas de circuitos impresos, interconexiones y empaquetado) en el comportamiento del circuito. El uso de topologías resonantes puede abordar estos problemas mediante el uso de las técnicas de conmutaciones suaves para reducir las pérdidas de conmutación incorporando los parásitos en los elementos del circuito. Sin embargo, las mejoras de rendimiento se reducen significativamente debido a las corrientes circulantes cuando el convertidor opera fuera de las condiciones de funcionamiento nominales. A medida que la tensión de entrada o la carga cambian las corrientes circulantes incrementan en comparación con aquellos en condiciones de funcionamiento nominales. Se pueden obtener muchos beneficios potenciales de la operación de convertidores resonantes a más alta frecuencia si se emplean en aplicaciones con condiciones de tensión de entrada favorables como las que se encuentran en las arquitecturas de potencia distribuidas. La regulación de la carga y en particular la regulación de la tensión de entrada reducen tanto la densidad de potencia del convertidor como el rendimiento. Debido a la relativamente constante tensión de bus que se encuentra en arquitecturas de potencia distribuidas los convertidores resonantes son adecuados para el uso en convertidores de tipo bus (transformadores cc/cc de estado sólido). En el mercado ya están disponibles productos comerciales de transformadores cc/cc de dos puertos que tienen muy alta densidad de potencia y alto rendimiento se basan en convertidor resonante serie que opera justo en la frecuencia de resonancia y en el orden de los megahercios. Sin embargo, las mejoras futuras en el rendimiento de las arquitecturas de potencia se esperan que vengan del uso de dos o más buses de distribución de baja tensión en vez de una sola. Teniendo eso en cuenta, el objetivo principal de esta tesis es aplicar el concepto del convertidor resonante serie que funciona en su punto óptimo en un nuevo transformador cc/cc bidireccional de puertos múltiples para atender las necesidades futuras de las arquitecturas de potencia. El nuevo transformador cc/cc bidireccional de puertos múltiples se basa en la topología de convertidor resonante serie y reduce a sólo uno el número de componentes magnéticos. Conmutaciones suaves de los interruptores hacen que sea posible la operación en las altas frecuencias de conmutación para alcanzar altas densidades de potencia. Los problemas posibles con respecto a inductancias parásitas se eliminan, ya que se absorben en los Resumen elementos del circuito. El convertidor se caracteriza con una muy buena regulación de la carga propia y cruzada debido a sus pequeñas impedancias de salida intrínsecas. El transformador cc/cc de puertos múltiples opera a una frecuencia de conmutación fija y sin regulación de la tensión de entrada. En esta tesis se analiza de forma teórica y en profundidad el funcionamiento y el diseño de la topología y del transformador, modelándolos en detalle para poder optimizar su diseño. Los resultados experimentales obtenidos se corresponden con gran exactitud a aquellos proporcionados por los modelos. El efecto de los elementos parásitos son críticos y afectan a diferentes aspectos del convertidor, regulación de la tensión de salida, pérdidas de conducción, regulación cruzada, etc. También se obtienen los criterios de diseño para seleccionar los valores de los condensadores de resonancia para lograr diferentes objetivos de diseño, tales como pérdidas de conducción mínimas, la eliminación de la regulación cruzada o conmutación en apagado con corriente cero en plena carga de todos los puentes secundarios. Las conmutaciones en encendido con tensión cero en todos los interruptores se consiguen ajustando el entrehierro para obtener una inductancia magnetizante finita en el transformador. Se propone, además, un cambio en los señales de disparo para conseguir que la operación con conmutaciones en apagado con corriente cero de todos los puentes secundarios sea independiente de la variación de la carga y de las tolerancias de los condensadores resonantes. La viabilidad de la topología propuesta se verifica a través una extensa tarea de simulación y el trabajo experimental. La optimización del diseño del transformador de alta frecuencia también se aborda en este trabajo, ya que es el componente más voluminoso en el convertidor. El impacto de de la duración del tiempo muerto y el tamaño del entrehierro en el rendimiento del convertidor se analizan en un ejemplo de diseño de transformador cc/cc de tres puertos y cientos de vatios de potencia. En la parte final de esta investigación se considera la implementación y el análisis de las prestaciones de un transformador cc/cc de cuatro puertos para una aplicación de muy baja tensión y de decenas de vatios de potencia, y sin requisitos de aislamiento. Abstract Recently, switch mode power supplies (SMPS) have been used in a great variety of applications. The most challenging issue for designers of SMPS is to achieve simultaneously high efficiency operation at high power density. The size and weight of a power converter is dominated by the passive components