7 resultados para epicanthic folds

em Universidad Politécnica de Madrid


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper deals with the development and achievements of structures conformed by concrete folded plates. It explores the origins of its analysis and calculation and shows an overview of the main folded plate structures between 1950 and 1970. Great number of technical articles and publications on folded structures appeared in these two decades, to quickly decline shortly after. At least in a symbolic sense, their end can be certified by a memorable and monographic IASS symposium held in 1970 on such structures. More than four decades after the last of the large-scale structures of this type was erected, a review of achievements and possible causes of decadence seems to be pertinent, furthermore considering the growing and renewed interest in the geometry of folds and facets of the last years.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BioMet®Tools is a set of software applications developed for the biometrical characterization of voice in different fields as voice quality evaluation in laryngology, speech therapy and rehabilitation, education of the singing voice, forensic voice analysis in court, emotional detection in voice, secure access to facilities and services, etc. Initially it was conceived as plain research code to estimate the glottal source from voice and obtain the biomechanical parameters of the vocal folds from the spectral density of the estimate. This code grew to what is now the Glottex®Engine package (G®E). Further demands from users in medical and forensic fields instantiated the development of different Graphic User Interfaces (GUI’s) to encapsulate user interaction with the G®E. This required the personalized design of different GUI’s handling the same G®E. In this way development costs and time could be saved. The development model is described in detail leading to commercial production and distribution. Study cases from its application to the field of laryngology and speech therapy are given and discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new design for a photovoltaic concentrator, the most recent advance based on the Kohler concept, is presented. The system is mirror-based, and with geometry that guaranties a maximum sunlight collection area (without shadows, like those caused by secondary stages or receivers and heat-sinks in other mirror-based systems). Designed for a concentration of 1000x, this off axis system combines both good acceptance angle and good irradiance uniformity on the solar cell. The advanced performance features (concentration-acceptance products ?CAP- about 0.73 and affordable peak and average irradiances) are achieved through the combination of four reflective folds combined with four refractive surfaces, all of them free-form, performing Köhler integration 2 . In Köhler devices, the irradiance uniformity is not achieved through additional optical stages (TIR prisms), thus no complex/expensive elements to manufacture are required. The rim angle and geometry are such that the secondary stage and receivers are hidden below the primary mirrors, so maximum collection is assured. The entire system was designed to allow loose assembly/alignment tolerances (through high acceptance angle) and to be manufactured using already well-developed methods for mass production, with high potential for low cost. The optical surfaces for Köhler integration, although with a quite different optical behavior, have approximately the same dimensions and can be manufactured with the same techniques as the more traditional secondary optical elements used for concentration (typically plastic injection molding or glass molding).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La medicina ha evolucionado de forma que las imágenes digitales tienen un papel de gran relevancia para llevar a cabo el diagnóstico de enfermedades. Son muchos y de diversa naturaleza los problemas que pueden presentar el aparato fonador. Un paso previo para la caracterización de imágenes digitales de la laringe es la segmentación de las cuerdas vocales. Hasta el momento se han desarrollado algoritmos que permiten la segmentación de la glotis. El presente proyecto pretende avanzar un paso más en el estudio, procurando asimismo la segmentación de las cuerdas vocales. Para ello, es necesario aprovechar la información de color que ofrecen las imágenes, pues es lo que va a determinar la diferencia entre una región y otra de la imagen. En este proyecto se ha desarrollado un novedoso método de segmentación de imágenes en color estroboscópicas de la laringe basado en el crecimiento de regiones a partir de píxeles-semilla. Debido a los problemas que presentan las imágenes obtenidas por la técnica de la estroboscopia, para conseguir óptimos resultados de la segmentación es necesario someter a las imágenes a un preprocesado, que consiste en la eliminación de altos brillos y aplicación de un filtro de difusión anisotrópica. Tras el preprocesado, comienza el crecimiento de la región a partir de unas semillas que se obtienen previamente. La condición de inclusión de un píxel en la región se basa en un parámetro de tolerancia que se determina de forma adaptativa. Este parámetro comienza teniendo un valor muy bajo y va aumentando de forma recursiva hasta alcanzar una condición de parada. Esta condición se basa en el análisis de la distribución estadística