19 resultados para marine structural steel
em Universidad Politécnica de Madrid
Resumo:
The research is an exhaustive study of the microstructure and of the stress-strain curves of structural steel S460N at temperatures typical of a fire. It includes a fractographic study of the fracture suifaces of cylindrical specimens, tensile tested at different fire scenarios, explaining the relationship between the failure micromechanisms and temperature. The paper ends with the comparison between the experimentally found strain-stress curves with that one's proposed by the EUROCODE EC3, resulting that in the case of steel S460N these are on the side ofsafety.
Resumo:
The research is an exhaustive study of the microstructure and of the stress-strain curves of structural steel S460N at temperatures typical of a fire. It includes a fractographic study of the fracture suifaces of cylindrical specimens, tensile tested at different fire scenarios, explaining the relationship between the failure micromechanisms and temperature. The paper ends with the comparison between the experimentally found strain-stress curves with that one's proposed by the EUROCODE EC3, resulting that in the case of steel S460N these are on the side ofsafety.
Resumo:
This paper investigates the effective width of reinforced concrete flat slab structures subjected to seismic loading on the basis of dynamic shaking table tests. The study is focussed on the behavior of corner slab? column connections with structural steel I- or channel-shaped sections (shearheads) as shear punching reinforcement. To this end, a 1/2 scale test model consisting of a flat slab supported on four box-type steel columns was subjected to several seismic simulations of increasing intensity. It is found from the test results that the effective width tends to increase with the intensity of the seismic simulation, and this increase is limited by the degradation of adherence between reinforcing steel and concrete induced by the strain reversals caused by the earthquake. Also, significant differences are found between the effective width obtained from the tests and the values predicted by formula proposed in the literature. These differences are attributed to the stiffening effect provided by the steel profiles that constitute the punching shear reinforcement.
Resumo:
Para el proyecto y cálculo de estructuras metálicas, fundamentalmente pórticos y celosías de cubierta, la herramienta más comúnmente utilizada son los programas informáticos de nudos y barras. En estos programas se define la geometría y sección de las barras, cuyas características mecánicas son perfectamente conocidas, y sobre las cuales obtenemos unos resultados de cálculo concretos en cuanto a estados tensionales y de deformación. Sin embargo el otro componente del modelo, los nudos, presenta mucha mayor complejidad a la hora de establecer sus propiedades mecánicas, fundamentalmente su rigidez al giro, así como de obtener unos resultados de estados tensionales y de deformación en los mismos. Esta “ignorancia” sobre el comportamiento real de los nudos, se salva generalmente asimilando a los nudos del modelo la condición de rígidos o articulados. Si bien los programas de cálculo ofrecen la posibilidad de introducir nudos con una rigidez intermedia (nudos semirrígidos), la rigidez de cada nudo dependerá de la geometría real de la unión, lo cual, dada la gran variedad de geometrías de uniones que en cualquier proyecto se nos presentan, hace prácticamente inviable introducir los coeficientes correspondientes a cada nudo en los modelos de nudos y barras. Tanto el Eurocódigo como el CTE, establecen que cada unión tendrá asociada una curva momento-rotación característica, que deberá ser determinada por los proyectistas mediante herramientas de cálculo o procedimientos experimentales. No obstante, este es un planteamiento difícil de llevar a cabo para cada proyecto. La consecuencia de esto es, que en la práctica, se realizan extensas comprobaciones y justificaciones de cálculo para las barras de las estructuras, dejando en manos de la práctica común la solución y puesta en obra de las uniones, quedando sin justificar ni comprobar la seguridad y el comportamiento real de estas. Otro aspecto que conlleva la falta de caracterización de las uniones, es que desconocemos como afecta el comportamiento real de éstas en los estados tensionales y de deformación de las barras que acometen a ellas, dudas que con frecuencia nos asaltan, no sólo en la fase de proyecto, sino también a la hora de resolver los problemas de ejecución que inevitablemente se nos presentan en el desarrollo de las obras. El cálculo mediante el método de los elementos finitos, es una herramienta que nos permite introducir la geometría real de perfiles y uniones, y nos permite por tanto abordar el comportamiento real de las uniones, y que está condicionado por su geometría. Por ejemplo, un caso típico es el de la unión de una viga a una placa o a un soporte soldando sólo el alma. Es habitual asimilar esta unión a una articulación. Sin embargo, el modelo por elementos finitos nos ofrece su comportamiento real, que es intermedio entre articulado y empotrado, ya que se transmite un momento y el giro es menor que el del apoyo simple. No obstante, la aplicación del modelo de elementos finitos, introduciendo la geometría de todos los elementos estructurales de un entramado metálico, tampoco resulta en general viable desde un punto de vista práctico, dado que requiere invertir mucho tiempo en comparación con el aumento de precisión que obtenemos respecto a los programas de nudos y barras, mucho más rápidos en la fase de modelización de la estructura. En esta tesis se ha abordado, mediante