22 resultados para near null magnetic field
em Universidad Politécnica de Madrid
Resumo:
An eiectrodynamic Tether is a long thin conductive string deployed from a spacecraft. A part of the ED tether near one end, which is rendered positive by the Electromotive force (EMF)along the tether, collects electrons from the ambient plasma. In the frame of reference moving with theter, ions flow toward the tether, get deflected near the tether by its high positive potential and create a wake. Due to the asymmetry of plasma distribution and the weak but significant Geomagnetic field, the conventional probe theory becomes almost inapplicable. Computational work for the prediction of current collection is thus necessiated.. In this paper, we analyze effects of magnetic field on velocity distribution funtion at a point that is far from the tether, and discuss a new way to treat electrons at computational boundary. Three cases with different magnetic field are simulated and compiled so as to provide a part of the pre-flight prediction of the space experiment by NASA ProSEDS, which is planned September 2002.
Resumo:
An asymptotic analysis of the Langmuir-probe problem in a quiescent, fully ionized plasma in a strong magnetic field is performed, for electron cyclotron radius and Debye length much smaller than probe radius, and this not larger than either ion cyclotron radius or mean free path. It is found that the electric potential, which is not confined to a sheath, controls the diffusion far from the probe; inside the magnetic tube bounded by the probe cross section the potential overshoots to a large value before decaying to its value in the body of the plasma. The electron current is independent of the shape of the body along the field and increases with ion temperature; due to the overshoot in the potential, (1) the current at negative voltages does not vary exponentially, (2) its magnitude is strongly reduced by the field, and (3) the usual sharp knee at space potential, disappears. In the regions of the C-V diagram studied the ion current is negligible or unaffected by the field. Some numerical results are presented.The theory, which fails beyond certain positive voltage, fields useful results for weak fields, too.
Resumo:
A kinetic approach is used to develop a theory of electrostatic probes in a fully ionized plasma in the presence of a magnetic field. A consistent asymptotic expansion is obtained assuming that the electron Larmor radius is small compared to the radius of the probe. The order of magnitude of neglected terms is given. It is found that the electric potential within the tube of force defined by the cross section of the probe decays non-mono tonic ally from the probe; this bump disappears at a certain probe voltage and the theory is valid up to this voltage. The transition region, which extends beyond plasma potential, is not exponential. The possible saturation of the electron current is discussed. Restricted numerical results are given; they seem to be useful for weaker magnetic fields down to the zero-field limit. Extensions of the theory a r e considered.
Resumo:
In hybrid and electric vehicles, passengers sit very close to an electric system of significant power, which means that they may be subjected to high electromagnetic fields. The hazards of long-term exposure to these fields must be taken into account when designing electric vehicles and their components. Among all the electric devices present in the power train, the electronic converter is the most difficult to analyze, given that it works with different frequencies. In this paper, a methodology to evaluate the magnetic field created by a power electronics converter is proposed. After a brief overview of the recommendations of electromagnetic fields exposure, the magnetic field produced by an inverter is analyzed using finite element techniques. The results obtained are compared to laboratory measurements, taken from a real inverter, in order to validate the model. Finally, results are used to draw some conclusions regarding vehicle design criteria and magnetic shielding efficiency.
Resumo:
Engineering of devices and systems such as magnets, fault current limiters or cables, based on High Temperature Superconducting wires requires a deep characterization of the possible degradation of their properties by handling at room temperature as well as during the service life thus establishing the limits for building up functional devices and systems. In the present work we report our study regarding the mechanical behavior of spliced joints between commercial HTS coated conductors based on YBCO at room temperature and service temperature, 77 K. Tensile tests under axial stress and the evolution of the critical current and the electric resistance of the joints have been measured. The complete strain contour for the tape and the joint has been obtained by using Digital Image Correlation. Also, tensile tests under external magnetic field have been performed and the effect of the applied field on the critical current and the electric resistance of the joints has been studied. Finally, a preliminary numerical study by means of Finite Element Method (FEM) of the mechanical behavior of the joints between commercial HTS is presented.