de los píxeles dentro de la región que va creciendo. La última fase del proyecto consiste en la realización de las pruebas necesarias para verificar el funcionamiento del sistema diseñado, obteniéndose buenos resultados en la segmentación de la glotis y resultados esperanzadores para seguir mejorando el sistema para la segmentación de las cuerdas vocales. ABSTRACT Medicine has evolved so that digital images have a very important role to perform disease diagnosis. There are wide variety of problems that can present the vocal apparatus. A preliminary step for characterization of digital images of the larynx is the segmentation of the vocal folds. To date, some algorithms that allow the segmentation of the glottis have been developed. This project aims to go one step further in the study, also seeking the segmentation of the vocal folds. To do this, we must use the color information offered by images, since this is what will determine the difference between different regions in a picture. In this project a novel method of larynx color images segmentation based on region growing from a pixel seed is developed. Due to the problems of the images obtained by the technique of stroboscopy, to achieve optimal results of the segmentation is necessary a preprocessing of the images, which involves the removal of high brightness and applying an anisotropic diffusion filter. After this preprocessing, the growth of the region from previously obtained seeds starts. The condition for inclusion of a pixel in the region is based on a tolerance parameter, which is adaptively determined. It initially has a low value and this is recursively increased until a stop condition is reached. This condition is based on the analysis of the statistical distribution of the pixels within the grown region. The last phase of the project involves the necessary tests to verify the proper working of the designed system, obtaining very good results in the segmentation of the glottis and encouraging results to keep improving the system for the segmentation of the vocal folds.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La óptica anidólica es una rama de la óptica cuyo desarrollo comenzó a mediados de la década de 1960. Este relativamente nuevo campo de la óptica se centra en la transferencia eficiente de la luz, algo necesario en muchas aplicaciones, entre las que destacamos los concentradores solares y los sistemas de iluminación. Las soluciones de la óptica clásica a los problemas de la transferencia de energía de la luz sólo son adecuadas cuando los rayos de luz son paraxiales. La condición paraxial no se cumple en la mayoría de las aplicaciones para concentración e iluminación. Esta tesis contiene varios diseños free-form (aquellos que no presentan ninguna simetría, ni de rotación ni lineal) cuyas aplicaciones van destinadas a estos dos campos. El término nonimaging viene del hecho de que estos sistemas ópticos no necesitan formar una imagen del objeto, aunque no formar la imagen no es una condición necesaria. Otra palabra que se utiliza a veces en lugar de nonimaging es la palabra anidólico, viene del griego "an+eidolon" y tiene el mismo significado. La mayoría de los sistemas ópticos diseñados para aplicaciones anidólicas no presentan ninguna simetría, es decir, son free-form (anamórficos). Los sistemas ópticos free-form están siendo especialmente relevantes durante los últimos años gracias al desarrollo de las herramientas para su fabricación como máquinas de moldeo por inyección y el mecanizado multieje. Sin embargo, solo recientemente se han desarrollado técnicas de diseño anidólicas capaces de cumplir con estos grados de libertad. En aplicaciones de iluminación el método SMS3D permite diseñar dos superficies free-form para controlar las fuentes de luz extensas. En los casos en que se requiere una elevada asimetría de la fuente, el objeto o las restricciones volumétricos, las superficies free-form permiten obtener soluciones de mayor eficiencia, o disponer de menos elementos en comparación con las soluciones de simetría de rotación, dado que las superficies free-form tienen más grados de libertad y pueden realizar múltiples funciones debido a su naturaleza anamórfica. Los concentradores anidólicos son muy adecuados para la captación de energía solar, ya que el objetivo no es la reproducción de una imagen exacta del sol, sino sencillamente la captura de su energía. En este momento, el campo de la concentración fotovoltaica (CPV) tiende hacia sistemas de alta concentración con el fin de compensar el gasto de las células solares multi-unión (MJ) utilizadas como receptores, reduciendo su área. El interés en el uso de células MJ radica en su alta eficiencia de conversión. Para obtener sistemas competitivos en aplicaciones terrestres se recurre a sistemas fotovoltaicos de alta concentración (HCPV), con factores de concentración geométrica por encima de 500x. Estos sistemas se componen de dos (o más) elementos ópticos (espejos y/o lentes). En los sistemas presentados a lo largo de este trabajo se presentan ejemplos de concentradores HCPV con elementos reflexivos como etapa primaria, así como concentradores con elementos refractivos (lente de Fresnel). Con la necesidad de aumentar la eficiencia de los sistemas HCPV reales y con el fin de proporcionar la división más eficiente del espectro solar, células conteniendo cuatro o más uniones (con un potencial de alcanzar eficiencias de más del 45% a una