since these elements are normally larger and heavier than other elements in the circuit. If the output power is constant, the stored amount of energy in the converter which is to be delivered to the load in each switching cycle is inversely proportional to the converter’s switching frequency. Therefore, increasing the switching frequency is considered a mean to achieve more compact solutions at higher power density levels. The importance of investigation in high switching frequency range comes from all the benefits that can be achieved. Besides the reduction in size of passive components, increasing switching frequency can significantly improve dynamic performances of power converters. Small energy storage and short switching period lead to faster transient response of the converter against the input voltage and load variations. The most important limitations for pushing up the switching frequency are related to increased conventional magnetic core loss as well as the winding loss due to the skin and proximity effect. A potential problem is also increased magnetic parasitics – leakage inductance and capacitance between the windings – that cause additional loss due to unwanted currents. Higher switching loss and the increased influence of printed circuit boards, interconnections and packaging on circuit behavior is another limiting factor. Resonant power conversion can address these problems by using soft switching techniques to reduce switching loss incorporating the parasitics into the circuit elements. However the performance gains are significantly reduced due to the circulating currents when the converter operates out of the nominal operating conditions. As the input voltage or the load change the circulating currents become higher comparing to those ones at nominal operating conditions. Multiple Input-Output Many potential gains from operating resonant converters at higher switching frequency can be obtained if they are employed in applications with favorable input voltage conditions such as those found in distributed power architectures. Load and particularly input voltage regulation reduce a converter’s power density and efficiency. Due to a relatively constant bus voltage in distributed power architectures the resonant converters are suitable for bus voltage conversion (dc/dc or solid state transformation). Unregulated two port dc/dc transformer products achieving very high power density and efficiency figures are based on series resonant converter operating just at the resonant frequency and operating in the megahertz range are already available in the market. However, further efficiency improvements of power architectures are expected to come from using two or more separate low voltage distribution buses instead of a single one. The principal objective of this dissertation is to implement the concept of the series resonant converter operating at its optimum point into a novel bidirectional multiple port dc/dc transformer to address the future needs of power architectures. The new multiple port dc/dc transformer is based on a series resonant converter topology and reduces to only one the number of magnetic components. Soft switching commutations make possible high switching frequencies to be adopted and high power densities to be achieved. Possible problems regarding stray inductances are eliminated since they are absorbed into the circuit elements. The converter features very good inherent load and cross regulation due to the small output impedances. The proposed multiple port dc/dc transformer operates at fixed switching frequency without line regulation. Extensive theoretical analysis of the topology and modeling in details are provided in order to compare with the experimental results. The relationships that show how the output voltage regulation and conduction losses are affected by the circuit parasitics are derived. The methods to select the resonant capacitor values to achieve different design goals such as minimum conduction losses, elimination of cross regulation or ZCS operation at full load of all the secondary side bridges are discussed. ZVS turn-on of all the switches is achieved by relying on the finite magnetizing inductance of the Abstract transformer. A change of the driving pattern is proposed to achieve ZCS operation of all the secondary side bridges independent on load variations or resonant capacitor tolerances. The feasibility of the proposed topology is verified through extensive simulation and experimental work. The optimization of the high frequency transformer design is also addressed in this work since it is the most bulky component in the converter. The impact of dead time interval and the gap size on the overall converter efficiency is analyzed on the design example of the three port dc/dc transformer of several hundreds of watts of the output power for high voltage applications. The final part of this research considers the implementation and performance analysis of the four port dc/dc transformer in a low voltage application of tens of watts of the output power and without isolation requirements.