Resumo:

The main objective of this research is to promote passive thermal design techniques in the construction of wineries. Natural ventilation in underground cellars is analyzed, focusing on the entrance tunnel, the ventilation chimney and the cave. A monitoring system was designed in order to detect changes in the indoor conditions and outdoor air infiltration. Monitoring process was carried out during one year. Results show the influence of outside temperature, ventilation chimney and access tunnel on the conditions inside the underground cellar. During hot periods, natural ventilation has a negligible influence on the indoor ambience, despite the permanently open vents in the door and chimney. The tunnel and ventilation chimney work as a temperature regulator, dampening outside fluctuations. Forced ventilation is necessary when a high air exchange ratio is needed. During cold periods, there is greater instability as a result of increased natural ventilation. The temperature differences along the tunnel are reduced, reflecting a homogenization and mixing of the air. The ventilation flow is sufficient to modify the temperature and relative humidity of the cave. Forced ventilation is not necessary in this period. During the intermediate periods --autumn and spring-- occurs different behaviors based on time of day.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Esta tesis se enmarca dentro de una línea de investigación iniciada en el 2004 focalizada en el estudio de soluciones constructivas energéticamente eficientes para la crianza del vino. El objetivo principal es promover el ahorro energético y la sostenibilidad en el diseño de la sala de crianza de las bodegas. Para ello, se profundiza en el estudio de las bodegas subterráneas, ejemplo de eco-construcción, ya que por lo general proporcionan condiciones adecuadas para la crianza sin gasto energético en climatización. En concreto, se abordan aspectos clave para la caracterización y comprensión del funcionamiento de estas construcciones, que en muchas ocasiones condicionan el éxito o el fracaso de las mismas. Así, se analiza el complejo comportamiento de la ventilación natural a lo largo del año, determinando los factores que la condicionan, desvelando el papel que desempeña tanto el túnel de acceso como las chimeneas de ventilación en su funcionamiento. Además, se desarrollan y validan modelos de simulación mediante CFD, que permiten evaluar y predecir con detalle el comportamiento termofluidodinámico de las construcciones subterráneas. Por otra parte, se cuantifica la uniformidad y estabilidad de la sala de crianza a lo largo del año, información que permite fijar recomendaciones y pautas concretas de diseño de los planes de monitorización. Finalmente, se determinan las diferencias de comportamiento higrotérmico existentes entre un amplio abanico de bodegas subterráneas para vino tinto, bodegas representativas de otras soluciones constructivas alternativas de vino tinto, así como bodegas para cavas y vinos generosos, enmarcando el comportamiento de estas bodegas en un contexto global. Además, se desarrollan metodologías adaptadas a las características particulares de estas construcciones, en concreto un sistema de monitorización basado en termografía infrarroja para llevar a cabo inspecciones puntuales para el control ambiental de grandes naves de crianza. Es de esperar que los estudios técnicos y las herramientas desarrolladas ayuden a mejorar el diseño de nuevas bodegas, y a la mejora de las condiciones higrotérmicas de las ya existentes, colaborando a que España siga situada en la vanguardia de la producción de vino de calidad. ABSTRACT This thesis is part of the research started in 2004 and focusing on the study of the energy efficiency in wine aging constructive solutions. The main objective is to promote energy conservation and sustainability in the design of wine aging rooms. To do so, this study focuses on the analysis of the underground cellars, example of eco-construction, since they usually provide adequate conditions for wine aging without using air-conditioning systems. In particular, key aspects for characterizing and understanding these constructions, which often determine the success or failure of them. Thus, the complex behavior of natural ventilation throughout the year is discussed, determining the influencing factors and revealing the role of both the access tunnel and the ventilation chimney. In addition, numerical models are developed and validated using CFD simulation, allowing an in-depth assessment and prediction of the thermofluidynamic behavior in underground constructions. Moreover, uniformity and stability of the aging room throughout the year is quantified, allowing for precise information useful to set recommendations and design guidelines for defining monitoring plans. Finally, hygrothermal behavior differences between a wide range of underground cellars for red wine, red wine wineries with alternative construction solutions and wineries for generous wines and cava wines, In addition, new methodologies adapted towards the particular characteristics of these constructions, a monitoring system based on infrared thermography to perform periodic inspections for environmental controls of the aging rooms, are developed. It is expected that the technical studies and tools developed here will help to improve the design of new wineries, and also the hygrothermal conditions of the existing ones, headed for keeping Spain in the forefront of the countries producing high quality wine.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The analysis of the wind flow around buildings has a great interest from the point of view of the wind energy assessment, pollutant dispersion control, natural ventilation and pedestrians wind comfort and safety. Since LES turbulence models are computationally time consuming when applied to real geometries, RANS models are still widely used. However, RANS models are very sensitive to the chosen turbulence parametrisation and the results can vary according to the application. In this investigation, the simulation of the wind flow around an isolated building is performed using various types of RANS turbulence models in the open source code OpenFOAM, and the results are compared with benchmark experimental data. In order to confirm the numerical accuracy of the simulations, a grid dependency analysis is performed and the convergence index and rate are calculated. Hit rates are calculated for all the cases and the models that successfully pass a validation criterion are analysed at different regions of the building roof, and the most accurate RANS models for the modelling of the flow at each region are identified. The characteristics of the wind flow at each region are also analysed from the point of view of the wind energy generation, and the most adequate wind turbine model for the wind energy exploitation at each region of the building roof is chosen.