8 resultados para leaf tissue density
em Universidad Politécnica de Madrid
Resumo:
The annual grass Brachypodium distachyon has been recently recognized as the model plant for functional genomics of temperate grasses, including cereals of economic relevance like wheat and barley. Sixty-two lines of B. distachyon were assessed for response to drought stress and heat tolerance. All these lines, except the reference genotype BD21, derive from specimens collected in 32 distinct locations of the Iberian Peninsula, covering a wide range of geo- climatic conditions. Sixteen lines of Brachypodium hybridum, an allotetraploid closely related to B. distachyon were used as reference of abiotic-stress well-adapted genotypes. Drought tolerance was assessed in a green-house trial. At the rosette-stage, no irrigation was applied to treated plants whereas their replicates at the control were maintained well watered during all the experiment. Thermographic images of treated and control plants were taken after 2 and 3 weeks of drought treatment, when stressed plants showed medium and extreme wilting symptoms. The mean leaf temperature of stressed (LTs) and control (LTc) plants was estimated based upon thermographic records from selected pixels (183 per image) that strictly correspond to leaf tissue. The response to drought was based on the analysis of two parameters: LTs and the thermal difference (TD) between stressed and control plants (LTs – LTc). The response to heat stress was based on LTc. Comparison of the mean values of these parameters showed that: 1) Genotypes better adapted to drought (B. hybridum lines) presented a higher LTs and TD than B. distachyon lines. 2) Under high temperature conditions, watered plants of B. hybridum lines maintained lower LTc than those of B. distachyon. Those results suggest that in these species adaptation to drought is linked to a more efficient stomata regulation: under water stress stomata are closed, increasing foliar temperature but also water use efficiency by reducing transpiration. With high temperature and water availability the results are less definite, but still seems that opening stomata allow plants to increase transpiration and therefore to diminish foliar temperature.
Resumo:
Ammonia emissions from livestock production can have negative impacts on nearby protected sites and ecosystems that are sensitive to eutrophication and acidification. Trees are effective scavengers of both gaseous and particulate pollutants from the atmosphere making tree belts potentially effective landscape features to support strategies aiming to reduce ammonia impacts. This research used the MODDAS-THETIS a coupled turbulence and deposition turbulence model, to examine the relationships between tree canopy structure and ammonia capture for three source types?animal housing, slurry lagoon, and livestock under a tree canopy. By altering the canopy length, leaf area index, leaf area density, and height of the canopy in the model the capture efficiencies varied substantially. A maximum of 27% of the emitted ammonia was captured by tree canopy for the animal housing source, for the slurry lagoon the maximum was 19%, while the livestock under trees attained a maximum of 60% recapture. Using agro-forestry systems of differing tree structures near ?hot spots? of ammonia in the landscape could provide an effective abatement option for the livestock industry that complements existing source reduction measures.
Resumo:
El cambio climático y sus efectos requieren con urgencia el desarrollo de estrategias capaces no solo de mitigar pero también permitir la adaptación de los sistemas afectados por este fenómeno a los cambios que están provocando a nivel mundial. Olas de calor más largas y frecuentes, inundaciones, y graves sequías aumentan la vulnerabilidad de la población, especialmente en asentamientos urbanos. Este fenómeno y sus soluciones potenciales han sido ampliamente estudiados en las últimas décadas desde diferentes perspectivas y escalas que analizan desde el fenómeno regional de isla de calor al aumento de la intensidad energética necesaria en los edificios para mantener las condiciones de confort en los escenarios de calentamiento que se predicen. Su comprensión requiere el entendimiento de este fenómeno y un profundo análisis de las estrategias que pueden corregirlo y adaptarse a él. En la búsqueda de soluciones a este problema, las estrategias que incorporan sistemas naturales tales como las cubiertas ajardinadas, las fachadas vegetadas y bosques urbanos, se presentan como opciones de diseño capaces de proporcionan múltiples servicios al ecosistema urbano y de regular y hacer frente a los efectos del cambio climático. Entre los servicios que aportan estos sistemas naturales se incluyen la gestión de agua de tormentas, el control del efecto isla de calor, la mejora de la calidad del aire y del agua, el aumento de la diversidad, y como consecuencia de todo lo anterior, la reducción de la huella ecológica de las ciudades. En la última década, se han desarrollado múltiples estudios para evaluar y cuantificar los servicios al ecosistema proporcionados por las infraestructuras verdes, y específicamente las cubiertas ajardinadas, sin embargo, determinados servicios como la capacidad de la regulación del microclima urbano no ha sido apenas estudiados. La mayor parte de la literatura en este campo la componen estudios relacionados con la capacidad de las cubiertas ajardinadas de reducir el efecto de la isla de calor, en una escala local, o acerca de la reducción de la demanda energética de refrigeración debida a la instalación de cubiertas ajardinadas en la escala de edificio. La escala intermedia entre estos dos ámbitos, la calle, desde su ámbito habitable cercano al suelo hasta el límite superior del cañón urbano que configura, no han sido objeto detallado de estudio por lo que es esta escala el objeto de esta tesis doctoral. Esta investigación tiene como objeto contribuir en este campo y aportar un mayor entendimiento a través de la cuantificación del impacto de las cubiertas ajardinadas sobre la temperatura y humedad en el cañón urbano en la escala de calle y con un especial foco en el nivel peatonal. El primer paso de esta investigación ha sido la definición del objeto de estudio a través del análisis y revisión de trabajos tanto teóricos como empíricos que investigan los efectos de cubiertas ajardinadas en el entorno construido, entendidas como una herramienta para la adaptación y mitigación del impacto del cambio climático en las ciudades. La literatura analizada, revela el gran potencial de los sistemas vegetales como herramientas para el diseño pasivo puesto que no solo son capaces de mejorar las condiciones climáticas y microclimaticas en las ciudades reduciendo su demanda energética, sino también la necesidad de mayor análisis en la escala de calle donde confluyen el clima, las superficies urbanas y materiales y vegetación. Este análisis requiere una metodología donde se integren la respuesta térmica de edificios, las variaciones en los patrones de viento y radiación, y la interacción con la vegetación, por lo que un análisis cuantitativo puede ayudar a definir las estrategias más efectivas para lograr espacios urbanos más habitables. En este contexto, el objetivo principal de esta investigación ha sido la evaluación cuantitativa del impacto de la cubierta ajardinada en el microclima urbano a escala de barrio en condiciones de verano en los climas mediterráneos continentales. Para el logro de este objetivo, se ha seguido un proceso que persigue identificar los modelos y herramientas de cálculo capaces de capturar el efecto de la cubierta ajardinada sobre el microclima, identificar los parámetros que potencian o limitan este efecto, y cuantificar las variaciones que microclima creado en el cañón urbano produce en el consumo de energía de los edificios que rodean éste espacio. La hipótesis principal detrás de esta investigación y donde los objetivos anteriores se basan es el siguiente: "una cubierta ajardinada instalada en edificios de mediana altura favorece el establecimiento de microclimas a nivel peatonal y reduce las temperaturas en el entorno urbano donde se encuentra”. Con el fin de verificar la hipótesis anterior y alcanzar los objetivos propuestos se ha seguido la siguiente metodología: • definición del alcance y limitaciones del análisis • Selección de las herramientas y modelos de análisis • análisis teórico de los parámetros que afectan el efecto de las cubiertas ajardinadas • análisis experimental; • modelización energética • conclusiones y futuras líneas de trabajo Dada la complejidad de los fenómenos que intervienen en la generación de unas determinadas condiciones microclimáticas, se ha limitado el objeto de este estudio a las variables de temperatura y humedad, y sólo se han tenido en cuenta los componentes bióticos y abióticos del sistema, que incluyen la morfología, características superficiales del entorno estudiado, así como los elementos vegetales. Los componentes antrópicos no se han incluido en este análisis. La búsqueda de herramientas adecuadas para cumplir con los objetivos de este análisis ha concluido en la selección de ENVI-met v4 como el software más adecuado para esta investigación por su capacidad para representar los complejos fenómenos que caracterizan el microclima en cañones urbanos, en una escala temporal diaria y con unas escala local de vecindario. Esta herramienta supera el desafío que plantean los requisitos informáticos de un cálculo completo basado en elementos