5 resultados para holographic grating

em Universidad Politécnica de Madrid


Relevância:

30.00% 30.00%

Publicador:

Resumo:

A complete simulation of the transmission performance for Equalized Holographic ROADM (Reconfigurable Optical Add-Drop Multiplexer) designs is presented in this paper. These devices can address several wavelengths from the input to different output fibres, according to the holograms stored in a SLM (Spatial Light Modulator), where all the outputs are equalized in power. All combinations of the input wavelengths are possible at the different output fibres. To simulate the transmission performance of the EH-ROADM, a software program, from Optiwave, has been used. The correspondence between physical blocks of the device (grating, SLM, lens...) and those simulated in the program (filters, losses, splitters...) has been defined in order to obtain a close agreement between the theoretical transmission performance and the simulated one. To complete the review about Equalized Holographic ROADMs some guidelines about its design have been done.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent studies have dealt with the possibility of increasing light absorption by using the so-called electric field enhancement taking place within the grooves of metallic gratings. In order to evaluate the potential improvements derived from the absorption increase, we employ a simplified model to analyze the low-injection behaviour of a solar cell with a metallic grating back-reflector.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El equilibrio es una habilidad compleja esencial para la realización de cualquier tarea motriz y para la prevención de lesiones y caídas. La aparición de las pulseras holográficas, con supuestos beneficios entre los cuales se incluye la mejora del equilibrio, recibió la atención del público y los medios de comunicación por igual. Sin embargo, no hay evidencia científica de que los hologramas mejoren cualquier atributo físico. El objetivo de este estudio fue evaluar el efecto de las pulseras holográficas Power Balance® en el equilibrio. Siguiendo un método triple ciego, 25 estudiantes sanos y físicamente activos universitarios (14 mujeres, 11 hombres) fueron sometidos a la prueba de organización sensorial (SOT) en dos días separados mientras llevaban una pulsera con o sin hologramas (los ensayos se realizaron al azar en un orden contrabalanceado). El SOT proporciona detalles sobre el equilibrio total y la contribución relativa de los tres sistemas sensoriales principales (somatosensoriales, visuales y vestibulares) que intervienen en el equilibrio. Los resultados para el grupo como un todo revelaron que el uso de una pulsera holográfica no tiene ningún efecto significativo en cualquiera de estas variables. Sin embargo, cuando se analizaron los resultados de las mujeres de forma aislada, el uso de las pulseras holográficas se asoció con diferencias significativas en las puntuaciones de dos variables SOT: Equilibrio compuesto (86.5±3.7 con la pulsera holográfica en comparación con 85.5±4.5 sin ella; p?0.05) y la media general (93.5±2.0 en comparación con 92.8±2.4; p?0.05). Sin embargo, aunque a nivel estadístico estas diferencias fueron encontradas, la magnitud era tan pequeña que el equilibrio no se podría haber mejorado en ningún sentido práctico. En conclusión, las pulseras holográficas Power Balance® no ejercen ningún efecto significativo en el equilibrio en adultos jóvenes sanos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El presente trabajo de Tesis se ha centrado en el diseño, fabricación y caracterización de dispositivos basados en fibras de cristal fotónico infiltrado selectivamente con cristales líquidos, polímeros y una mezcla de ambos. Todos los dispositivos son sintonizables, y su área de aplicación se centra en comunicaciones ópticas y sensores. La manipulación y fusionado de fibras fotónicas, el llenado selectivo de determinadas cavidades y la alineación recíproca de fibras mantenedoras de polarización son tareas muy específicas y delicadas para las que se requieren protocolos muy estrictos. Previo a la fabricación de dispositivos ha sido necesaria por tanto una tarea de sistematización y creación de protocolos de fabricación. Una vez establecidos se ha procedido a la fabricación y caracterización de dispositivos. Los dispositivos fabricados se enumeran a continuación para posteriormente detallar una a una las singularidades de cada