Resumo:
Engineering of devices and systems such as magnets, fault current limiters or cables, based on High Temperature Superconducting wires requires a deep characterization of the possible degradation of their properties by handling at room temperature as well as during the service life thus establishing the limits for building up functional devices and systems. In the present work we report our study regarding the mechanical behavior of spliced joints between commercial HTS coated conductors based on YBCO at room temperature and service temperature, 77 K. Tensile tests under axial stress and the evolution of the critical current and the electric resistance of the joints have been measured. The complete strain contour for the tape and the joints has been obtained by using Digital Image Correlation. Also, tensile tests under external magnetic field have been performed and the effect of the applied field on the critical current and the electric resistance of the joints has been studied. Additionally, fatigue tests under constant cyclic stress and loading-unloading ramps have been carried out in order to evaluate the electromechanical behavior of the joints and the effect of maximum applied stress on the critical current. Finally, a preliminary numerical study by means of the Finite Element Method (FEM) of the electromechanical behavior of the joints between commercial HTS is presented.
Resumo:
En esta tesis se analiza el sistema de tracción de un vehículo eléctrico de batería desde el punto de vista de la eficiencia energética y de la exposición a campos magnéticos por parte de los pasajeros (radiación electromagnética). Este estudio incluye tanto el sistema de almacenamiento de energía como la máquina eléctrica, junto con la electrónica de potencia y los sistemas de control asociados a ambos. Los análisis y los resultados presentados en este texto están basados en modelos matemáticos, simulaciones por ordenador y ensayos experimentales a escala de laboratorio. La investigación llevada a cabo durante esta tesis tuvo siempre un marcado enfoque industrial, a pesar de estar desarrollada en un entorno de considerable carácter universitario. Las líneas de investigación acometidas tuvieron como destinatario final al diseñador y al fabricante del vehículo, a pesar de lo cual algunos de los resultados obtenidos son preliminares y/o excesivamente académicos para resultar de interés industrial. En el ámbito de la eficiencia energética, esta tesis estudia sistemas híbridos de almacenamiento de energía basados en una combinación de baterías de litio y supercondensadores. Este tipo de sistemas son analizados desde el punto de vista de la eficiencia mediante modelos matemáticos y simulaciones, cuantificando el impacto de ésta en otros parámetros tales como el envejecimiento de las baterías. Respecto a la máquina eléctrica, el estudio se ha centrado en máquinas síncronas de imanes permanentes. El análisis de la eficiencia considera tanto el diseño de la máquina como la estrategia de control, dejando parcialmente de lado el inversor y la técnica de modulación (que son incluidos en el estudio como fuentes adicionales de pérdidas, pero no como potenciales fuentes de optimización de la eficiencia). En este sentido, tanto la topología del inversor (trifásico, basado en IGBTs) como la técnica de modulación (control de corriente en banda de histéresis) se establecen desde el principio. El segundo aspecto estudiado en esta tesis es la exposición a campos magnéticos por parte de los pasajeros. Este tema se enfoca desde un punto de vista predictivo, y no desde un punto de vista de diagnóstico, puesto que se ha desarrollado una metodología para estimar el campo magnético generado por los dispositivos de potencia de un vehículo eléctrico. Esta metodología ha sido validada mediante ensayos de laboratorio. Otros aspectos importantes de esta contribución, además de la metodología en sí misma, son las consecuencias que se derivan de ella (por ejemplo, recomendaciones de diseño) y la comprensión del problema proporcionada por esta. Las principales contribuciones de esta tesis se listan a continuación: una recopilación de modelos de pérdidas correspondientes a la mayoría de dispositivos de potencia presentes en un vehículo eléctrico de batería, una metodología para analizar el funcionamiento de un sistema híbrido de almacenamiento de energía para aplicaciones de tracción, una explicación de cómo ponderar energéticamente los puntos de operación par-velocidad de un vehículo eléctrico (de utilidad para evaluar el rendimiento de una máquina eléctrica, por ejemplo), una propuesta de incluir un convertidor DC-DC en el sistema de tracción para minimizar las pérdidas globales del accionamiento (a pesar de las nuevas pérdidas introducidas por el propio DC-DC), una breve comparación entre dos tipos distintos de algoritmos de minimización de pérdidas para máquinas síncronas de imanes permanentes, una metodología predictiva para estimar la exposición a campos magnéticos por parte de los pasajeros de un vehículo eléctrico (debida a los equipos de potencia), y finalmente algunas conclusiones y recomendaciones de diseño respecto a dicha exposición a campos magnéticos. ABSTRACT This dissertation analyzes the powertrain of a battery electric vehicle, focusing on energy efficiency and passenger exposure to electromagnetic fields (electromagnetic radiation). This study comprises the energy storage system as well as the electric machine, along with their associated power electronics and control systems. The analysis and conclusions presented