34 resultados para fire safety design

em Universidad Politécnica de Madrid


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Between 2003 and 2007 an urban network or road tunnels with a total constructed tubes length of 45 km was built in the city of Madrid. This amazing engineering work, known as "Calle 30 Project" counted with different kinds of tunnel typologies and ventilation systems. Due to the length of the tunnels and the impact of the work itself, the tunnels were endowed with a great variety of installations to provide the maximum levels of safety both for users and the infrastructure includieng, in some parts of the tunnel, fixed fire fighting system based on water mist. Whithin this framework a large-scale programme of fire tests was planned to study different aspects related to fire safety in the tunnels including the phenomena of the interaction between ventilation and extinguishing system. In addition, these large scale fire tests allowed fire brigades of the city of Madrid an opportunity to define operational procedures for specific fire fighting in tunnels and evaluate the possibilities of fixed fire fighting systems. The tests were carried out in the Center of Experimentation "San pedro of Anes" which includes a 600 m tunnel with a removable false ceiling for reproducing different ceiling heights and ventilation conditions (transverse and longitudinal ones). Interesting conclusions on the interaction of ventilation and water mist systems were obtained but also on other aspects including performance of water mist system in terms of reduction of gas temperatures or visibility conditions. This paper presents a description of the test's programme carried out and some previous results obtained.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Between 2003 and 2007 an urban network of road tunnels with a total constructed tubes length of 45 km was built in the city of Madrid. This amazing engineering work, known as “Calle30 Project” counted with different kinds of tunnel typologies and ventilation systems. Due to the length of the tunnels and the impact of the work itself, the tunnels were endowed with a great variety of installations to provide the maximum levels of safety both for users and the infrastructure including,in some parts of the tunnel, fixed fire fighting system based on water mist. Within this framework a large-scale campaign of fire tests were planned to study different aspects related to fire safety in the tunnels including the phenomena of the interaction between ventilation and extinction system. In addition, this large scale fire tests allowed fire brigades of the city of Madrid an opportunity to define operational procedures for specific fire fighting in tunnels and evaluate the possibilities of fixed fire fighting systems. The tests were carried out in the Center of Experimentation "San Pedro of Anes" which counts with a 600 m tunnel with a removable false ceiling for reproducing different ceiling heights and ventilation conditions (transverse and longitudinal ones). Interesting conclusions on the interaction of ventilation and water mist systems were obtained but also on other aspects including performance of water mist system in terms of reduction of gas temperatures or visibility conditions. This paper presents a description of the test’s campaign carried out and some previous results obtained.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The objective of the present study is to develop fully renewable and environmentally benign techniques for improving the fire safety of flexible polyurethane foams (PUFs). A multilayered coating made from cationic chitosan (CS) and anionic alginate (AL) was deposited on PUFs through layer-by-layer assembly. This coating system exhibits a slight influence on the thermal stability of PUF, but significantly improves the char formation during combustion. Cone calorimetry reveals that 10 CS-AL bilayers (only 5.7% of the foams weight) lead to a 66% and 11% reduction in peak heat release rate and total heat release, respectively, compared with those of the uncoated control. The notable decreased fire hazards of PUF are attributed to the CS-AL coatings being beneficial to form an insulating protective layer on the surface of burning materials that inhibits the oxygen and heat permeation and slows down the flammable gases in the vapor phase, and thereby improves the flame resistance. This water-based, environmentally benign natural coating will stimulate further efforts in improving fire safety for a variety of polymer substrates.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