finitos realizados a través de herramientas de dinámica de fluidos computacional (CFD) que requieren una capacidad de cálculo computacional y tiempo privativos y en una escala dimensional y temporal limitada a esta capacidad computacional lo que no responde a los objetivos de esta investigación. ENVI-met 4 se basa es un modelo tridimensional del micro clima diseñado para simular las interacciones superficie-planta-aire en entornos urbanos. Basado en las ecuaciones fundamentales del equilibrio que representan, la conservación de masa, energía y momento. ENVI-met es un software predictivo, y como primer paso ha requerido la definición de las condiciones iniciales de contorno que se utilizan como punto de partida por el software para generar su propio perfil de temperatura y humedad diaria basada en la localización de la construcción, geometría, vegetación y las superficies de características físicas del entorno. La geometría de base utilizada para este primer análisis se ha basado en una estructura típica en cuanto al trazado urbano situada en Madrid que se ha simulado con una cubierta tradicional y una cubierta ajardinada en sus edificios. La estructura urbana seleccionada para este análisis comparativo es una red ortogonal con las calles principales orientadas este-oeste. El edificio típico que compone el vecindario se ha definido como “business as usual” (BAU) y se ha definido con una cubierta de baldosa de hormigón estándar, con un albedo 0.3, paredes con albedo 0.2 (construcción de muro de ladrillo típico) y cerramientos adiabáticos para evitar las posibles interferencias causadas por el intercambio térmico con el ambiente interior del edificio en los resultados del análisis. Para el caso de la cubierta ajardinada, se mantiene la misma geometría y características del edificio con excepción de la cobertura superficial de la azotea. Las baldosas de hormigón se han modificado con una cubierta ajardinada extensiva cubierta con plantas xerófilas, típicas en el clima de Madrid y caracterizado por su índice de densidad foliar, el “leaf area density” (LAD), que es la superficie total de superficie de hojas por unidad de volumen (m2/m3). El análisis se centra en los cañones urbanos entendidos como el espacio de calle comprendido entre los límites geométricos de la calle, verticales y horizontales, y el nivel superior de la cota urbana nivel de cubiertas. Los escenarios analizados se basan en la variación de la los principales parámetros que según la literatura analizada condicionan las variaciones microclimáticas en el ámbito urbano afectado por la vegetación, la velocidad del viento y el LAD de la azotea. Los resultados han sido registrados bajo condiciones de exposición solar diferentes. Las simulaciones fueron realizadas por los patrones de viento típico de verano, que para Madrid se caracterizan por vientos de componente suroeste que van desde 3 a 0 m/s. las simulaciones fueron realizadas para unas condiciones climáticas de referencia de 3, 2, 1 y 0 m/s a nivel superior del cañón urbano, como condición de contorno para el análisis. Los resultados calculados a 1,4 metros por encima del nivel del suelo, en el espacio habitado, mostraron que el efecto de la cubierta ajardinada era menor en condiciones de contorno con velocidades de viento más altas aunque en ningún caso el efecto de la cubierta verde sobre la temperatura del aire superó reducciones de temperatura de aire superiores a 1 º C. La humedad relativa no presentó variaciones significativas al comparar los diferentes escenarios. Las simulaciones realizadas para vientos con velocidad baja, entre 0 y 1 m/s mostraron que por debajo de 0.5 m/s la turbulencia del modelo aumentó drásticamente y se convirtió en el modelo inestable e incapaz de producir resultados fiables. Esto es debido al modelo de turbulencia en el software que no es válido para velocidades de viento bajas, lo que limita la capacidad de ENVI-met 4 para realizar simulaciones en estas condiciones de viento y es una de las principales conclusiones de este análisis en cuanto a la herramienta de simulación. También se comprobó el efecto de las densidades de la densidad de hoja (LAD) de los componentes vegetales en el modelo en la capa de aire inmediatamente superior a la cubierta, a 0,5 m sobre este nivel. Se compararon tres alternativas de densidad de hoja con la cubierta de baldosa de hormigón: el techo verde con LAD 0.3 (hierba típica o sedum), LAD 1.5 (plantas mixtas típicas) y LAD 2.5 (masa del árbol). Los resultados mostraron diferencias de temperatura muy relevante entre las diferentes alternativas de LAD analizadas. Los resultados muestran variaciones de temperatura que oscilan entre 3 y 5 º C al comparar el estándar de la azotea concreta con albedo 0, 3 con el techo con vegetación y vegetación densa, mostrando la importancia del LAD en la cuantificación de los efectos de las cubiertas vegetales en microclima circundante, lo que coincide con los datos reportados en la literatura existente y con los estudios empíricos analizados. Los resultados de los análisis teóricos han llegado a las siguientes conclusiones iniciales relacionadas con la herramienta de simulación y los resultados del modelo: En relación con la herramienta ENVI-met, se han observado limitaciones para el análisis. En primer lugar, la estructura rígida de la geometría, las bases de datos y el tamaño de la cuadrícula, limitan la escala y resolución de los análisis no permitiendo el desarrollo de grandes zonas urbanas. Por otro lado la estructura de ENVI-met permite el desarrollo de este tipo de simulación tan complejo dentro de tiempos razonables de cálculo y requerimientos computacionales convencionales. Otra limitación es el modelo de turbulencia del software, que no modela correctamente velocidades de viento bajas (entre 0 y 1 m/s), por debajo de 0,5 m/s el modelo da errores y no es estable, los resultados a estas velocidades no son fiables porque las turbulencias generadas por el modelo hacen imposible la extracción de patrones claros de viento y temperatura que permitan la comparación entre los escenarios de cubierta de hormigón y ajardinada. Además de las limitaciones anteriores, las bases de datos y parámetros de entrada en la versión pública del software están limitados y la complejidad de generar nuevos sistemas adaptándolos al edificio o modelo urbano que se quiera reproducir no es factible salvo en la versión profesional del software. Aparte de las limitaciones anteriores, los patrones de viento y perfiles de temperatura generados por ENVI-met concuerdan con análisis previos en los que se identificaban patrones de variación de viento y temperaturas en cañones urbanos con patrones de viento, relación de aspecto y dimensiones similares a los analizados en esta investigación. Por lo tanto, el software ha demostrado una buena capacidad para reproducir los patrones de viento en los cañones de la calle y capturar el efecto de enfriamiento producido por la cubierta verde en el cañón. En relación con el modelo, el resultado revela la influencia del viento, la radiación y el LAD en la temperatura del aire en cañones urbanos con relación de aspecto comprendida entre 0,5 y 1. Siendo el efecto de la cubierta verde más notable en cañones urbanos sombreados con relación de aspecto 1 y velocidades de viento en el nivel de “canopy” (por encima de la cubierta) de 1 m/s. En ningún caso las reducciones en la temperatura del aire excedieron 1 º C, y las variaciones en la humedad relativa no excedieron 1% entre los escenarios estudiados. Una vez que se han identificado los parámetros relevantes, que fueron principalmente la velocidad del viento y el LAD, se realizó un análisis experimental para comprobar los resultados obtenidos por el modelo. Para éste propósito se identificó una cubierta ajardinada de grandes dimensiones capaz de representar la escala urbana que es el objeto del estudio. El edificio usado para este fin fue el parking de la terminal 4 del aeropuerto internacional de Madrid. Aunque esto no es un área urbana estándar, la escala y la configuración del espacio alrededor del edificio fueron considerados aceptables para el análisis por su similitud con el contexto urbano objeto de estudio. El edificio tiene 800 x 200 m, y una altura 15 m. Está rodeado de vías de acceso pavimentadas con aceras conformando un cañón urbano limitado por el edificio del parking, la calle y el edificio de la terminal T4. El aparcamiento está cerrado con fachadas que configuran un espacio urbano de tipo cañón, con una relación de aspecto menor que 0,5. Esta geometría presenta patrones de viento y velocidad dentro del cañón que difieren ligeramente de los generados en el estudio teórico y se acercan más a los valores a nivel de canopo sobre la cubierta del edificio, pero que no han afectado a la tendencia general de los resultados obtenidos. El edificio cuenta con la cubierta ajardinada más grande en Europa, 12 Ha cubiertas por con una mezcla de hierbas y sedum y con un valor estimado de LAD de 1,5. Los edificios están rodeados por áreas plantadas en las aceras y árboles de sombra en las fachadas del edificio principal. El efecto de la cubierta ajardinada se evaluó mediante el control de temperaturas y humedad relativa en el cañón en un día típico de verano. La selección del día se hizo teniendo en cuenta las predicciones meteorológicas para que fuesen lo más semejantes a las condiciones óptimas para capturar el efecto de la cubierta vegetal sobre el microclima urbano identificadas en el modelo teórico. El 09 de julio de 2014 fue seleccionado para la campaña