concentración de cientos de soles) se exploran hoy en día. En esta tesis se presenta una de las posibles arquitecturas de división del espectro (spectrum-splitting en la literatura anglosajona) que utilizan células de concentración comercial. Otro campo de aplicación de la óptica nonimaging es la iluminación, donde es necesario proporcionar un patrón de distribución de la iluminación específico. La iluminación de estado sólido (SSL), basada en la electroluminiscencia de materiales semiconductores, está proporcionando fuentes de luz para aplicaciones de iluminación general. En la última década, los diodos emisores de luz (LED) de alto brillo han comenzado a reemplazar a las fuentes de luz convencionales debido a la superioridad en la calidad de la luz emitida, elevado tiempo de vida, compacidad y ahorro de energía. Los colimadores utilizados con LEDs deben cumplir con requisitos tales como tener una alta eficiencia, un alto control del haz de luz, una mezcla de color espacial y una gran compacidad. Presentamos un colimador de luz free-form con microestructuras capaz de conseguir buena colimación y buena mezcla de colores con una fuente de LED RGGB. Una buena mezcla de luz es importante no sólo para simplificar el diseño óptico de la luminaria sino también para evitar hacer binning de los chips. La mezcla de luz óptica puede reducir los costes al evitar la modulación por ancho de pulso y otras soluciones electrónicas patentadas para regulación y ajuste de color. Esta tesis consta de cuatro capítulos. Los capítulos que contienen la obra original de esta tesis son precedidos por un capítulo introductorio donde se presentan los conceptos y definiciones básicas de la óptica geométrica y en el cual se engloba la óptica nonimaging. Contiene principios de la óptica no formadora de imagen junto con la descripción de sus problemas y métodos de diseño. Asimismo se describe el método de Superficies Múltiples Simultáneas (SMS), que destaca por su versatilidad y capacidad de controlar varios haces de rayos. Adicionalmente también se describe la integración Köhler y sus aplicaciones en el campo de la energía fotovoltaica. La concentración fotovoltaica y la iluminación de estado sólido son introducidas junto con la revisión de su estado actual. El Segundo y Tercer Capítulo contienen diseños ópticos avanzados con aplicación en la concentración solar principalmente, mientras que el Cuarto Capítulo describe el colimador free-form con surcos que presenta buena mezcla de colores para aplicaciones de iluminación. El Segundo Capítulo describe dos concentradores ópticos HCPV diseñados con el método SMS en tres dimensiones (SMS3D) que llevan a cabo integración Köhler en dos direcciones con el fin de proporcionar una distribución de irradiancia uniforme libre de aberraciones cromáticas sobre la célula solar. Uno de los diseños es el concentrador XXR free-form diseñado con el método SMS3D, donde el espejo primario (X) y la lente secundaria (R) se dividen en cuatro sectores simétricos y llevan a cabo la integración Köhler (proporcionando cuatro unidades del array Köhler), mientras que el espejo intermedio (X) presenta simetría rotacional. Otro concentrador HCPV presentado es el Fresnel-RXI (FRXI) con una lente de Fresnel funcionando como elemento primario (POE) y una lente RXI como elemento óptico secundario (SOE), que presenta configuración 4-fold con el fin de realizar la integración Köhler. Las lentes RXI son dispositivos nonimaging conocidos, pero su aplicación como elemento secundario es novedosa. Los concentradores XXR y FRXI Köhler son ejemplos académicos de muy alta concentración (más de 2,000x, mientras que los sistemas convencionales hoy en día no suelen llegar a 1,000x) preparados para las células solares N-unión (con N>3), que probablemente requerirán una mayor concentración y alta uniformidad espectral de irradiancia con el fin de obtener sistemas CPV terrestres eficientes y rentables. Ambos concentradores están diseñados maximizando funciones de mérito como la eficiencia óptica, el producto concentración-aceptancia (CAP) y la uniformidad de irradiancia sobre la célula libre de la aberración cromática (integración Köhler). El Tercer Capítulo presenta una arquitectura para la división del espectro solar basada en un módulo HCPV con alta concentración (500x) y ángulo de aceptancia alto (>1º) que tiene por objeto reducir ambas fuentes de pérdidas de las células triple unión (3J) comerciales: el uso eficiente del espectro solar y la luz reflejada de los contactos metálicos y de la superficie de semiconductor. El módulo para la división del espectro utiliza el espectro solar más eficiente debido a la combinación de una alta eficiencia de una célula de concentración 3J (GaInP/GaInAs/Ge) y una de contacto posterior (BPC) de concentración de silicio (Si), así como la técnica de confinamiento externo para la recuperación de la luz reflejada por la célula 3J con el fin de ser reabsorbida por la célula. En la arquitectura propuesta, la célula 3J opera con su ganancia de corriente optimizada (concentración geométrica de 500x), mientras que la célula de silicio trabaja cerca de su óptimo también (135x). El módulo de spectrum-splitting consta de una lente de Fresnel plana como POE y un concentrador RXI free-form como SOE con un filtro paso-banda integrado en él. Tanto POE como SOE realizan la integración Köhler para producir homogeneización de luz sobre la célula. El filtro paso banda envía los fotones