uno. • Interferómetros intermodales hechos a partir de una porción de fibra fotónica soldada entre dos fibras estándar, bien monomodo o PANDA (mantenedora de polarización). Estos interferómetros han sido sumergidos o bien llenados selectivamente con cristales líquidos para así sintonizar la señal interferométrica guiada a través de la fibra. • Infiltración de fibras fotónicas con cristales líquidos colestéricos con especial énfasis en la fase azul (blue phase) de estos materiales. Las moléculas de cristal líquido se autoalinean en volumen por lo que la infiltración de fibras fotónicas con estos cristales líquidos es muy interesante, pues es conocida la dificultad de alinear apropiadamente cristales líquidos dentro de cavidades micrométricas de las fibras fotónicas. • Grabación de redes holográficas de forma selectiva en las cavidades de una fibra fotónica. Estas redes holográficas, llamadas POLICRYPS (POlymer-LIquid CRYstal-Polymer Slices), son redes fabricadas a base de franjas de polímero y cristal líquido alineado perpendicularmente a dichas franjas. Las franjas son a su vez perpendiculares al eje de la fibra como lo puede ser una red de Bragg convencional. El cristal líquido, al estar alineado perpendicularmente a dichos franjas y paralelo al eje de la fibra, se puede conmutar aplicando un campo eléctrico externo, modificando así el índice efectivo de la red. Se puede fabricar por lo tanto una red de Bragg sintonizable en fibra, muy útil en comunicaciones ópticas. • Llenado selectivo de fibras fotónicas con polidimetilsiloxano (PDMS), un polímero de tipo silicona. Si se realiza un llenado selectivo asimétrico se puede inducir birrefringencia en la fibra. El índice de refracción del PDMS tiene una fuerte dependencia térmica, por lo que se puede sintonizar la birrefringencia de la fibra. • Estudio teórico de llenado selectivo de fibras fotónicas con PDMS dopado con nanopartículas de plata de 5, 40 y 80 nm. Estas nanopartículas poseen un pico de absorción en torno a los 450 nm debido a resonancias superficiales localizadas de plasmones (LSPR). La resonancia del plasmon tiene una fuerte dependencia con el índice de refracción del material colindante, y al ser éste PDMS, la variación de índice de refracción se ve amplificada, obteniendo una absorción sintonizable. Se ha propuesto la fabricación de polarizadores sintonizables usando esta técnica. Como ya se ha dicho, previamente a la fabricación ha sido necesaria la protocolización de diversos procedimientos de fabricación de alta complejidad, así como protocolizar el proceso de toma de medidas para optimizar los resultados. Los procedimientos que han requerido la formulación de protocolos específicos han sido los siguientes: • Llenado selectivo de cavidades en una fibra fotónica. Dichas fibras tienen generalmente un diámetro externo de 125 μm, y sus cavidades son de entre 5 y 10 μm de diámetro. Se han desarrollado tres técnicas diferentes para el llenado/bloqueado selectivo, pudiéndose combinar varios protocolos para la optimización del proceso. Las técnicas son las siguientes: o Llenado y bloqueado con un prepolímero. Dicho prepolímero, también llamado adhesivo óptico, está inicialmente en estado líquido y posee una cierta viscosidad. Las cavidades de la fibra fotónica que se desea llenar o bloquear poseen un diámetro diferente al resto, por lo que en el proceso de llenado aparecen dos frentes de llenado dependientes de su diámetro. A mayor diámetro, mayor velocidad de llenado. Polimerizando cuando existe dicha diferencia en los frentes se puede cortar por medio, obteniendo así una fibra parcialmente bloqueada. o Colapsamiento de las cavidades de menor diámetro mediante aplicación de calor. El calor producido por un arco voltaico de una soldadora de fibra estándar fusiona el material exterior de la fibra produciendo el colapsamiento de las cavidades de menor diámetro. En esta técnica también es necesaria una diferencia de diámetros en las cavidades de la fibra. o Bloqueo una a una de las cavidades de la fibra fotónica con adhesivo óptico. Este procedimiento es muy laborioso y requiere mucha precisión. Con este sistema se pueden bloquear las cavidades deseadas de una fibra sin importar su diámetro. • Alineación de una fuente de luz linealmente polarizada con una fibra mantenedora de polarización ya sea PANDA o fotónica. Así mismo también se han alineado entre sí fibras mantenedoras de polarización, para que sus ejes rápidos se fusionen paralelos y así