de medición porque las predicciones mostraban 1 m/s velocidad del viento y cielos despejados, condiciones muy similares a las condiciones climáticas bajo las que el efecto de la cubierta ajardinada era más notorio en el modelo teórico. Las mediciones se registraron cada hora entre las 9:00 y las 19:00 en 09 de julio de 2014. Temperatura, humedad relativa y velocidad del viento se registraron en 5 niveles diferentes, a 1.5, 4.5, 7.5, 11.5 y 16 m por encima del suelo y a 0,5 m de distancia de la fachada del edificio. Las mediciones fueron tomadas en tres escenarios diferentes, con exposición soleada, exposición la sombra y exposición influenciada por los árboles cercanos y suelo húmedo. Temperatura, humedad relativa y velocidad del viento se registraron con un equipo TESTO 410-2 con una resolución de 0,1 ºC para temperatura, 0,1 m/s en la velocidad del viento y el 0,1% de humedad relativa. Se registraron las temperaturas de la superficie de los edificios circundantes para evaluar su efecto sobre los registros usando una cámara infrarroja FLIR E4, con resolución de temperatura 0,15ºC. Distancia mínima a la superficie de 0,5 m y rango de las mediciones de Tª de - 20 º C y 250 º C. Los perfiles de temperatura extraídos de la medición in situ mostraron la influencia de la exposición solar en las variaciones de temperatura a lo largo del día, así como la influencia del calor irradiado por las superficies que habían sido expuestas a la radiación solar así como la influencia de las áreas de jardín alrededor del edificio. Después de que las medidas fueran tomadas, se llevaron a cabo las siguientes simulaciones para evaluar el impacto de la cubierta ajardinada en el microclima: a. estándar de la azotea: edificio T4 asumiendo un techo de tejas de hormigón con albedo 0.3. b. b. cubierta vegetal : T4 edificio asumiendo una extensa cubierta verde con valor bajo del LAD (0.5)-techo de sedum simple. c. c. cubierta vegetal: T4 edificio asumiendo una extensa cubierta verde con alta joven valor 1.5-mezcla de plantas d. d. cubierta ajardinada más vegetación nivel calle: el edificio T4 con LAD 1.5, incluyendo los árboles existentes a nivel de calle. Este escenario representa las condiciones actuales del edificio medido. El viento de referencia a nivel de cubierta se fijó en 1 m/s, coincidente con el registro de velocidad de viento en ese nivel durante la campaña de medición. Esta velocidad del viento se mantuvo constante durante toda la campaña. Bajo las condiciones anteriores, los resultados de los modelos muestran un efecto moderado de azoteas verdes en el microclima circundante que van desde 1 º a 2 º C, pero una contribución mayor cuando se combina con vegetación a nivel peatonal. En este caso las reducciones de temperatura alcanzan hasta 4 ºC. La humedad relativa sin embargo, no presenta apenas variación entre los escenarios con y sin cubierta ajardinada. Las temperaturas medidas in situ se compararon con resultados del modelo, mostrando una gran similitud en los perfiles definidos en ambos casos. Esto demuestra la buena capacidad de ENVI-met para reproducir el efecto de la cubierta ajardinada sobre el microclima y por tanto para el fin de esta investigación. Las diferencias más grandes se registraron en las áreas cercanas a las zonas superiores de las fachadas que estaban más expuestas a la radiación del sol y también el nivel del suelo, por la influencia de los pavimentos. Estas diferencias se pudieron causar por las características de los cerramientos en el modelo que estaban limitados por los datos disponibles en la base de datos de software, y que se diferencian con los del edificio real. Una observación importante derivada de este estudio es la contribución del suelo húmedo en el efecto de la cubierta ajardinada en la temperatura del aire. En el escenario de la cubierta ajardinada con los arboles existentes a pie de calle, el efecto del suelo húmedo contribuye a aumentar las reducciones de temperatura hasta 4.5ºC, potenciando el efecto combinado de la cubierta ajardinada y la vegetación a pie de calle. Se realizó un análisis final después de extraer el perfil horario de temperaturas en el cañón urbano influenciado por el efecto de las cubiertas ajardinadas y los árboles. Con esos perfiles modificados de temperatura y humedad se desarrolló un modelo energético en el edificio asumiendo un edificio cerrado y climatizado, con uso de oficinas, una temperatura de consigna de acuerdo al RITE de 26 ºC, y con los sistemas por defecto que establece el software para el cálculo de la demanda energética y que responden a ASHRAE 90.1. El software seleccionado para la simulación fue Design Builder, por su capacidad para generar simulaciones horarias y por ser una de las herramientas de simulación energética más reconocidas en el mercado. Los perfiles modificados de temperatura y humedad se insertaron en el año climático tipo y se condujo la simulación horaria para el día definido, el 9 de Julio. Para la simulación se dejaron por defecto los valores de conductancia térmica de los cerramientos y la eficiencia de los equipos de acuerdo a los valores que fija el estándar ASHRAE para la zona climática de Madrid, que es la 4. El resultado mostraba reducciones en el consumo de un día pico de hasta un 14% de reducción en las horas punta. La principal conclusión de éste estudio es la confirmación del potencial de las cubiertas ajardinadas como una estrategia para reducir la temperatura del aire y consumo de energía en los edificios, aunque este efecto puede ser limitado por la influencia de los vientos, la radiación y la especie seleccionada para el ajardinamiento, en especial de su LAD. Así mismo, en combinación con los bosques urbanos su efecto se potencia e incluso más si hay pavimentos húmedos o suelos porosos incluidos en la morfología del cañón urbano, convirtiéndose en una estrategia potencial para adaptar los ecosistemas urbanos el efecto aumento de temperatura derivado del cambio climático. En cuanto a la herramienta, ENVI-met se considera una buena opción para éste tipo de análisis dada su capacidad para reproducir de un modo muy cercano a la realidad el efecto de las cubiertas. Aparte de ser una herramienta validada en estudios anteriores, en el caso experimental se ha comprobado por medio de la comparación de las mediciones con los resultados del modelo. A su vez, los resultados y patrones de vientos generados en los cañones urbanos coinciden con otros estudios similares, concluyendo por tanto que es un software adecuado para el objeto de esta tesis doctoral. Como líneas de investigación futura, sería necesario entender el efecto de la cubierta ajardinada en el microclima urbano en diferentes zonas climáticas, así como un mayor estudio de otras variables que no se han observado en este análisis, como la temperatura media radiante y los indicadores de confort. Así mismo, la evaluación de otros parámetros que afectan el microclima urbano tales como variables geométricas y propiedades superficiales debería ser analizada en profundidad para tener un resultado que cubra todas las variables que afectan el microclima en el cañón urbano. ABSTRACT Climate Change is posing an urgency in the development of strategies able not only to mitigate but also adapt to the effects that this global problem is evidencing around the world. Heat waves, flooding and severe draughts increase the vulnerability of population, and this is especially critical in urban settlements. This has been extensively studied over the past decades, addressed from different perspectives and ranging from the regional heat island analysis to the building scale. Its understanding requires physical and dimensional analysis of this broad phenomenon and a deep analysis of the factors and the strategies which can offset it. In the search of solutions to this problem, green infrastructure elements such as green roofs, walls and urban forests arise as strategies able provide multiple regulating ecosystem services to the urban environment able to cope with climate change effects. This includes storm water management, heat island effect control, and improvement of air and water quality. Over the last decade, multiple studies have been developed to evaluate and quantify the ecosystem services provided by green roofs, however, specific regulating services addressing urban microclimate and their impact on the urban dwellers have not been widely quantified. This research tries to contribute to fill this gap and analyzes the effects of green roofs and urban forests on urban microclimate at pedestrian level, quantifying its potential for regulating ambient temperature in hot season in Mediterranean –continental climates. The study is divided into a sequence of analysis where the critical factors affecting the performance of the green roof system on the microclimate are identified and the effects of the green roof is tested in a real case study. The first step has been the definition of the object of study, through the analysis and review of theoretical and empirical papers that investigate the effects of covers landscaped in the built environment, in the context of its use as a tool for adaptation and mitigation of the impact of climate change on cities and urban development. This literature review, reveals the great potential of the plant systems as a tool for passive design capable of improving the climatic and microclimatic conditions in the cities, as well as its positive impact on the energy performance of buildings, but also the need for further analysis at the street scale where climate, urban