IR en la banda 900-1,150nm a la célula de silicio. Hay varios aspectos prácticos de la arquitectura del módulo presentado que ayudan a reducir la complejidad de los sistemas spectrum-splitting (el filtro y el secundario forman una sola pieza sólida, ambas células son coplanarias simplificándose el cableado y la disipación de calor, etc.). Prototipos prueba-de-concepto han sido ensamblados y probados a fin de demostrar la fabricabilidad del filtro y su rendimiento cuando se combina con la técnica de reciclaje de luz externa. Los resultados obtenidos se ajustan bastante bien a los modelos y a las simulaciones e invitan al desarrollo de una versión más compleja de este prototipo en el futuro. Dos colimadores sólidos con surcos free-form se presentan en el Cuarto Capítulo. Ambos diseños ópticos están diseñados originalmente usando el método SMS3D. La segunda superficie ópticamente activa está diseñada a posteriori como una superficie con surcos. El diseño inicial de dos espejos (XX) está diseñado como prueba de concepto. En segundo lugar, el diseño RXI free-form es comparable con los colimadores RXI existentes. Se trata de un diseño muy compacto y eficiente que proporciona una muy buena mezcla de colores cuando funciona con LEDs RGB fuera del eje óptico como en los RGB LEDs convencionales. Estos dos diseños son dispositivos free-form diseñados con la intención de mejorar las propiedades de mezcla de colores de los dispositivos no aplanáticos RXI con simetría de revolución y la eficiencia de los aplanáticos, logrando una buena colimación y una buena mezcla de colores. La capacidad de mezcla de colores del dispositivo no-aplanático mejora añadiendo características de un aplanático a su homólogo simétrico sin pérdida de eficiencia. En el caso del diseño basado en RXI, su gran ventaja consiste en su menor coste de fabricación ya que el proceso de metalización puede evitarse. Aunque algunos de los componentes presentan formas muy complejas, los costes de fabricación son relativamente insensibles a la complejidad del molde, especialmente en el caso de la producción en masa (tales como inyección de plástico), ya que el coste del molde se reparte entre todas las piezas fabricadas. Por último, las últimas dos secciones son las conclusiones y futuras líneas de investigación. ABSTRACT Nonimaging optics is a branch of optics whose development began in the mid-1960s. This rather new field of optics focuses on the efficient light transfer necessary in many applications, among which we highlight solar concentrators and illumination systems. The classical optics solutions to the problems of light energy transfer are only appropriate when the light rays are paraxial. The paraxial condition is not met in most applications for the concentration and illumination. This thesis explores several free-form designs (with neither rotational nor linear symmetry) whose applications are intended to cover the above mentioned areas and more. The term nonimaging comes from the fact that these optical systems do not need to form an image of the object, although it is not a necessary condition not to form an image. Another word sometimes used instead of nonimaging is anidolic, and it comes from the Greek “an+eidolon” and has the same meaning. Most of the optical systems designed for nonimaging applications are without any symmetry, i.e. free-form. Free-form optical systems become especially relevant lately with the evolution of free-form tooling (injection molding machines, multi-axis machining techniques, etc.). Nevertheless, only recently there are nonimaging design techniques that are able to meet these degrees of freedom. In illumination applications, the SMS3D method allows designing two free-form surfaces to control very well extended sources. In cases when source, target or volumetric constrains have very asymmetric requirements free-form surfaces are offering solutions with higher efficiency or with fewer elements in comparison with rotationally symmetric solutions, as free-forms have more degrees of freedom and they can perform multiple functions due to their free-form nature. Anidolic concentrators are well suited for the collection of solar energy, because the goal is not the reproduction of an exact image of the sun, but instead the collection of its energy. At this time, Concentration Photovoltaics (CPV) field is turning to high concentration systems in order to compensate the expense of multi-junction (MJ) solar cells used as receivers by reducing its area. Interest in the use of MJ cells lies in their very high conversion efficiency. High Concentration Photovoltaic systems (HCPV) with geometric concentration of more than 500x are required in order to have competitive systems in terrestrial applications. These systems comprise two (or more) optical elements, mirrors and/or lenses. Systems presented in this thesis encompass both main types of HCPV architectures: concentrators with primary reflective element and concentrators with primary refractive element (Fresnel lens). Demand for the efficiency increase of the actual HCPV systems as well as feasible more efficient partitioning of the solar spectrum, leads to exploration of four or more junction solar cells or submodules. They have a potential of reaching over 45% efficiency at concentration of hundreds of suns. One possible architectures of spectrum splitting module using commercial concentration cells is presented in this thesis. Another field