in this dissertation are based on mathematical models, computer simulations and laboratory scale tests. The research performed during this thesis was intended to be of industrial nature, despite being developed in a university. In this sense, the work described in this document was carried out thinking of both the designer and the manufacturer of the vehicle. However, some of the results obtained lack industrial readiness, and therefore they remain utterly academic. Regarding energy efficiency, hybrid energy storage systems consisting in lithium batteries, supercapacitors and up to two DC-DC power converters are considered. These kind of systems are analyzed by means of mathematical models and simulations from the energy efficiency point of view, quantifying its impact on other relevant aspects such as battery aging. Concerning the electric machine, permanent magnet synchronous machines are studied in this work. The energy efficiency analysis comprises the machine design and the control strategy, while the inverter and its modulation technique are taken into account but only as sources of further power losses, and not as potential sources for further efficiency optimization. In this sense, both the inverter topology (3-phase IGBT-based inverter) and the switching technique (hysteresis current control) are fixed from the beginning. The second aspect studied in this work is passenger exposure to magnetic fields. This topic is approached from the prediction point of view, rather than from the diagnosis point of view. In other words, a methodology to estimate the magnetic field generated by the power devices of an electric vehicle is proposed and analyzed in this dissertation. This methodology has been validated by laboratory tests. The most important aspects of this contribution, apart from the methodology itself, are the consequences (for instance, design guidelines) and the understanding of the magnetic radiation issue provided by it. The main contributions of this dissertation are listed next: a compilation of loss models for most of the power devices found in a battery electric vehicle powertrain, a simulation-based methodology to analyze hybrid energy storage performance in traction applications, an explanation of how to assign energy-based weights to different operating points in traction drives (useful when assessing electrical machine performance, for instance), a proposal to include one DC-DC converter in electric powertrains to minimize overall power losses in the system (despite the new losses added by the DC-DC), a brief comparison between two kinds of loss-minimization algorithms for permanent magnet synchronous machines in terms of adaptability and energy efficiency, a predictive methodology to estimate passenger magnetic field exposure due to power devices in an electric vehicle, and finally some useful conclusions and design guidelines concerning magnetic field exposure.
Resumo:
Transcranial static magnetic field stimulation (tSMS) in humans reduces cortical excitability. Objective: The objective of this study was to determine if prolonged tSMS (2 h) could be delivered safely in humans. Safety limits for this technique have not been described. Methods: tSMS was applied for 2 h with a cylindric magnet on the occiput of 17 healthy subjects. We assessed tSMS-related safety aspects at tissue level by measuring levels of neuron-specific enolase (NSE,a marker of neuronal damage) and S100 (a marker of glial reactivity and damage). We also included an evaluation of cognitive side effects by using a battery of visuomotor and cognitive tests. Results: tSMS did not induce any significant increase in NSE or S100. No cognitive alteration was detected. Conclusions: Our data indicate that the application of tSMS is safe in healthy human subjects, at least within these parameters
Resumo:
Intraoral devices for bite-force sensing have several applications in odontology and maxillofacial surgery, as bite-force measurements provide additional information to help understand the characteristics of bruxism disorders and can also be of help for the evaluation of post-surgical evolution and for comparison of alternative treatments. A new system for measuring human bite forces is proposed in this work. This system has future applications for the monitoring of bruxism events and as a complement for its conventional diagnosis. Bruxism is a pathology consisting of grinding or tight clenching of the upper and lower teeth, which leads to several problems such as lesions to the teeth, headaches, orofacial pain and important disorders of the temporomandibular joint. The prototype uses a magnetic field communication scheme similar to low-frequency radio frequency identification (RFID) technology (NFC). The reader generates a low-frequency magnetic field that is used as the information carrier and powers the sensor. The system is notable because it uses an intra-mouth passive sensor and an external interrogator, which remotely records and processes information regarding a patient?s dental activity. This permits a quantitative assessment of bite-force, without requiring intra-mouth batteries, and can provide supplementary information to polysomnographic recordings, current most adequate early diagnostic method, so as to initiate corrective actions before irreversible dental wear appears. In addition to describing the system?s operational principles and the manufacture of personalized prototypes, this report will also demonstrate the feasibility of the system and results from the first in vitro and in vivo trials.