surfaces and materials, and vegetation converge. This analysis requires a methodology where the thermal buildings response, the variations in the patterns of wind and the interaction of the vegetation are integrated, so a quantitative analysis can help to define the most effective strategies to achieve liveable urban spaces and collaterally, , the improvement of the surrounding buildings energy performance. In this specific scale research is needed and should be customized to every climate, urban condition and nature based strategy. In this context, the main objective for this research was the quantitative assessment of the Green roof impact on the urban microclimate at a neighbourhood scale in summer conditions in Mediterranean- continental climates. For the achievement of this main objective, the following secondary objectives have been set: • Identify the numerical models and calculation tools able to capture the effect of the roof garden on the microclimate. • Identify the enhancing or limiting parameter affecting this effect. • Quantification of the impact of the microclimate created on the energy consumption of buildings surrounding the street canyon analysed. The main hypothesis behind this research and where the above objectives are funded on is as follows: "An extensive roof installed in medium height buildings favours the establishment of microclimates at the pedestrian level and reduces the temperatures in the urban environment where they are located." For the purpose of verifying the above hypothesis and achieving the proposed objectives the following methodology has been followed: - Definition of hypothesis and objectives - Definition of the scope and limitations - Theoretical analysis of parameters affecting gren roof performance - Experimental analysis; - Energy modelling analyisis - Conclusions and future lines of work The search for suitable tools and models for meeting the objectives of this analysis has led to ENVI-met v4 as the most suitable software for this research. ENVI met is a three-dimensional micro-climate model designed to simulate the surface-plant-air interactions in urban environments. Based in the fundamental equations representing, mass, energy and momentum conservation, the software has the capacity of representing the complex phenomena characterizing the microclimate in urban canyons, overcoming the challenge posed by the computing requirements of a full calculus based on finite elements done via traditional computational fluid dynamics tools. Once the analysis tool has been defined, a first set of analysis has been developed to identify the main parameters affecting the green roof influence on the microclimate. In this analysis, two different scenarios are compared. A neighborhood with standard concrete tile roof and the same configuration substituting the concrete tile by an extensive green roof. Once the scenarios have been modeled, different iterations have been run to identify the influence of different wind patterns, solar exposure and roof vegetation type on the microclimate, since those are the most relevant variables affecting urban microclimates. These analysis have been run to check the conditions under which the effects of green roofs get significance. Since ENVI-met V4 is a predictive software, the first step has been the definition of the initial weather conditions which are then used as starting point by the software, which generates its own daily temperature and humidity profile based on the location of the building, geometry, vegetation and the surfaces physical characteristics. The base geometry used for this first analysis has been based on a typical urban layout structure located in Madrid, an orthogonal net with the main streets oriented East-West to ease the analysis of solar radiation in the different points of the model. This layout represents a typical urban neighborhood, with street canyons keeping an aspect ratio between 0.5 and 1 and high sky view factor to ensure correct sun access to the streets and buildings and work with typical wind flow patterns. Finally, the roof vegetation has been defined in terms of foliage density known as Leaf Area Density (LAD) and defined as the total one-sided leaf area per unit of layer volume. This index is the most relevant vegetation characteristic for the purpose of calculating the effect of vegetation on wind and solar radiation as well as the energy consumed during its metabolic processes. The building as usual (BAU) configuring the urban layout has been defined with standard concrete tile roofs, considering 0.3 albedo. Walls have been set with albedo 0.2 (typical brick wall construction) and adiabatic to avoid interference caused by thermal interchanges with the building indoor environment. For the proposed case, the same geometry and building characteristics have been kept. The only change is the roof surface coverage. The gravel on the roof has been changed with an extensive green roof covered with drought tolerant plants, typical in Madrid climate, and characterized by their LAD. The different scenarios analysed are based in the variation of the wind speed and the LAD of the roof. The results have been recorded under different sun exposure conditions. Simulations were run for the typical summer wind patterns, that for Madrid are characterized by South-west winds ranging from 3 to 0 m/s. Simulations were run for 3, 2, 1 and 0 m/s at urban canopy level. Results taken at 1.4 m above the ground showed that the green roof effect was lower with higher wind speeds and in any case the effect of the green roof on the air temperatures exceeded air temperature reductions higher than 1ºC. Relative humidity presented no variations when comparing the different scenarios. For the analysis at 0m/s, ENVI-met generated error and no results were obtained. Different simulations showed that under 0.5 m/s turbulence increased dramatically and the model became unstable and unable to produce reliable results. This is due to the turbulence model embedded in the software which is not valid for low wind speeds (below 1 m/s). The effect of the different foliage densities was also tested in the model. Three different alternatives were compared against the concrete roof: green roof with LAD 0.3 ( typical grass or sedum), 1.5 (typical mixed plants) and 2.5 (tree mass). The results showed very relevant temperature differences between the different LAD alternatives analyzed. Results show temperature variations ranging between 3 and 5 ºC when comparing the standard concrete roof with albedo 0, 3 with the vegetated roof and vegetated mass, showing the relevance of the LAD on the effects of green roofs on microclimate. This matches the data reported in existing literature and empirical studies and confirms the relevance of the LAD in the roof effect on the surrounding microclimate. The results of the theoretical analysis have reached the following initial conclusions related to both, the simulation tool and the model results: • In relation to the tool ENVI-met, some limitations for the analysis have been observed. In first place, the rigid structure of the geometry, the data bases and the grid size, limit the scale and resolution of the analysis not allowing the development of large urban areas. On the other hand the ENVI-met structure enables the development of this type of complex simulation within reasonable times and computational requirements for the purpose of this analysis. Additionally, the model is unable to run simulations at wind speeds lower than 0.5 m/s, and even at this speed, the results are not reliable because the turbulences generated by the model that made impossible to extract clear temperature differences between the concrete and green roof scenarios. Besides the above limitations, the wind patterns and temperature profiles generated by ENVImet are in agreement with previous analysis identifying wind patterns in urban canyons with similar characteristics and aspect ratio. Therefore the software has shown a good capacity for reproducing the wind effects in the street canyons and seems to capture the cooling effect produced by the green roof. • In relation to the model, the results reveals the influence of wind, radiation and LAD on air temperature in urban canyons with aspect ratio comprised between 0.5 and 1. Being the effect of the green roof more noticeable in shaded urban canyons with aspect ratio 1 and wind speeds of 1 m/s. In no case the reductions in air temperature exceeded 1ºC. Once the relevant parameters have been identified, mainly wind speed and LAD, an experimental analysis was conducted to test the results obtained by the model. For this purpose a large green roof was identified, able to represent the urban scale which is the object of the studio. The building identified for this purpose was the terminal 4, parking building of the international Madrid Airport. Even though this is not a standard urban area, the scale and configuration of the space around the building were deemed as acceptable for the analysis. The building is an 800x200 m, 15 m height parking building, surrounded by access paved paths and the terminal building. The parking is enclosed with facades that configure an urban canyon-like space, although the aspect ratio is lower than 0.5 and the wind patterns might differ from the theoretical model run. The building features the largest green roof in Europe, a 12 Ha extensive green roof populated with a mix of herbs and sedum with a LAD of 1.5. The buildings are surrounded by planted areas at the