La movilidad geográfica es, sin lugar a dudas, uno de los aspectos sociales que más se ha potenciado en los últimos años tanto en el ámbito nacional como mundial. Debido a las grandes dificultades orográficas que se dan en la Unión Europea es preciso desarrollar complejos proyectos donde los túneles son un elemento clave. Paradójicamente, los recientes incendios acaecidos en túneles en todo el mundo han generado dudas acerca de la necesidad de incrementar el número y, sobre todo, la longitud de túneles pero han supuesto un aliciente para profundizar en el estudio de los criterios de seguridad adoptados hasta ese momento. En concreto, dentro del conjunto de instalaciones disponibles en los túneles de carretera el sistema de ventilación juega un papel fundamental por su relación con los criterios de seguridad. En este sentido, el mayor conocimiento de los fenómenos que intervienen en los procesos de producción y evolución de los humos permiten definir criterios de dimensionamiento y funcionamiento de la ventilación más sofisticados. Sin embargo para poder asegurar la calidad del conjunto es preciso, por una parte, partir de una correcta definición a nivel de Proyecto de la solución constructiva la defmición de criterios de actuación precisos a adoptar en caso de incendio y por último el establecimiento de procedimientos de supervisión globales. En el artículo propuesto se abordan desde una perspectiva global las distintas etapas de definición y control que deben realizarse para garantizar el correcto funcionamiento de la instalación, se profundiza en los modelos numéricos empleados para el dimensionamiento y se recogen aspectos de la experiencia resultante de ensayos in-situ realizados. Como ejemplo se presentan resultados para distintos túneles de carreteras en España.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Durante las últimas décadas, científicos e ingenieros han desarrollado un gran esfuerzo en la comprensión por los temas relacionados con el impacto entre cuerpos sólidos. La complejidad del desarrollo teórico y el desconocimiento acerca del comportamiento real de los materiales en problemas de carga rápida ha limitado tradicionalmente los problemas de impacto a geometrías muy concretas de los cuerpos incidentes, sin embargo, la evolución de la velocidad en los ordenadores y las mejoras en los métodos y elementos de instrumentación han aumentado el alcance y la fiabilidad de los datos experimentales y consecuentemente han sido un nuevo impulso en el estudio en este campo. El enfoque actual de las normativas basado en el análisis de riesgos permite la posibilidad de abordar la seguridad estructural a través de modelos explícitos, en los que las variables básicas del problema se definen de forma estadística y la seguridad se fija en función de probabilidades de fallo frente a los estados límite. Los métodos de fiabilidad estructural deben ser capaces de analizar toda la información estadística; es habitual el uso del método de Montecarlo, superficie de respuesta, estimaciones puntuales, nivel 11, etc. y en todos ellos es fundamental el conocimiento de un procedimiento determinista que permita evaluar el grado de cumplimiento de los estados límite. En ésta presentación se entra directamente en los modelos deterministas de cálculo, obviando el estudio estadístico más propio de un capítulo destinado a la fiabilidad estructural. Para ello, se han recogido unas ideas acerca de cómo se aborda el problema del impacto de una forma tradicional, se comienza con los choques elásticos e inelásticos de cuerpos rígidos. Los cuerpos rígidos dan paso a cuerpos elásticos donde la colisión genera una onda que recorre el cuerpo a una velocidad finita que se refleja en los contornos generando una vibración y en consecuencia una pérdida de energía en el choque. Posteriormente se abordará el impacto con materiales plásticos donde parte de la energía se transforma en la deformación permanente. Las explosiones pueden ser tratadas de forma análoga al impacto, ya que poseen la misma característica de cargas rápidas y son consideradas solicitaciones accidentales. La diferencia fundamental se centra en que los impactos requieren la existencia de dos cuerpos mientras que las explosiones sólo requieren un receptor y es el medio transmisor, generalmente el aire, quien transmite la solicitación mediante una onda de presión. En este artículo se comentan diferentes aspectos de la naturaleza de la solicitación y de su efecto sobre las estructuras.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

An analysis of the structure of flame balls encountered under microgravity conditions, which are stable due to radiant energy losses from H₂O, is carried out for fuel-lean hydrogen-air mixtures. It is seen that, because of radiation losses, in stable flame balls the maximum flame temperature remains close to the crossover temperature, at which the rate of the branching step H + O₂ -> OH + O equals that of the recombination step H + O₂ + M -> HO₂ + M. Under those conditions, all chemical intermediates have very small concentrations and follow the steady-state approximation, while the main species react according to the overall step 2H₂ + O₂-> 2H₂O; so that a one-step chemical-kinetic description, recently derived by asymptotic analysis for near-limit fuel-lean deflagrations, can be used with excellent accuracy to describe the whole branch of stable flame balls. Besides molecular diffusion in a binary-diffusion approximation, Soret diffusion is included, since this exerts a nonnegligible effect to extend the flammability range. When the large value of the activation energy of the overall reaction is taken into account, the leading-order analysis in the reaction-sheet approximation is seen to determine the flame ball radius as that required for radiant heat losses to remove enough of the heat released by chemical reaction at the flame to keep the flame temperature at a value close to crossover. The results are relevant to burning velocities at lean equivalent ratios and may influence fire-safety issues associated with hydrogen utilization.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

