7 resultados para harmonic model
em Universidad Politécnica de Madrid
Resumo:
Seeding plasma-based softx-raylaser (SXRL) demonstrated diffraction-limited, fully coherent in space and in time beam but with energy not exceeding 1 μJ per pulse. Quasi-steady-state (QSS) plasmas demonstrated to be able to store high amount of energy and then amplify incoherent SXRL up to several mJ. Using 1D time-dependant Bloch–Maxwell model including amplification of noise, we demonstrated that femtosecond HHG cannot be efficiently amplified in QSS plasmas. However, using Chirped Pulse Amplification concept on HHG seed allows to extract most of the stored energy, reaching up to 5 mJ in fully coherent pulses that can be compressed down to 130 fs.
Resumo:
Canonical test cases for sloshing wave impact problems are pre-sented and discussed. In these cases the experimental setup has been simpli?ed seeking the highest feasible repeatability; a rectangular tank subjected to harmonic roll motion has been the tested con?guration. Both lateral and roof impacts have been studied, since both cases are relevant in sloshing assessment and show speci?c dynamics. An analysis of the impact pressure of the ?rst four impact events is provided in all cases. It has been found that not in all cases a Gaussian ?tting of each individual peak is feasible. The tests have been conducted with both water and oil in order to obtain high and moderate Reynolds number data; the latter may be useful as simpler test cases to assess the capabilities of CFD codes in simulating sloshing impacts. The re-peatability of impact pressure values increases dramatically when using oil. In addition, a study of the two-dimensionality of the problem using a tank con?guration that can be adjusted to 4 di?erent thicknesses has been carried out. Though the kinemat-ics of the free surface does not change signi cantly in some of the cases, the impact pressure values of the ?rst impact events changes substantially from the small to the large aspect ratios thus meaning that attention has to be paid to this issue when reference data is used for validation of 2D and 3D CFD codes.
Resumo:
The derivative nonlinear Schrödinger (DNLS) equation, describing propagation of circularly polarized Alfven waves of finite amplitude in a cold plasma, is truncated to explore the coherent, weakly nonlinear, cubic coupling of three waves near resonance, one wave being linearly unstable and the other waves damped. In a reduced three-wave model (equal damping of daughter waves, three-dimensional flow for two wave amplitudes and one relative phase), no matter how small the growth rate of the unstable wave there exists a parametric domain with the flow exhibiting chaotic dynamics that is absent for zero growth-rate. This hard transition in phase-space behavior occurs for left-hand (LH) polarized waves, paralelling the known fact that only LH time-harmonic solutions of the DNLS equation are modulationally unstable.
Resumo:
The derivative nonlinear Schrödinger (DNLS) equation, describing propagation of circularly polarized Alfven waves of finite amplitude in a cold plasma, is truncated to explore the coherent, weakly nonlinear coupling of three waves near resonance, one wave being linearly unstable and the other waves damped. No matter how small the growth rate of the unstable wave, the four-dimensional flow for the three wave amplitudes and a relative phase, with both resistive damping and linear Landau damping, exhibits chaotic relaxation oscillations that are absent for zero growth-rate. This hard transition in phase-space behavior occurs for left-hand (LH) polarized waves, paralleling the known fact that only LH time-harmonic solutions of the DNLS equation are modulationally unstable. The parameter domain developing chaos is much broader than the corresponding domain in a reduced 3-wave model that assumes equal dampings of the daughter waves
Resumo:
Crowd induced dynamic loading in large structures, such as gymnasiums or stadiums, is usually modelled as a series of harmonic loads which are defined in terms of their Fourier coefficients. Different values of these Fourier coefficients that were obtained from full scale measurements can be found in codes. Recently, an alternative has been proposed, based on random generation of load time histories that take into account phase lags among individuals inside the crowd. Generally the testing is performed on platforms or structures that can be considered rigid because their natural frequencies are higher than the excitation frequencies associated with crowd loading. In this paper we shall present the testing done on a structure designed to be a gymnasium, which has natural frequencies within that range. In this test the gym slab was instrumented with acceleration sensors and different people jumped on a force plate installed on the floor. Test results have been compared with predictions based on the two abovementioned load modelling alternatives and a new methodology for modelling jumping loads has been proposed in order to reduce the difference between experimental and numerical results at high frequency range.
Resumo:
The calibration results of one anemometer equipped with several rotors, varying their size, were analyzed. In each case, the 30-pulses pert turn output signal of the anemometer was studied using Fourier series decomposition and correlated with the anemometer factor (i.e., the anemometer transfer function). Also, a 3-cup analytical model was correlated to the data resulting from the wind tunnel measurements. Results indicate good correlation between the post-processed output signal and the working condition of the cup anemometer. This correlation was also reflected in the results from the proposed analytical model. With the present work the possibility of remotely checking cup anemometer status, indicating the presence of anomalies and, therefore, a decrease on the wind sensor reliability is revealed.
Resumo:
A specific numerical procedure for the analysis of arbitrary nonprismatic folded plate structures is presented. An elastic model is studied and compared with a harmonic solution for a prismatic structure. An extension to the plastic analysis is developed, and the influence of the structural geometry and loading pattern is analyzed. Nonprismatic practical cases, with arbitrary geometry and loading are shown, as well in the elastic range as in the plastic one. Finally, a dynamic formulation is outlined