sidewalk and trees shading the main building facades. Green roof performance was evaluated by monitoring temperatures and relative humidity in the canyon in a typical summer day. The day selection was done taking into account meteorological predictions so the weather conditions on the measurement day were as close as possible as the optimal conditions identified in terms of green roof effects on the urban canyon. July 9th 2014 was selected for the measurement campaign because the predictions showed 1 m/s wind speed and sunny sky, which were very similar to the weather conditions where the effect of the green roof was most noticeable in the theory model. Measurements were registered hourly from 9:00am to 19:00 on July 9th 2014. Temperature, relative humidity and wind speed were recorded at 5 different levels, at 1.5, 4.5, 7.5, 11.5 and 16 m above ground and at 0.5 m distance from the building façade. Measurements were taken in three different scenarios, sunny exposure, shaded exposure, and shaded exposure influenced by nearby trees and moist soil. Temperature, relative humidity and wind speed were registered using a TESTO 410-2 anemometer, with 0.1ºC resolution for temperature, 0.1 m/s resolution for wind speed and 0.1 % for relative humidity. Surface temperatures were registered using an infrared camera FLIR E4, with temperature resolution 0.15ºC. Minimal distance to surface of 0.5 m and Tª measurements range from -20ºC and 250ºC. The temperature profiles measured on the site showed the influence of solar exposure on the temperature variations along the day, as well as the influence of the heat irradiated by the building surfaces which had been exposed to the sun radiation and those influenced by the moist soft areas around the building. After the measurements were taken, the following simulations were conducted to evaluate the impact of the green roof on the microclimate: a. Standard roof: T4 building assuming a concrete tile roof with albedo 0.3. b. Green roof: T4 building assuming an extensive green roof with low LAD value (0.5)-Simple Sedum roof. c. Green roof: T4 building assuming an extensive green roof with high LAD value 1.5- Lucerne and grasses d. Green roof plus street level vegetation: T4 Building, LAD 1.5 (Lucerne), including the existing trees at street level. This scenario represents the current conditions of the building. The urban canopy wind was set as 1 m/s, the wind speed register at that level during the measurement campaign. This wind speed remained constant over the whole campaign. Under the above conditions, the results of the models show a moderate effect of green roofs on the surrounding microclimate ranging from 1ºC to 2ºC, but a larger contribution when combining it with vegetation at pedestrian level, where 4ºC temperature reductions are reached. Relative humidity remained constant. Measured temperatures and relative humidity were compared to model results, showing a close match in the profiles defined in both cases and the good capacity of ENVI met to capture the impact of the green roof in this analysis. The largest differences were registered in the areas close to the top areas of the facades which were more exposed to sun radiation and also near to the soil level. These differences might be caused by differences between the materials properties included in the model (which were limited by the data available in the software database) and those in the real building. An important observation derived from this study is the contribution of moist soil to the green roof effect on air temperatures. In the green roof scenario with surrounding trees, the effect of the moist soil contributes to raise the temperature reductions at 4.5ºC. A final analysis was conducted after extracting the hourly temperature profile in the street canyon influenced by the effect of green roofs and trees. An energy model was run on the building assuming it was a conventional enclosed building. Energy demand reductions were registered in the building reaching up to 14% reductions at the peak hour. The main conclusion of this study is the potential of the green roofs as a strategy for reducing air temperatures and energy consumption in the buildings, although this effect can be limited by the influence of high speed winds. This effect can be enhanced its combination with urban forests and even more if soft moist pavements are included in the urban canyon morphology, becoming a potential strategy for adapting urban ecosystems to the increasing temperature effect derived from climate change.
Resumo:
Carbon distribution in the stem of 2-year-old cork oak plants was studied by 14CO2 pulse labeling in late spring in order to trace the allocation of photoassimilates to tissue and biochemical stem components of cork oak. The fate of 14C photoassimilated carbon was followed during two periods: the first 72 h (short-term study) and the first 52 weeks (long-term study) after the 14CO2 photosynthetic assimilation. The results showed that 14C allocation to stem tissues was dependent on the time passed since photoassimilation and on the season of the year. In the first 3 h all 14C was found in the polar extractives. After 3 h, it started to be allocated to other stem fractions. In 1 day, 14C was allocated mostly to vascular cambium and, to a lesser extent, to primary phloem; no presence of 14C was recorded for the periderm. However, translocation of 14C to phellem was observed from 1 week after 14CO2 pulse labeling. The phellogen was not completely active in its entire circumference at labeling, unlike the vascular cambium; this was the tissue that accumulated most photoassimilated 14C at the earliest sampling. The fraction of leaf-assimilated 14C that was used by the stem peaked at 57% 1 week after 14CO2 plant exposure. The time lag between C photoassimilation and suberin accumulation was ∼8 h, but the most active period for suberin accumulation was between 3 and 7 days. Suberin, which represented only 1.77% of the stem weight, acted as a highly effective sink for the carbon photoassimilated in late spring since suberin specific radioactivity was much higher than for any other stem component as early as only 1 week after 14C plant labeling. This trend was maintained throughout the whole experiment. The examination of microautoradiographs taken over 1 year provided a new method for quantifying xylem growth. Using this approach it was found that there was more secondary xylem growth in late spring than in other times of the year, because the calculated average cell division time was much shorter.
Resumo:
The leaf cuticular ultrastructure of some plant species has been examined by transmission electron microscopy (TEM) in only few studies. Attending to the different cuticle layers and inner structure, plant cuticles have been grouped into six general morphological types. With the aim of critically examining the effect of cuticle isolation and preparation for TEM analysis on cuticular ultrastructure, adaxial leaf cuticles of blue-gum eucalypt, grey poplar, and European pear were assessed, following a membrane science approach. The embedding and staining protocols affected the ultrastructure of the cuticles analysed. The solubility parameter, surface tension, and contact angles with water of pure Spurr's and LR-White resins were within a similar range. Differences were however estimated for resin : solvent mixtures, since Spurr’s resin is combined with acetone and LR-White resin is mixed with ethanol. Given the composite hydrophilic and lipophilic nature of plant cuticles, the particular TEM tissue embedding and staining procedures employed may affect sample ultrastructure and the interpretation of the results in physicochemical and biological terms. It is concluded that tissue preparation procedures may be optimised to facilitate the observation of the micro- and nanostructure of cuticular layers and components with different degrees of polarity and hydrophobicity.
Resumo:
Plant trichomes play important protective functions and may have a major influence on leaf surface wettability. With the aim of gaining insight into trichome structure, composition and function in relation to water-plant surface interactions, we analyzed the adaxial and abaxial leaf surface of Quercus ilex L. (holm oak) as model. By measuring the leaf water potential 24 h after the deposition of water drops on to abaxial and adaxial surfaces, evidence for water penetration through the upper leaf side was gained in young and mature leaves. The structure and chemical composition of the abaxial (always present) and adaxial (occurring only in young leaves) trichomes were analyzed by various microscopic and analytical procedures. The adaxial surfaces were wettable and had a high degree of water drop adhesion in contrast to the highly unwettable and water repellent abaxial holm oak leaf sides. The surface free energy, polarity and solubility parameter decreased with leaf age, with generally higher values determined for the abaxial sides. All holm oak leaf trichomes were covered with a cuticle. The abaxial trichomes were composed of 8% soluble waxes, 49% cutin, and 43% polysaccharides. For the adaxial side, it is concluded that trichomes and the scars after trichome shedding contribute to water uptake, while the abaxial leaf side is highly hydrophobic due to its high degree of pubescence and different trichome structure, composition and density. Results are interpreted in terms of water-plant surface interactions, plant surface physical-chemistry, and plant ecophysiology.