Resumo:
A quasisteady model for the plasma ablated from a thick foil by a laser pulse, at low $lln $ and R /A i within a low, narrow range, is given (4, is absorbed intensity, /zL wavelength, R focalspot radius). An approximate analytical solution is given for the two-dimensional plasma dynamics. At large magnetic Reynolds number Rm, the morphology of the magnetic field shows features in agreement with recent results for high intensities. Current lines are open: electric current flows toward the spot near its axis, then turns and flows away. The efficiency of converting light energy into electric energy peaks at Rm- 1, both the validity of the model. and accuracy of the solution are discussed, The neighborhood of the spot boundary is analyzed in detail by extending classical Prandtl-Meyer results.
Resumo:
It was recently suggested that the magnetic field created by the current of a bare tether strongly reduces its own electron-collection capability when a magnetic separatrix disconnecting ambient magnetized plasma from tether extends beyond its electric sheath. It is here shown that current reduction by the self-field depends on the ratio meterizing bias and current profiles along the tether (Lt tether length, characteristic length gauging ohmic effects) and on a new dimensionless number Ks involving ambient and tether parameters. Current reduction is weaker the lower Ks and L*/ Lt, which depend critically on the type of cross section: Ks varies as R5/3, h2/3R, and h2/3 1/4 width for wires, round tethers conductive only in a thin layer, and thin tapes, respectively; L* varies as R2/3 for wires and as h2/3 for tapes and round tethers conductive in a layer (R radius, h thickness). Self-field effects are fully negligible for the last two types of cross sections whatever the mode of operation. In practical efficient tether systems having L*/Lt low, maximum current reduction in case of wires is again negligible for power generation; for deorbiting, reduction is <1% for a 10 km tether and 15% for a 20 km tether. In the reboost mode there are no effects for Ks below some threshold; moderate effects may occur in practical but heavy reboost-wire systems that need no dedicated solar power.
Resumo:
A theory is developed of an electrostatic probe in a fully-ionized plasma in the presence of a strong magnetic field. The ratio of electron Larmor radius to probe transverse dimension is assumed to be small. Poisson's equation, together with kinetic equations for ions and electrons are considered. An asymptotic perturbation method of multiple scales is used by considering the characteristic lengths appearing in the problem. The leading behavior of the solution is found. The results obtained appear to apply to weaker fields also, agreeing with the solutions known in the limit of no magnetic field. The range of potentials for wich results are presented is limited. The basic effects produced by the field are a depletion of the plasma near the probe and a non-monotonic potential surrounding the probe. The ion saturation current is not changed but changes appear in both the floating potential Vf and the slope of the current-voltage diagram at Vf. The transition region extends beyond the space potential Vs,at wich point the current is largely reduced. The diagram does not have an exponential form in this region as commonly assumed. There exists saturation in electron collection. The extent to which the plasma is disturbed is determined. A cylindrical probe has no solution because of a logarithmic singularity at infinity. Extensions of the theory are considered.
Resumo:
It has been recently suggested that the magnetic field created by the current in a bare tether could sensibly reduce its electron collection capability in the magnetised ionosphere, a region of closed magnetic surfaces disconnecting the cylinder from infinity. In this paper, the ohmic voltage drop along the tether is taken into account in considering self-field effects. Separate analyses are carried out for the thrust and power generation and drag modes of operation, which are affected in different ways. In the power generation and drag modes, bias decreases as current increases along the tether, starting at the anodic, positively-biased end (upper end in the usual, eastward-flying spacecraft); in the thrust mode of operation, bias increases as current increases along the tether, starting at the lower end. When the ohmic voltage drop is considered, self-field effects are shown to be weak, in all cases, for tape tethers, and for circular cross-section tethers just conductive in a thin outer layer. Self-field effects might become important, in the drag case only, for tethers with fully conductive cross sections that are unrealistically heavy.