The design, construction and operation of the tunnels of M-30, the major ring road in the city of Madrid (Spain), represent a very interesting project in wich a wide variety of situations -geometrical, topographical, etc.- had to be covered, in variable conditions of traffic. For that reasons, the M-30 project is a remarkable technical challenge, which, after its completion, turned into an international reference. From the "design for safety" perspective, a holistic approach has been used to deal with new technologies, integration of systems and development of the procedures to reach the maximum level. However, one of the primary goals has been to achieve reasonable homogeneity characteristics which can permit operate a netword of tunels as one only infraestructure. In the case of the ventilation system the mentioned goals have implied innovative solutions and coordination efforts of great interest. Consequently, this paper describes the principal ideas underlying the conceptual solution developed focusing on the principal peculiarities of the project.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

The main objective of ventilation systems in tunnels is to reach the highest possible safety level both in service and fire situation; being the fire one, the most relevant when designing the system. When designing a longitudinal ventilation system, the methodology to evaluate the capacity of the system is similar both in service and fire situation, with the exception of the chimney effect and the phenomena of thermal transfer which is responsible or the changes in the density of the air. When facing the dimensioning task for longitudinal ventilated tunnels, although similar methodologies are used in different countries, specific hypothesis (aerodynamic, thermal properties, traffic) even if discussed in the literature or current practice, are not usually detailed in the regulations or recommendations. The aim of this paper is to propose a probabilistic approach to the problem which would allow the designer, and the tunnel owner, to understand the uncertainty and sensibility adopted in the results and, eventually, identify possible ways of optimizing the ventilation solution to be adopted.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This work is based on the prototype High Engineering Test Reactor (HTTR) of the Japan Agency of Energy Atomic (JAEA). Its objective is to describe an adequate deterministic model to be used in the assessment of its design safety margins via damage domains. The concept of damage domain is defined and it is shown its relevance in the ongoing effort to apply dynamic risk assessment methods and tools based on the Theory of Stimulated Dynamics (TSD). To illustrate, we present results of an abnormal control rod (CR) withdrawal during subcritical condition and its comparison with results obtained by JAEA. No attempt is made yet to actually assess the detailed scenarios, rather to show how the approach may handle events of its kind