Resumo:
Una investigación sobre la mejora de la contaminación del aire (CA) por medio de arbolado urbano se realizó en Madrid, una ciudad con casi 4 M de habitantes, 2,8 M de vehículos y casi 3 M de árboles de mantenimiento público. La mayoría de los árboles estaban en dos bosques periurbanos. Los 650.000 restantes era pies de alineación y parques. Los taxones estudiados fueron Platanus orientalis (97.205 árboles), Ulmus sp. (70.557), Pinus pinea (49.038), Aesculus hippocastanum (22.266), Cedrus sp. (13.678) y Quercus ilex (1.650), de calles y parques. Muestras foliares se analizaron en diferentes épocas del año, así como datos de contaminación por PM10 de 28 estaciones de medición de la contaminación durante 30 años, y también la intensidad del tráfico (IMD) en 2.660 calles. La acumulación de metales pesados (MP) sobre hojas y dentro de estas se estimó en relación con la CA y del suelo y la IMD del tráfico. La concentración media de Ba, Cd, Cr, Cu, Mn, Ni, Pb y Zn en suelo (materia seca) alcanzó: 489,5, 0,7, 49,4, 60,9, 460,9, 12,8, 155,9 y 190,3 mg kg-1 respectivamente. Los árboles urbanos, particularmente coníferas (debido a la mayor CA en invierno) contribuyen significativamente a mejorar la CA sobre todo en calles con alta IMD. La capacidad de las seis sp. para capturar partículas de polvo en su superficies foliares está relacionada con la IMD del tráfico y se estimó en 16,8 kg/año de MP tóxicos. Pb y Zn resultaron ser buenos marcadores antrópicos en la ciudad en relación con el tráfico, que fue la principal fuente de contaminación en los árboles y suelos de Madrid. Las especies de árboles variaron en función de su capacidad para capturar partículas (dependiendo de las propiedades de sus superficies foliares) y acumular los MP absorbidos de los suelos. Las concentraciones foliares de Pb y Zn estuvieron por encima de los límites establecidos en diferentes sitios de la ciudad. La microlocalización de Zn mediante microscópico mostró la translocación al xilema y floema. Se detectaron puntos de contaminación puntual de Cu and Cr en antiguos polígonos industriales y la distribución espacial de los MP en los suelos de Madrid mostró que en incluso en zonas interiores del El Retiro había ciertos niveles elevados de [Pb] en suelo, tal vez por el emplazamiento la Real Fábrica de Porcelana en la misma zona hace 200 años. Distintas áreas del centro de la ciudad también alcanzaron niveles altos de [Pb] en suelo. Según los resultados, el empleo de una combinación de Pinus pinea con un estrato intermedio de Ulmus sp. y Cedrus sp. puede ser la mejor recomendación como filtro verde eficiente. El efecto del ozono (O3) sobre el arbolado en Madrid fue también objeto de este estudio. A pesar de la reducción de precursores aplicada en muchos países industrializados, O3 sigue siendo la principal causa de CA en el hemisferio norte, con el aumento de [O3] de fondo. Las mayores [O3] se alcanzaron en regiones mediterráneas, donde el efecto sobre la vegetación natural es compensado por el xeromorfismo y la baja conductancia estomática en respuesta los episodios de sequía estival característicos de este clima. Durante una campaña de monitoreo, se identificaron daños abióticos en hojas de encina parecidos a los de O3 que estaban plantadas en una franja de césped con riego del centro de Madrid. Dada la poca evidencia disponible de los síntomas de O3 en frondosas perennifolias, se hizo un estudio que trató de 1) confirman el diagnóstico de daño de O3, 2) investigar el grado de los síntomas en encinas y 3) analizar los factores ambientales que contribuyeron a los daños por O3, en particular en lo relacionado con el riego. Se analizaron los marcadores macro y micromorfológicos de estrés por O3, utilizando las mencionadas encinas a modo de parcela experimental. Los síntomas consistieron en punteado intercostal del haz, que aumentó con la edad. Además de un punteado subyacente, donde las células superiores del mesófilo mostraron reacciones características de daños por O3. Las células próximas a las zonas dañadas, presentaron marcadores adicionales de estrés oxidativo. Estos marcadores morfológicos y micromorfológicos de estrés por O3 fueron similares a otras frondosas caducifolias con daños por O3. Sin embargo, en nuestro caso el punteado fue evidente con AOT40 de 21 ppm•h, asociada a riego. Análisis posteriores mostraron que los árboles con riego aumentaron su conductancia estomática, con aumento de senescencia, manteniéndose sin cambios sus características xeromórficas foliares. Estos hallazgos ponen de relieve el papel primordial de la disponibilidad de agua frente a las características xeromórficas a la hora de manifestarse los síntomas en las células por daños de O3 en encina. ABSTRACT Research about air pollution mitigation by urban trees was conducted in Madrid (Spain), a southern European city with almost 4 M inhabitants, 2.8 M daily vehicles and 3 M trees under public maintenance. Most trees were located in two urban forests, while 650'000 trees along urban streets and in parks. The urban taxa included Platanus orientalis (97'205 trees), Ulmus sp. (70’557), Pinus pinea (49'038), Aesculus hippocastanum (22’266), Cedrus sp. (13'678 and Quercus ilex (1'650) along streets and parks. Leave samples were analysed sequentially in different seasons, PM10 data from 28 air monitoring stations during 30 years and traffic density estimated from 2’660 streets. Heavy metal (HM) accumulation on the leaf surface and within leaves was estimated per tree related to air and soil pollution, and traffic intensity. Mean concentration of Ba, Cd, Cr, Cu, Mn, Ni, Pb and Zn in topsoil samples (dry mass) amounted in Madrid: 489.5, 0.7, 49.4, 60.9, 460.9, 12.8, 155.9 and 190.3 mg kg-1 respectively. Urban trees, particularly conifers (due to higher pollution in winter) contributed significantly to alleviate air pollution especially near to high ADT roads. The capacity of the six urban street trees species to capture air-born dust on the foliage surface as related to traffic intensity was estimated to 16.8 kg of noxious metals from exhausts per year. Pb and Zn pointed to be tracers of anthropic activity in the city with vehicle traffic as the main source of diffuse pollution on trees and soils. Tree species differed by their capacity to capture air-borne dust (by different leaf surface properties) and to allocate HM from soils. Pb and Zn concentrations in the foliage were above limits in different urban sites and microscopic Zn revelation showed translocation in xylem and phloem tissue. Punctual contamination in soils by Cu and Cr was identified in former industrial areas and spatial trace element mapping showed for central Retiro Park certain high values of [Pb] in soils even related to a Royal pottery 200 years ago. Different areas in the city centre also reached high levels [Pb] in soils. According to the results, a combination of Pinus pinea with understorey Ulmus sp. and Cedrus sp. layers can be recommended for the best air filter efficiency. The effects of ozone (O3) on trees in different areas of Madrid were also part of this study. Despite abatement programs of precursors implemented in many industrialized countries, ozone remained the main air pollutant throughout the northern hemisphere with background [O3] increasing. Some of the highest ozone concentrations were measured in regions with a Mediterranean climate but the effect on the natural vegetation is alleviated by low stomatal uptake and frequent leaf xeromorphy in response to summer drought episodes characteristic of this climate. During a bioindication survey, abiotic O3-like injury was identified in foliage. Trees were growing on an irrigated lawn strip in the centre of Madrid. Given the little structural evidence available for O3 symptoms in broadleaved evergreen species, a study was undertaken in 2007 with the following objectives 1) confirm the diagnosis, 2) investigate the extent of symptoms in holm oaks growing in Madrid and 3) analyse the environmental factors contributing to O3 injury, particularly, the site water supply. Therefore, macro- and micromorphological markers of O3 stress were analysed, using the aforementioned lawn strip as an intensive study site. Symptoms consisted of adaxial and intercostal stippling increasing with leaf age. Underlying stippling, cells in the upper mesophyll showed HR-like reactions typical of ozone stress. The surrounding cells showed further oxidative stress markers. These morphological and micromorphological markers of ozone stress were similar to those recorded in deciduous broadleaved species. However, stippling became obvious already at an AOT40 of 21 ppm•h and was primarily found at irrigated sites. Subsequent analyses showed that irrigated trees had their stomatal conductance increased and leaf life-span reduced whereas their leaf xeromorphy remained unchanged. These findings suggest a central role of water availability versus leaf xeromorphy for ozone symptom expression by cell injury in holm oak.