la modelización por elementos finitos, la resolución de una serie de casos tipo representativos de las uniones más comúnmente ejecutadas en obras de edificación, como son las uniones viga-pilar, estableciendo el comportamiento de estas uniones en función de las variables que comúnmente se presentan, y que son: •Ejecución de uniones viga-pilar soldando solo por el alma (unión por el alma), o bien soldando la viga al pilar por todo su perímetro (unión total). •Disposición o no de rigidizadores en los pilares •Uso de pilares de sección 2UPN en cajón o de tipo HEB, que son los tipos de soporte utilizados en casi el 100% de los casos en edificación. Para establecer la influencia de estas variables en el comportamiento de las uniones, y su repercusión en las vigas, se ha realizado un análisis comparativo entre las variables de resultado de los casos estudiados:•Estados tensionales en vigas y uniones. •Momentos en extremo de vigas •Giros totales y relativos en nudos. •Flechas. Otro de los aspectos que nos permite analizar la casuística planteada, es la valoración, desde un punto de vista de costos de ejecución, de la realización de uniones por todo el perímetro frente a las uniones por el alma, o de la disposición o no de rigidizadores en las uniones por todo el perímetro. Los resultados a este respecto, son estrictamente desde un punto de vista económico, sin perjuicio de que la seguridad o las preferencias de los proyectistas aconsejen una solución determinada. Finalmente, un tercer aspecto que nos ha permitido abordar el estudio planteado, es la comparación de resultados que se obtienen por el método de los elementos finitos, más próximos a la realidad, ya que se tiene en cuenta los giros relativos en las uniones, frente a los resultados obtenidos con programas de nudos y barras. De esta forma, podemos seguir usando el modelo de nudos y barras, más versátil y rápido, pero conociendo cuáles son sus limitaciones, y en qué aspectos y en qué medida, debemos ponderar sus resultados. En el último apartado de la tesis se apuntan una serie de temas sobre los que sería interesante profundizar en posteriores estudios, mediante modelos de elementos finitos, con el objeto de conocer mejor el comportamiento de las uniones estructurales metálicas, en aspectos que no se pueden abordar con los programas de nudos y barras. For the project and calculation of steel structures, mainly building frames and cover lattices, the tool more commonly used are the node and bars model computer programs. In these programs we define the geometry and section of the bars, whose mechanical characteristics are perfectly known, and from which we obtain the all calculation results of stresses and displacements. Nevertheless, the other component of the model, the nodes, are much more difficulty for establishing their mechanical properties, mainly the rotation fixity coefficients, as well as the stresses and displacements. This "ignorance" about the real performance of the nodes, is commonly saved by assimilating to them the condition of fixed or articulated. Though the calculation programs offer the possibility to introducing nodes with an intermediate fixity (half-fixed nodes), the fixity of every node will depend on the real connection’s geometry, which, given the great variety of connections geometries that in a project exist, makes practically unviable to introduce the coefficients corresponding to every node in the models of nodes and bars. Both Eurocode and the CTE, establish that every connection will have a typical moment-rotation associated curve, which will have to be determined for the designers by calculation tools or experimental procedures. Nevertheless, this one is an exposition difficult to carry out for each project. The consequence of this, is that in the practice, in projects are extensive checking and calculation reports about the bars of the structures, trusting in hands of the common practice the solution and execution of the connections, resulting without justification and verification their safety and their real behaviour. Another aspect that carries the lack of the connections characterization, is that we don´t know how affects the connections real behaviour in the stresses and displacements of the bars that attack them, doubts that often assault us, not only in the project phase, but also at the moment of solving the execution problems that inevitably happen in the development of the construction works. The calculation by finite element model is a tool that allows us to introduce the real profiles and connections geometry, and allows us to know about the real behaviour of the connections, which is determined by their geometry. Typical example is a beam-plate or beam-support connection welding only by the web. It is usual to assimilate this connection to an articulation or simple support. Nevertheless, the finite element model determines its real performance, which is between articulated and fixed, since a moment is transmitted and the relative rotation is less than the articulation’s rotation. Nevertheless, the application of the finite element model, introducing the geometry of all the structural elements of a metallic structure, does not also turn out to be viable from a practical point of view, provided that it needs to invest a lot of time in comparison with the precision increase that we obtain opposite the node and bars programs, which are much more faster in the structure modelling phase. In this thesis it has been approached, by finite element modelling, the resolution of a representative type cases of the connections commonly used in works of building, since are the beam-support connections, establishing the performance of these