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A probabilistic safety assessment (PSA) is being developed for a steam-methane reforming hydrogenproduction plant linked to a high-temperature gas-cooled nuclear reactor (HTGR). This work is based on the Japan Atomic Energy Research Institute's (JAERI) High Temperature Engineering Test Reactor (HTTR) prototype in Japan. The objective of this paper is to show how the PSA can be used for improving the design of the coupled plants. A simplified HAZOP study was performed to identify initiating events, based on existing studies. The results of the PSA show that the average frequency of an accident at this complex that could affect the population is 7 × 10−8 year−1 which is divided into the various end states. The dominant sequences are those that result in a methane explosion and occur with a frequency of 6.5 × 10−8 year−1, while the other sequences are much less frequent. The health risk presents itself if there are people in the vicinity who could be affected by the explosion. This analysis also demonstrates that an accident in one of the plants has little effect on the other. This is true given the design base distance between the plants, the fact that the reactor is underground, as well as other safety characteristics of the HTGR.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Since the Three Mile Island accident, an important focus of pressurized water reactor (PWR) transient analyses has been a small-break loss-of-coolant accident (SBLOCA). In 2002, the discovery of thinning of the vessel head wall at the Davis Besse nuclear power plant reactor indicated the possibility of an SBLOCA in the upper head of the reactor vessel as a result of circumferential cracking of a control rod drive mechanism penetration nozzle - which has cast even greater importance on the study of SBLOCAs. Several experimental tests have been performed at the Large Scale Test Facility to simulate the behavior of a PWR during an upper-head SBLOCA. The last of these tests, Organisation for Economic Co-operation and Development Nuclear Energy Agency Rig of Safety Assessment (OECD/NEA ROSA) Test 6.1, was performed in 2005. This test was simulated with the TRACE 5.0 code, and good agreement with the experimental results was obtained. Additionally, a broad analysis of an upper-head SBLOCA with high-pressure safety injection failed in a Westinghouse PWR was performed taking into account different accident management actions and conditions in order to check their suitability. This issue has been analyzed also in the framework of the OECD/NEA ROSA project and the Code Applications and Maintenance Program (CAMP). The main conclusion is that the current emergency operating procedures for Westinghouse reactor design are adequate for these kinds of sequences, and they do not need to be modified.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The construction of a Gothic vault implied the solution of several technical challenges. The literature on Gothic vault construction is quite large and its growth continues steadily. The main challenge of any structure is that, during and after construction, it must be "safe", that is, it must not collapse. Indeed, it must be amply safe, able to support different loads for long periods of time. Masonry architecture has shown its structural safety for centuries or millennia. The Pantheon of Rome stands today after almost 2,000 years without having needed any structural reinforcement (of course, the survival of any building implies continuous maintenance) . Hagia Sophia in Istanbul, finished in the 6th century AD, has withstood not only the dead loads but also many severe earthquakes . Finally, the Gothic cathedrals, with their appearance of weakness, are• more than a half millennium old. The question arises of what the source of this amazing strength is and how the illiterate master masons were able to design such daring and safe structures . This question is usually evaded in manuals of Gothic architecture. This is quite surprising, the structure being a fundamental part of Gothic buildings. The present article aims to give such an explanation, which has been studied in detail elsewhere. In the first part, the Gothic design methods "V ill be discussed. In the second part, the validity of these methods wi11 be verified within the frame of the modern theory of masonry structures . References have been reduced to a minimum to make the text simpler and more direct.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, vehicle-track interaction for a new slab track design, conceived to reduce noise and vibration levels has been analyzed, assessing the derailment risk for trains running on curved track when encountering a broken rail. Two different types of rail fastening systems with different elasticities have been analysed and compared. Numerical methods were used in order to simulate the dynamic behaviour of the train-track interaction. Multibody system (MBS) modelling techniques were combined with techniques based on the finite element method (FEM). MBS modelling was used for modelling the vehicle and FEM for simulating the elastic track. The simulation model was validated by comparing simulated results to experimental data obtained in field testing. During the simulations various safety indices, characteristic of derailment risk, were analysed. The simulations realised at the maximum running velocity of 110 km/h showed a similar behaviour for several track types. When reducing the running speed, the safety indices worsened for both cases. Although the worst behaviour was observed for the track with a greater elasticity, in none of the simulations did a derailment occur when running over the broken rail.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Railway bridges have specific requirements related to safety, which often are critical aspects of design. In this paper the main phenomena are reviewed, namely vertical dynamic effects for impact effect of moving loads and resonance in high-speed, service limit states which affect the safety of running traffic, and lateral dynamic effects.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A Probabilistic Safety Assessment (PSA) is being developed for a steam-methane reforming hydrogen production plant linked to a High-Temperature Gas Cooled Nuclear Reactor (HTGR). This work is based on the Japan Atomic Energy Research Institute’s (JAERI) High Temperature Test Reactor (HTTR) prototype in Japan. This study has two major objectives: calculate the risk to onsite and offsite individuals, and calculate the frequency of different types of damage to the complex. A simplified HAZOP study was performed to identify initiating events, based on existing studies. The initiating events presented here are methane pipe break, helium pipe break, and PPWC heat exchanger pipe break. Generic data was used for the fault tree analysis and the initiating event frequency. Saphire was used for the PSA analysis. The results show that the average frequency of an accident at this complex is 2.5E-06, which is divided into the various end states. The dominant sequences result in graphite oxidation which does not pose a health risk to the population. The dominant sequences that could affect the population are those that result in a methane explosion and occur 6.6E-8/year, while the other sequences are much less frequent. The health risk presents itself if there are people in the vicinity who could be affected by the explosion. This analysis also demonstrates that an accident in one of the plants has little effect on the other. This is true given the design base distance between the plants, the fact that the reactor is underground, as well as other safety characteristics of the HTGR. Sensitivity studies are being performed in order to determine where additional and improved data is needed.