Resumo:
El uso de las partículas magnéticas ha venido a más durante los últimos 10 años. Lo anterior ha estado condicionado por factores como la amplia investigación en materiales a nivel atómico, los retos propuestos por las diferentes áreas de investigación donde los niveles nanométricos cobran importancia, la inherente innovación tecnológica que pueden aportar a la industria dichas escalas y finalmente, el impacto socioeconómico que pueden tener estos avances tecnológicos. Sin embargo, la traslación a la industria de los avances tecnológicos se ha visto limitada por la falta de estrategias, ya que el 88% del conocimiento se queda en Universidades y Centros de Investigación y el resto, 12%, pasa a la industria o es obtenido en ella. En este trabajo de investigación se ha tratado de completar el círculo de idea, conceptualización, generación de conocimiento, prototipo, prueba in vitro y prueba in vivo; todo ello para dejar el menor espacio posible entre Investigación e Industria. Se ha fabricado un recinto que permite la observación del comportamiento de las partículas magnéticas cuando están inmersas en un medio con viscosidad controlada y con una fuente magnética estática. De la observación experimental se han encontrado fenómenos magnéticos como la aglomeración y la autoorganización, que han sido aprovechados, no solo para ofrecer una solución alternativa a la corrección del desprendimiento de retina, sino también para promover las mejoras de métodos de separación y/o filtrado celular, ayuda en correcciones ortopédicas o en el diagnóstico y tratamiento de enfermedades degenerativas. Particularizando en la corrección del desprendimiento de retina, se ha desarrollado y patentado un Dispositivo Ocular cuya función es la de tapón del agujero retiniano, ayudando en la cicatrización de la retina. Dicho dispositivo ha sido evaluado en conejos albinos neozelandeses obteniéndose un éxito en la reaplicación de la retina del 80% y resultando su toxicidad en condición difusa tras evaluación anatomopatológica. Así mismo, el ferrofluido diseñado y fabricado se ha localizado en la zona de interacción magnética siempre y su disposición ha sido en el mayor de los casos en forma de placa pero también se han formado anillos; lo anterior no ha afectado en ningún sentido el éxito en la reaplicación de la retina. Por otro lado, no se han encontrado indicios de siderosis en la zona de interacción magnética, sus alrededores o el resto del globo ocular; ni las células han presentado apoptosis inducida por los materiales introducidos en el ojo. Sin embargo, se ha encontrado una fuerte necrosis inducida por la presión ejercida sobre la retina por el dispositivo ocular, evidenciando la necesidad de un mejor control de dicha presión. Tras la caracterización de los copos y la presión que éstos ejercen, se ha podido identificar que el dispositivo ocular se puede sintonizar para inducir una presión entre 0.5 y 2.5 mmHg; por tanto se puede vislumbrar que es posible minimizar la muerte celular causada en las células retinianas. Finalmente, tras la experimentación con conejos se ha observado que el dispositivo ocular resuelve los problemas inducidos por las siliconas o los gases e inclusive aporta ventajas competitivas de alto valor añadido como: no requerir de posiciones incómodas en el post-operatorio, no modifica las propiedades ópticas del ojo ya que no es necesario dejar silicona o gases en el interior del ojo, se pueden sellar múltiples agujeros retinianos, corrección de desprendimiento de retina inferior sin complicaciones asociadas, etc.; en definitiva mejora la calidad de vida domiciliaria del paciente además de solventar los problemas inducidos por las soluciones actuales. The using of magnetic particles has become more important during last 10 years. This event has been conditioned by several factors like a wide researching on materials at atomic level, the challenges proposed by different research areas where nanometric levels became important, the inherent technological innovation to the industry and finally, the socioeconomic impact of these kinds of technologies. However, the nanotechnological advances have not been well addressed to the industry since 88% of the acknowledge keeps on Universities and Research Centers, and the remaining 12% goes through the industry or is obtained in it. In this research work, we have tried to complete the entire process about idea, concept, acknowledge generation, prototyping and in vitro and in vivo testing; all to leave as little space as possible between Research and Industry. We have built an experimental hall which allows us the observation of magnetic particles' behavior when are immersing in a controlled viscous medium and under a static magnetic field. The experimental observation has been useful to identify and use two magnetic phenomena: agglomeration and self-organization; no only for retinal detachment, but also to improve cellular separation and/or filtered methods, orthopedic solutions or the diagnostic and treatment of degenerative diseases. Particularizing on retinal detachment, we have developed and patented an Ocular Device which its function is acting like a tampon of the retinal hole for helping with the scarring retina. The device has been evaluated in animals and the results show that we can achieve a success of 