connections depending on the variables that commonly are present, which are: •Execution of beam-support connections welding only the web, or welding the beam to the support for the whole perimeter. •Disposition of stiffeners in the supports •Use 2UPN in box section or HEB section, which are the support types used in almost 100% building cases. To establish the influence of these variables in the connections performance, and the repercussion in the beams, a comparative analyse has been made with the resulting variables of the studied cases: •Stresses states in beams and connections. •Bending moments in beam ends. •Total and relative rotations in nodes. •Deflections in beams. Another aspect that the study allows us to analyze, is the valuation, from a costs point of view, of the execution of connections for the whole perimeter opposite to the web connections, or the execution of stiffeners. The results of this analyse, are strictly from an economic point of view, without prejudice that the safety or the preferences of the designers advise a certain solution. Finally, the third aspect that the study has allowed us to approach, is the comparison of the results that are obtained by the finite element model, nearer to the real behaviour, since the relative rotations in the connections are known, opposite to the results obtained with nodes and bars programs. So that, we can use the nodes and bars models, more versatile and quick, but knowing which are its limitations, and in which aspects and measures, we must weight the results. In the last part of the tesis, are relationated some of the topics on which it would be interesting to approach in later studies, with finite elements models, in order to know better the behaviour of the structural steel connections, in aspects that cannot be approached by the nodes and bars programs.
Resumo:
The Vicario Viaduct is located in the A-44 motorway, in the South-East part of Spain. It crosses a natural gorge, near the town of Ízbor in the province of Granada. A single continuous steel concrete composite deck, 24 m wide and 175 m long, divided in two 87,5 m spans, has been built. The cross section is a single structural steel box, 8,00 m wide and 4,52 m deep. The total width of 24 m is reached adding a strut and tie system each 4,375 m on both sides of the box. The steel parts of the deck were entirely constructed in the workshop and then they were erected on site just behind one of the abutments. Finally a 27.5 m long steel nose was connected to launch the deck. The main problems have been the curved shape of the deck (1420 m radius in plan) producing a non symmetric transverse distribution of reactions on each support and the cantilever reaching 87,5 m long, producing a maximum deflection of 1500 mm
Resumo:
The writer would like to point out the existence of a very remarkable Spanish cable-stayed bridge built in 1925, wich is thus older than the first one recorded by the authors (and probably the pioneer in concrete-deck type). The Tempul Aqueduct was designed by the famous Professor Educardo Torroja. The deck is a concrete box girder sustained by two planes of 3 mm diam 37-wire double cables working at 27 kg/mm2.
Resumo:
Corrosion can affect the bond between reinforcing bars and concrete and hence the transfer of longitudinal stresses. Although a number of experimental studies on bond failure have been conducted in recent years, the findings have diverged rather widely, due primarily to differing test conditions. The present paper reports on an experimental programme consisting of eccentric pull-out tests run on corroded steel bars in specimens subjected to accelerated or natural corrosion. An axisymmetric bi-dimensional FE model with finite deformations initially developed to study bond mechanics with sound steel bars, has been enhanced to consider bond effects in corroded steel bars. The model simulation is compared to some of the experimental results for corroded and sound bars and the findings are analysed.
Resumo:
The possible deleterious effects of coiling and long time storage of coiled wires on the stress relaxation behaviour of prestressing steel wires has been checked by means of experimental work and a simple analytical model. The results show that if the requirements of Standards are fulfilled (minimum coiling diameters) these effects can be neglected. However, some other factors like previous residual stresses, long time storage or storage at high temperatures, can trigger or emphasize this damage on the material. In the authors? opinion it is recommended to control the final curvature of the wires after uncoiling prior to prestressin, as required in some Standards.
Resumo:
Prestressed structures are susceptible to relaxation losses which are of significant importance in structural design. After being manufactured, prestressing wires are coiled to make their storage and transportation easier. The possible deleterious effects of this operation on the stress relaxation behavior of prestressing steel wires are usually neglected, though it has been noticed by manufacturers and contractors that when relaxation tests are carried out after a long-time storage, on occasions relaxation losses are higher than those measured a short time after manufacturing. The influence of coiling on the relaxation losses is checked by means of experimental work and confirmed with a simple analytical model. The results show that some factors like initial residual stresses, excessively long-time storage or storage at high temperatures, can trigger or accentuate this damage. However, it is also shown that if the requirements of standards are fulfilled (minimum coiling diameters) these effects can be neglected.