el estado de polarización de la luz guiada se mantenga. • Sistematización de toma de medidas para caracterizar los interferómetros modales. Éstos son altamente sensibles a diversas variables por lo que el proceso de medida es complejo. Se deben aislar variables de forma estrictamente controlada. Aunque todos los dispositivos tienen en común el llenado selectivo de cavidades en una fibra fotónica cada dispositivo tiene sus peculiaridades, que van a ser explicadas a continuación. ABSTRACT The present Thesis has been centered in the design, fabrication and characterization of devices based on photonic crystal fibers selectively filled with liquid crystals, polymers and a mixture of both. All devices are tunable and their work field is optical communications and sensing The handling and splicing of photonic crystal fibers, the selective filling of their holes and the aligning of polarization maintaining fibers are very specific and delicate tasks for which very strict protocols are required. Before the fabrication of devices has therefore been necessary task systematization and creation of manufacturing protocols. Once established we have proceeded to the fabrication and characterization of devices. The fabricated devices are listed below and their peculiarities are detailed one by one: • Intermodal interferometers made with a portion of photonic crystal fiber spliced between two optical communication fiber pigtails, either single mode or PANDA (polarization-maintaining) fiber. These interferometers have been submerged or selectively filled with liquid crystals to tune the interferometric guided signal. • Infiltration of photonic fibers with cholesteric liquid crystals with special emphasis on their blue phase (blue phase). The liquid crystal molecules are self-aligning in volume so the infiltration of photonic fibers with these liquid crystals is very interesting. It is notoriously difficult to properly align liquid crystals within micron cavities such as photonic fibers. • Selectively recording of holographic gratings in the holes of photonic crystal fibers. These holographic gratings, called POLICRYPS (POlymer-LIquid CRYstal-Polymes Slices), are based on walls made of polymer and liquid crystal aligned perpendicular to them. These walls are perpendicular to the axis of the fiber as it can be a conventional Bragg grating. The liquid crystal is aligned perpendicular to the walls and parallel to the fiber axis, and can be switched by applying an external electric field and thus change the effective index of the grating. It is thus possible to manufacture a tunable Bragg grating fiber, useful in optical communications. •Asymmetrically selective filling of photonic crystal fibers with a silicone polymer like called polydimethylsiloxane (PDMS) to induce birefringence in the fiber. The refractive index of PDMS has temperature dependence, so that the birefringence of the fiber can be tuned. • Theoretical study of photonic crystal fibers selectively filled with PDMS doped with silver nanoparticles of 5, 40 and 80 nm. These nanoparticles have an absorption peak around 450 nm due to localized surface plasmon resonances (LSPR). Plasmon resonance has a strong dependence on the refractive index of the adjacent material, and as this is PDMS, the refractive index variation is amplified, obtaining a tunable absorption. Fabrication of tunable polarizers using this technique has been proposed. Before starting the fabrication, it has been necessary to optimize several very delicate procedures and different protocols have been designed. The most delicate procedures are as follows: • Selective filling of holes in a photonic crystal fiber. These fibers generally have an outer diameter of 125 μm, and their holes have a diameter around between 5 and 10 μm. It has been developed three different techniques for filling / selective blocking, and they can be combined for process optimization. The techniques are: o Filling and blocked with a prepolymer. This prepolymer also called optical adhesive is initially in liquid state and has a certain viscosity. The holes of the photonic crystal fiber that are desired to be filled or blocked should have a different diameter, so that in the filling process appear two different fronts depending on the hole diameter. The holes with larger diameter are filled faster. Then the adhesive is polymerized when there is such a difference on the front. A partially blocked fiber is obtained cutting