4 resultados para mass measurement

em Universidad Politécnica de Madrid


Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper presents a new methodology for measurement of the instantaneous average exhaust mass flow rate in reciprocating internal combustion engines to be used to determinate real driving emissions on light duty vehicles, as part of a Portable Emission Measurement System (PEMS). Firstly a flow meter, named MIVECO flow meter, was designed based on a Pitot tube adapted to exhaust gases which are characterized by moisture and particle content, rapid changes in flow rate and chemical composition, pulsating and reverse flow at very low engine speed. Then, an off-line methodology was developed to calculate the instantaneous average flow, considering the ?square root error? phenomenon. The paper includes the theoretical fundamentals, the developed flow meter specifications, the calibration tests, the description of the proposed off-line methodology and the results of the validation test carried out in a chassis dynamometer, where the validity of the mass flow meter and the methodology developed are demonstrated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Increasing consumer dissatisfaction related with lack of ripeness in peach has been repeatedly reported since 1990 to the present day. There is thus, a great interest in improving the assessment of peach maturity, currently based on Magness Taylor firmness (destructive, highly variable, and time consuming) and colour (not reliable for highly coloured varieties). The present research studies as an alternative several non-destructive (ND) measurements, based on multispectral imaging, visible spectra, and low mass impact response. Their relationship with maturity, as well as the potential of their combination was studied. As a result, two rather independent (R2 = 0.3) groups of non-destructive measurements, chlorophyll related optical indexes and low mass impact (LMI) measurements, were identified. Optical measurements showed the best behaviour for assessing maturity at harvest, while LMI measurements reflected handling incidences, showing a promising potential to be used to control transport and postharvest handling.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A low-mass impact sensor for high-speed firmness sensing of fruits was built and tested. Results of tests with a rubber ball indicated that the impact measurement was not sensitive to the distance between the impactor and the impacting surface of the sample within the range of 8 to 23 mm, and was not sensitive to how the sample was held. Tests with kiwifruits and peaches show good correlation between firmness readings obtained with the impact sensor and those obtained with the penetrometer. The best correlation was between the slope of the impact curve (at mid-point) and the force-deformation firmness. Preliminary test showed that the sensor could sense fruit firmness at a speed of 5 fruits/s.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Palm juice, a common-cheap-antioxidants rich natural plant juice has been investigated for optimizing the effect of UV-radiation on the antioxidant activity using a DPPH free radical scavenging activity method. In this study separate set of samples of raw palm juice has been treated with 365 and 254 nm UV-lights (UVL) respectively for different exposure time. When exposed for 15 min with 365 nm UVL induces concentration factor of caffeic acid, whereas, 254 nm UVL induces gallic acid accumulation, but overall antioxidant activity was higher for 365 nm UVradiation. Caffeic acid and other polyphenol compounds are increased by 5.5 ± 0.5 % than normal palm juice, observed after irradiation with 365 nm UVL. Even after the exposure of UV irradiation for 15 min, did not affect on peptide bond modification of protein molecules present in palm juice, therefore a green effect of UVL is explored for the effective increase of antioxidant activity.