Resumo:
En las últimas dos décadas, los productores han plantado olivares en seto para lograr la mecanización de la poda y en especial de la cosecha, reducir los costes de mano de obra y permitir intervenciones de manejo rápidas y oportunas. Los olivares se desarrollaron en ausencia del conocimiento científico, sobre el diseño óptimo de la estructura de la copa, necesario para incrementar la producción y calidad del aceite. En contraste, con los árboles muy espaciados y distribuidos uniformemente de las plantaciones tradicionales, en el olivar en seto hay una marcada variabilidad espacial y temporal de la radiación disponible en función del diseño de la plantación. Así, conocer la respuesta fisiológica y productiva del olivo a la radiación resulta fundamental en el olivar en seto. La orientación de las filas y el ancho de calle son aspectos que se deciden en el diseño de las plantaciones en seto. Ambos aspectos modifican la radiación interceptada por la canopia y, por lo tanto, pueden incidir en la productividad y calidad del aceite. Una vez realizada la plantación no pueden ser modificados, y así las ventajas o desventajas permanecerán fijas durante toda la vida productiva del olivar. A pesar de esto, el impacto de la orientación de las filas y el ancho de calle han recibido poca atención en olivos y en la mayoría de los frutales conducidos en seto. Por todo ello, los objetivos principales de esta tesis fueron, (i) evaluar el efecto de la orientación del seto y del ancho de calle, sobre la productividad y calidad del aceite, (ii) evaluar un modelo que estime la radiación dentro de la canopia. Este modelo permitirá cuantificar las relaciones entre la radiación y los componentes del rendimiento y calidad del aceite de olivares en setos con un amplio rango de estructuras y (iii) conocer la variabilidad en las características de las hojas (morfológicas y fisiológicas) y de los tejidos del fruto (tamaño y composición) en diferentes posiciones de la copa de los setos. Para ello, se dispuso de 3 ensayos de olivar en seto (cv. Arbequina) implantados en 2008 en el municipio de La Puebla de Montalbán, Toledo. La primera cosecha fue en 2010 y a partir del 2012 los setos formaron una copa continua. A partir de ese año, los setos se mantuvieron mediante poda, con similar ancho (~1 m) y altura (~2,5 m), acordes a las dimensiones de la cosechadora vendimiadora. En los años 2012 y 2013 se estudió en profundidad la respuesta de las plantas de estos ensayos. En el ensayo 1, los setos fueron plantados con cuatro orientaciones de filas: N–S, NE–SO, NO–SE y E–O y el mismo ancho de calle (4 m). En los otros dos ensayos, los setos fueron plantados con tres anchos de calle (5,0, 4,0 y 2,5 m), y con filas orientadas N–S (ensayo 2) y E–O (ensayo 3). La respuesta de la orientación de las filas se evaluó a nivel de seto y de estratos del seto (alturas y caras), a través de mediciones del crecimiento de brotes, componentes reproductivos, características y temperatura del fruto, estado hídrico del suelo y de las plantas, fotosíntesis neta de las hojas y contenido de ácidos grasos. Los setos orientados NE–SO (2,7 t/ha) lograron la mayor producción de aceite, que fue significativamente más alta que la de los setos E–O (2,3 t/ha). La producción de aceite de los setos E–O no se diferenció estadísticamente de los setos N–S (2,5 t/ha). Las diferencias productivas entre orientaciones fueron explicadas por el número de frutos en cosecha, a su vez la variación en el número de frutos estuvo asociada al efecto de la orientación de las filas sobre el número de yemas desarrolladas y el porcentaje de inflorescencias fértiles. Las hojas en las caras iluminadas de los setos NE–SO y N–S presentaron mayor tasa fotosintética a la mañana (~10.0 h) que los setos E–O, en el año 2012, pero no en 2013. La orientación de las filas no tuvo un efecto significativo en el contenido de ácidos grasos de los aceites extraídos, esto ocurrió a pesar de variaciones en la temperatura interna de los frutos (3 °C) y de la radiación (40%) entre las distintas caras de los setos. La orientación del seto afectó significativamente al contenido relativo de agua del suelo, donde setos E–O presentaron valores más altos (12%) que setos N–S durante el verano y otoño. Sin embargo, el potencial hídrico de tallo fue similar entre orientaciones. En los ensayos 2 y 3, se evaluó el efecto que produce, a nivel de seto y de estratos (caras y alturas), reducir el ancho de calle de 5,0 a 4,0 y 2,5 m, en un seto orientado N–S y otro E–O, respectivamente. La relación entre altura/ancho de calle libre aumentó 0,6 a 0,8 y 1,6, al reducir 5,0, 4,0 y 2,5 m el ancho de calle, mientras la longitud de seto y el volumen de copa por hectárea incrementó 100% al reducir de 5,0 a 2,5 m, el ancho de calle. En los setos orientados N–S, la producción de aceite por ha acumulada en 4 campañas, incrementó significativamente un 52 %, al reducir de 5,0 a 2,5 m el ancho de calle. Los setos N–S con calle más estrecha (2,5 m) tuvieron un 19% menos frutos que los setos con calle más ancha (5,0 m) y a su vez el 60% de los mismos se localizaron los estratos altos de la canopia de los setos con calles estrecha en comparación al 40% en setos con calle de 5,0 m. En los estratos más bajos de los setos con calles de 2,5m hubo menor crecimiento de los brotes y los frutos tuvieron menor peso seco, contenido de aceite y madurez, que los frutos en los estratos bajos de los setos a 5,0 m. Los componentes del rendimiento y características de los frutos (agua y madurez) fueron similares entre la caras E y O, independientemente del ancho de calle. En los setos orientados E–O, la producción de aceite por ha acumulada en 4 campañas, no respondió significativamente al ancho de calle, debido a una disminución significativa en el número de frutos y producción de aceite por m de seto, al reducir de 5,0 a 2,5 m, el ancho de calle. En los setos orientados E–O, con calles de 5,0 m, los frutos presentaron similar peso seco, contenido de aceite y agua, en las caras S y N, sin embargo, cuando la calle fue reducida a 2,5, los frutos de la cara S fueron más pesado y maduros que en la cara N. Independientemente del ancho de calle y de la orientación del seto, el aceite presentó mayor contenido de ácidos palmitoleico, palmítico, esteárico y linoleico en los frutos del estrato más alto de la canopia disminuyendo hacia la base. En contraste, el contenido de ácido oleico aumentó desde el estrato más alto hacia la base de los setos. Las diferencias en el contenido de ácidos grasos entre la parte alta y baja de los setos, incrementó al reducir el ancho de calle en los setos N–S, pero no en los E-O. En conclusión, en olivares en seto, reducir el ancho de calle permite incrementar la producción de aceite, en setos orientados N–S, pero no en E–O. Un modelo que estima la cantidad y distribución de la radiación en toda la copa del seto, fue utilizado para estimar la radiación interceptada en distintos estratos del seto. El modelo requiere un valor del coeficiente de extinción (k) para estimar la transmisión de radiación a través de la copa, el cual fue obtenido experimentalmente (k=1,2). Utilizando los datos del ensayo 1, un único modelo lineal relacionó el peso seco y el rendimiento graso de setos con la radiación interceptada por los distintos estratos de setos con cuatro orientaciones de filas. La densidad de frutos fue también relacionada con la radiación, pero más débilmente. En los setos orientados N–S, plantados con tres anchos de calles, (ensayo 2) el contenido de ácidos palmitoleico y linoleico del aceite incrementó linealmente con el incremento de la radiación interceptada, mientras el contenido ácido oleico disminuyó linealmente con el incremento de la radiación. El contenido de ácidos grasos del aceite no estuvo relacionado con la radiación interceptada en setos orientados E–O (Ensayo 3). En los setos N–S y E–O, plantados con anchos de calle de 2,5 m, se estudiaron las interacciones entre la radiación y características de las hojas, número de fruto, tamaño y composición de los frutos a nivel de órgano, tejido y células. Independientemente de la orientación del seto, el área y el contenido de clorofila de las hojas incrementaron significativamente