between fronts. o Collapsing of holes of smaller diameter by application of heat. The heat produced by an arc of a standard fusion splicer fuses the outer fiber material producing the collapsing of the cavities of smaller diameter. In this technique also you need a difference of diameters in the fiber holes. o Blocking one by one the holes of photonic crystal fiber with optical adhesive. This procedure is very laborious and requires great precision. This system can block unwanted cavities regardless fiber diameter. • Aligning a linearly polarized light source with a polarization-maintaining fiber (either a PANDA fiber as a photonic crystal fiber). It is needed also an aligning between polarization-maintaining fibers, so that their fast axes parallel merge and that is state of polarization of light guided is maintained. • Systematization of taking measurements to characterize the modal interferometers. These are highly sensitive to several variables so the measurement process is very complicated. Variables must be fixed in a very controlled manner. Although all devices have the common characteristic of being selectively filled PCFs with some kind of material, each one has his own peculiarities, which are explained below.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Los sensores de fibra óptica son una tecnología que ha madurado en los últimos años, sin embargo, se requiere un mayor desarrollo de aplicaciones para materiales naturales como las rocas, que por ser agregados complejos pueden contener partículas minerales y fracturas de tamaño mucho mayor que las galgas eléctricas usadas tradicionalmente para medir deformaciones en las pruebas de laboratorio, ocasionando que los resultados obtenidos puedan ser no representativos. En este trabajo fueron diseñados, fabricados y probados sensores de deformación de gran área y forma curvada, usando redes de Bragg en fibra óptica (FBG) con el objetivo de obtener registros representativos en rocas que contienen minerales y estructuras de diversas composiciones, tamaños y direcciones. Se presenta el proceso de elaboración del transductor, su caracterización mecánica, su calibración y su evaluación en pruebas de compresión uniaxial en muestras de roca. Para verificar la eficiencia en la transmisión de la deformación de la roca al sensor una vez pegado, también fue realizado el análisis de la transferencia incluyendo los efectos del adhesivo, de la muestra y del transductor. Los resultados experimentales indican que el sensor desarrollado permite registro y transferencia de la deformación fiables, avance necesario para uso en rocas y otros materiales heterogénos, señalando una interesante perspectiva para aplicaciones sobre superficies irregulares, pues permite aumentar a voluntad el tamaño y forma del área de registro, posibilita también obtener mayor fiabilidad de resultados en muestras de pequeño tamaño y sugiere su conveniencia en obras, en las cuales los sistemas eléctricos tradicionales tienen limitaciones. ABSTRACT Optical fiber sensors are a technology that has matured in recent years, however, further development for rock applications is needed. Rocks contain mineral particles and features larger than electrical strain gauges traditionally used in laboratory tests, causing the results to be unrepresentative. In this work were designed, manufactured, and tested large area and curved shape strain gages, using fiber Bragg gratings in optical fiber (FBG) in order to obtain representative measurement on surface rocks samples containing minerals and structures of different compositions, sizes and directions. This reports presents the processes of manufacturing, mechanical characterization, calibration and evaluation under uniaxial compression tests on rock samples. To verify the efficiency of rock deformation transmitted to attached sensor, it was also performed the analysis of the strain transfer including the effects of the bonding, the sample and the transducer. The experimental results indicate that the developed sensor enables reliable measurements of the strain and its transmission from rock to sensor, appropriate for use in heterogeneous materials, pointing an interesting perspective for applications on irregular surfaces, allowing increasing at will the size and shape of the measurement area. This research suggests suitability of the optical strain gauge for real scale, where traditional electrical systems have demonstrated some limitations.