80% before rabbit’s death and non cell apoptosis, only necrosis, over the retina attached by the ocular device after anatomopathological evaluation. Also we have identified a diffuse toxicity after anatomopathological evaluation, so more experimenting must be proposed. Otherwise, the ferrofluid has been localized where the magnetic interaction area is located and its deposition has been in most cases plaque shape like but rings have also been observed; this has not affected in any way the successful reattachment of the retina. On the other hand, we have not found any evidence of siderosis in the magnetic interaction zone, near of or some other place of the ocular globe; and we did not find any apoptosis induced by the materials inserted within the eye. However full necrosis, exactly on the magnetic interaction zone, has been found and induced by the pressure exerted over the retina by the ocular device, evidencing the needing of its better control. After flakes’ characterization and its pressure exerted, we identified that the ocular device can be tuned in order to induce a pressure between 0.5 and 2.5 mmHg; therefore we can perceive that death caused to the retinal cells can be minimized. Finally, the experimentation has shown that the ocular device solves all problems induced by silicone or gases an even contributes with some other competitive advantages of high added value like: no uncomfortable postoperative positions, it does not modify any optical property of the eye because there is no needing of leaving silicone or gases inside the eye, many holes can be sealed, the inferior retinal detachment can be solve without any complications, etc.; definitively the ocular device improves patients’ quality of life.
Resumo:
The Bioinstrumentation Laboratory belongs to the Centre for Biomedical Technology (CTB) of the Technical University of Madrid and its main objective is to provide the scientific community with devices and techniques for the characterization of micro and nanostructures and consequently finding their best biomedical applications. Hyperthermia (greek word for “overheating”) is defined as the phenomenon that occurs when a body is exposed to an energy generating source that can produce a rise in temperature (42-45ºC) for a given time [1]. Specifically, the aim of the hyperthermia methods used in The Bioinstrumentation Laboratory is the development of thermal therapies, some of these using different kinds of nanoparticles, to kill cancer cells and reduce the damage on healthy tissues. The optical hyperthermia is based on noble metal nanoparticles and laser irradiation. This kind of nanoparticles has an immense potential associated to the development of therapies for cancer on account of their Surface Plasmon Resonance (SPR) enhanced light scattering and absorption. In a short period of time, the absorbed light is converted into localized heat, so we can take advantage of these characteristics to heat up tumor cells in order to obtain the cellular death [2]. In this case, the laboratory has an optical hyperthermia device based on a continuous wave laser used to kill glioblastoma cell lines (1321N1) in the presence of gold nanorods (Figure 1a). The wavelength of the laser light is 808 nm because the penetration of the light in the tissue is deeper in the Near Infrared Region. The first optical hyperthermia results show that the laser irradiation produces cellular death in the experimental samples of glioblastoma cell lines using gold nanorods but is not able to decrease the cellular viability of cancer cells in samples without the suitable nanorods (Figure 1b) [3]. The generation of magnetic hyperthermia is performed through changes of the magnetic induction in magnetic nanoparticles (MNPs) that are embedded in viscous medium. The Figure 2 shows a schematic design of the AC induction hyperthermia device in magnetic fluids. The equipment has been manufactured at The Bioinstrumentation Laboratory. The first block implies two steps: the signal selection with frequency manipulation option from 9 KHz to 2MHz, and a linear output up to 1500W. The second block is where magnetic field is generated ( 5mm, 10 turns). Finally, the third block is a software control where the user can establish initial parameters, and also shows the temperature response of MNPs due to the magnetic field applied [4-8]. The Bioinstrumentation Laboratory in collaboration with the Mexican company MRI-DT have recently implemented a new research line on Nuclear Magnetic Resonance Hyperthermia, which is sustained on the patent US 7,423,429B2 owned by this company. This investigation is based on the use of clinical MRI equipment not only for diagnosis but for therapy [9]. This idea consists of two main facts: Magnetic Resonance Imaging can cause focal heating [10], and the differentiation in resonant frequency between healthy and cancer cells [11]. To produce only heating in cancer cells when the whole body is irradiated, it is necessary to determine the specific resonant frequency of the target, using the information contained in the spectra of the area of interest. Then, special RF pulse sequence is applied to produce fast excitation and relaxation mechanism that generates temperature increase of the tumor, causing cellular death or metabolism malfunction that stops cellular division