en los estratos más bajos de los setos. Mientras, las hojas de los estratos medios del seto presentaron mayor capacidad fotosintética que en los estratos bajos y alto de los setos. Los estratos del seto que interceptaron más radiación produjeron frutos con mayor tamaño y contenido de aceite en el mesocarpo, sin efectos sobre el tamaño y composición del endocarpo. A nivel celular, los frutos expuestos a mayor nivel de radiación desarrollaron en el mesocarpo células de mayor tamaño en comparación a frutos menos expuestos, mientras el número de células no fue afectado. Adicionalmente, el número y tamaño de las células estuvo relacionado con la composición del mesocarpo en términos de aceite, agua y peso seco menos aceite. Esta tesis, contribuye, desde una perspectiva integral del cultivo del olivo, a cuantificar el impacto de la orientación y ancho de calle sobre la producción y calidad del aceite en olivares conducidos en setos. El análisis y discusión de la relación entre la radiación y los componentes del rendimiento y calidad del aceite, puede ayudar a diseñar plantaciones en seto con dimensiones óptimas para la intercepción de la radiación. ABSTRACT In the last two decades, olive hedgerow system has been established by commercial growers to allow continuous mechanized pruning and especially harvest, reduce costs of manual labour and allow more rapid and timely management interventions. The adoption of hedgerow was done in the absence of adequate scientific knowledge of the impact of this orchard structure and associated mechanization on tree response, yield and quality, after centuries in low-density orchards and open-formed trees. The row orientation and width alley are fundamental aspects in the hedgerow design and have been scarcely studied in olive. Both aspects modify the radiation intercepted by the canopy, and consequently the productivity and oil quality, and once defined in orchard planting cannot be changed, so advantages and disadvantages remain fixed for the lifespan of the orchard. The main objectives of this thesis were to (i) evaluate the impact of the row orientation and width alley on productivity and oil quality by the measurements of profile of the determining processes of shoot growth, fruit temperature, yield components and fruit and oil characteristics on opposite sides of olive hedgerows. Additionally, the effect of row orientation on the plant water status was also evaluated; (ii) evaluate a mathematical model for estimating the radiation within the canopy and quantify the relationships between the radiation estimated and yield components and oil quality in olive hedgerows under wide range of structures and; (iii) determine the variability in the characteristics of the leaves (morphological and physiological) and fruit tissues (size and composition) in different positions of the hedgerows canopy. Three plots of olive hedgerows (cv. Arbequina) planted in 2008 in La Puebla de Montalbán, Toledo were evaluated during the 2012 and 2013 seasons. The hedgerows were maintained by lateral pruning and topping with the same width (1 m) and height (2.5 m) compatible with the intended harvester. In a plot (experiment 1), the hedgerows were planted with the same width alley (4 m) and four row orientations: N–S, NE–SW, NW–SE and E–W. Other two plots (Experiments 2 and 3) separated by approximately 100 m were planted with N–S and E–O oriented rows and three alley widths in each orientation: 5.0, 4.0 and 2.5 m. In the exp. 1, maximum fruit yield were achieved by NE–SW and NW–SW (15.7 t/ha). Of these, NE–SW achieved the highest oil yield (2.7 t/ha). There were no differences in fruit or oil yield between N–S (2.5 t oil/ha) and E–W (2.3 t oil/ha) orientations. Fruit number was the most important component to explain these differences, by previous influence on number of bud developed and percentage of fertile inflorescences. Fruit maturity and oil quality on both sides of the hedgerows were not affected by row orientation. This occurred despite significant variations in the internal fruit temperature, which was closely related to the irradiance received by the canopy and the time of day. Additionally, row orientation significantly affected the relative water content of the soil, where E–W oriented hedgerows showed consistently higher values than N–S during summer-autumn season. The stem water potential at midday, however, was similar between orientations, revealing possible lower water consumption of E–W than N–S oriented hedgerows. In the exp. 2, regardless of row orientation, reduction of row spacing from 5.0 to 4.0 and 2.5 m increases the ratio of canopy depth to free alley width (Al/An) from 0.6 to 0.8 and 1.6, respectively, and ads 25 and 100 % more hedgerow length per ha. In N–S oriented hedgerows, oil production per ha increased significantly by 14 and 52 % in 4.0 m and 2.5 m relative to 5.0 m row spacing, the effect being proportionally less than the increase in hedgerow length per ha. Hedgerows spaced 2.5 m with Al/An = 1.6 produced relatively fewer fruits per unit length than did wider spacings and were preferentially distributed in upper layers. Fruits located at the bottom of the canopy were smaller, with lower oil content and were less mature. In E–W oriented hedgerows, oil production per ha did not respond significantly to row spacing, despite the doubling of row length from the 5.0 to the 2.5 m row spacing. The explanation was found in fewer fruit per unit length of hedgerow and smaller oil content at 2.5 m than 5.0 m row spacing, averaged over the experimental period. In E–W hedgerows spaced at 5.0 m with Al/An = 0.6, the vertical profiles of fruit characteristics (mass, oil and water contents, and maturity) were similar between opposing sides, but at 4.0 m (Al/An= 0.8) and 2.5 m (Al/An=1.6) spacings, fruits on the S side were heavier and more mature than on N side. The oil extracted from fruits harvested at different heights of N–S and E–W oriented hedgerows showed higher palmitoleic, palmitic, stearic and linoleic contents at the canopy top decreasing toward base. The oleic content was reverse, increased from top to base. In N–S hedgerows, vertical gradients increased by reducing the alley width, but not in the E–W oriented hedgerows. The simulation of internal canopy irradiance was related in a single relationship (R2 = 0.63) to the vertical profiles of fruit weight and oil content of olive hedgerows with wide range of structures. The density of fruits was also associated with the irradiance but more weakly (R2 = 0.27), and revealed a more complex response involving changes in the vegetative structure by canopy management (topping) and the effect of radiation on the previous sequence that defines the number of fruits. The vertical profiles of oil quality traits were closely associated to canopy irradiance, but only when the N–S oriented hedgerows were considered. The contents of palmitoleic and linoleic acid in the oil increased linearly when intercepted irradiance increased from 9 to 19 mol PAR/m2. In contrast, oleic content decreased linearly in this irradiance range. Additionally, we advanced knowledge regarding the interactions among irradiance and leaf, fruit number, size and composition at organ-, tissue- and cellular- levels. The irradiance received at different positions in the canopy strongly affected the leaf area and chlorophyll content, and mesocarp size and composition (water and oil), without effects on endocarp size and composition. At the cellular level, light-exposed fruit developed larger mesocarp cells than shaded fruits, but cell number was not affected. Our results indicate that cell number and size are related to mesocarp composition in term of oil, water, and dry weight menus oil, although the specific manner in which they interact remains to be determined. This research contributes from an integral perspective of olive growing to quantify the impact of row orientation and width alley on productivity and oil quality in hedgerows systems. The analysis and discussion of the relationships between radiation and yield components and oil quality can help understand the impact of design olive hedgerows in general and in a wide range of environmental conditions.