Resumo:
The possible deleterious effects of coiling and long-term storage of coiled wires on the stress relaxation behaviour of prestressing steel wires has been checked by means of experimental work and a simple analytical model. The results show that if the requirements of standards are fulfilled (minimum coiling diameters), these effects can be neglected. However, some other factors, such as previous residual stresses, long-term storage or storage at high temperatures, can trigger or emphasize this damage to the material. In the authors' opinion, checking the final curvature of the wires after uncoiling prior to prestressing, as required in some standards, is to be recommended.
Resumo:
The purpose of this paper is to provide information on the behaviour of steel prestressing wires under likely conditions that could be expected during a fire or impact loads. Four loadings were investigated: a) the influence of strain rate – from 10–3 to 600 s–1 – at room temperature, b) the influence of temperature – from 24 to 600 °C – at low strain rate, c) the influence of the joint effect of strain rate and temperature, and d) damage after three plausible fire scenarios. At room temperature it was found that using “static” values is a safe option. At high temperatures our results are in agreement with design codes. Regarding the joint effect of temperature and strain rate, mechanical properties decrease with increasing temperature, although for a given temperature, yield stress and tensile strength increase with strain rate. The data provided can be used profitably to model the mechanical behaviour of steel wires under different scenarios.
Resumo:
In the present work a seismic retrofitting technique is proposed for masonry infilled reinforced concrete frames based on the replacement of infill panels by K-bracing with vertical shear link. The performance of this technique is evaluated through experimental tests. A simplified numerical model for structural damage evaluation is also formulated according to the notions and principles of continuum damage mechanics. The proposed model is calibrated with the experimental results. The experimental results have shown an excellent energy dissipation capacity with the proposed technique. Likewise, the numerical predictions with the proposed model are in good agreement with experimental results.
Resumo:
The adhesives used for applications in marine environments are subject to particular chemical conditions, which are mainly characterised by an elevated chlorine ion content and intermittent wetting/drying cycles, among others.These conditions can limit the use of adhesives due to the degradation processes that they experience. In this work, the chemical degradation of two different polymers, polyurethane and vinylester, was studied in natural seawater under immersion for different periods of time.The diffusion coefficients and concentration profiles of water throughout the thickness of the adhesiveswere obtained.Microstructural changes in the polymer due to the action of water were observed by SEM, and the chemical degradation of the polymer was monitored with the Fourier transform infrared spectroscopy (FTIR) and differential scanning calorimetry (DSC). The degradation of the mechanical properties of the adhesive was determined by creep tests withMixed Cantilever Beam (MCB) specimens at different temperatures. After 180 days of immersion of the specimens, it was concluded that the J-integral value (depending on the strain) implies a loss of stiffness of 51% and a decrease in the failure load of 59% for the adhesive tested.
Resumo:
Apple fruits, cv. Granny Smith, were subjected to mechanical impact and compression loads utilizing a steel rod with a spherical tip 19 mm diameter, 50.6 g mass. Energies applied were low enough to produce enzymatic reaction: 0.0120 J for impact, and 0.0199 J for compression. Bruised material was cut and examined with a transmission electron microscope. In both compression and impact, bruises showed a central region located in the flesh parenchyma, at a distance that approximately equalled the indentor tip radius. The parenchyma cells of this region were more altered than cells from the epidermis and hypodermis. Tissues under compression presented numerous deformed parenchyma cells with broken tonoplasts and tissue degradation as predicted by several investigators. The impacted cells supported different kinds of stresses than compressed cells, resulting in the formation of intensive vesiculation, either in the vacuole or in the middle lamella region between cell walls of adjacent cells. A large proportion of parenchyma cells completely split or had initiated splitting at the middle lamella. Bruising may develop with or without cell rupture. Therefore, cell wall rupture is not essential for the development of a bruise, at least the smallest one, as predicted previously
Resumo:
Prestressed structures are susceptible to relaxation losses which are of significant importance in structural design. After being manufactured, prestressing wires are coiled to make their storage and transportation easier. The possible deleterious effects of this operation on the stress relaxation behavior of prestressing steel wires are usually neglected, though it has been noticed by manufacturers and contractors that when relaxation tests are carried out after a long-time storage, on occasions relaxation losses are higher than those measured a short time after manufacturing. The influence of coiling on the relaxation losses is checked by means of experimental work and confirmed with a simple analytical model. The results show that some factors like initial residual stresses, excessively long-time storage or storage at high temperatures,can trigger or accentuate this damage. However, it is also shown that if the requirements of standards are fulfilled (minimum coiling diameters) these effects can be neglected.