of application of nonimaging optics is illumination, where a specific illuminance distribution pattern is required. The Solid State Lighting (SSL) based on semiconductor electroluminescence provides light sources for general illumination applications. In the last decade high-brightness Light Emitting Diodes (LEDs) started replacing conventional light sources due to their superior output light quality, unsurpassed lifetime, compactness and energy savings. Collimators used with LEDs have to meet requirements like high efficiency, high beam control, color and position mixing, as well as a high compactness. We present a free-form collimator with microstructures that performs good collimation and good color mixing with RGGB LED source. Good light mixing is important not only for simplifying luminaire optical design but also for avoiding die binning. Optical light mixing may reduce costs by avoiding pulse-width modulation and other patented electronic solutions for dimming and color tuning. This thesis comprises four chapters. Chapters containing the original work of this thesis are preceded by the introductory chapter that addresses basic concepts and definitions of geometrical optics on which nonimaging is developed. It contains fundamentals of nonimaging optics together with the description of its design problems, principles and methods, and with the Simultaneous Multiple Surface (SMS) method standing out for its versatility and ability to control several bundles of rays. Köhler integration and its applications in the field of photovoltaics are described as well. CPV and SSL fields are introduced together with the review on their background and their current status. Chapter 2 and Chapter 3 contain advanced optical designs with primarily application in solar concentration; meanwhile Chapter 4 portrays the free-form V-groove collimator with good color mixing property for illumination application. Chapter 2 describes two HCPV optical concentrators designed with the SMS method in three dimensions (SMS3D). Both concentrators represent Köhler integrator arrays that provide uniform irradiance distribution free from chromatic aberrations on the solar cell. One of the systems is the XXR free-form concentrator designed with the SMS3D method. The primary mirror (X) of this concentrator and secondary lens (R) are divided in four symmetric sectors (folds) that perform Köhler integration; meanwhile the intermediate mirror (X) is rotationally symmetric. Second HCPV concentrator is the Fresnel-RXI (FRXI) with flat Fresnel lens as the Primary Optical Element (POE) and an RXI lens as the Secondary Optical Element (SOE). This architecture manifests 4-fold configuration for performing Köhler integration (4 array units), as well. The RXI lenses are well-known nonimaging devices, but their application as SOE is novel. Both XXR and FRXI Köhler HCPV concentrators are academic examples of very high concentration (more than 2,000x meanwhile conventional systems nowadays have up to 1,000x) prepared for the near future N-junction (N>3) solar cells. In order to have efficient and cost-effective terrestrial CPV systems, those cells will probably require higher concentrations and high spectral irradiance uniformity. Both concentrators are designed by maximizing merit functions: the optical efficiency, concentration-acceptance angle (CAP) and cell-irradiance uniformity free from chromatic aberrations (Köhler integration). Chapter 3 presents the spectrum splitting architecture based on a HCPV module with high concentration (500x) and high acceptance angle (>1º). This module aims to reduce both sources of losses of the actual commercial triple-junction (3J) solar cells with more efficient use of the solar spectrum and with recovering the light reflected from the 3J cells’ grid lines and semiconductor surface. The solar spectrum is used more efficiently due to the combination of a high efficiency 3J concentration cell (GaInP/GaInAs/Ge) and external Back-Point-Contact (BPC) concentration silicon (Si) cell. By employing external confinement techniques, the 3J cell’s reflections are recovered in order to be re-absorbed by the cell. In the proposed concentrator architecture, the 3J cell operates at its optimized current gain (at geometrical concentration of 500x), while the Si cell works near its optimum, as well (135x). The spectrum splitting module consists of a flat Fresnel lens (as the POE), and a free-form RXI-type concentrator with a band-pass filter embedded in it (as the SOE), both POE and SOE performing Köhler integration to produce light homogenization. The band-pass filter sends the IR photons in the 900-1,150nm band to the Si cell. There are several practical aspects of presented module architecture that help reducing the added complexity of the beam splitting systems: the filter and secondary are forming a single solid piece, both cells are coplanar so the heat management and wiring is simplified, etc. Two proof-of-concept prototypes are assembled and tested in order to prove filter manufacturability and performance, as well as the potential of external light recycling technique. Obtained measurement results agree quite well with models and simulations, and show an opened path to manufacturing of the Fresnel RXI-type secondary concentrator with spectrum splitting strategy. Two free-form solid V-groove collimators are presented in Chapter 4. Both free-form collimators are originally designed with the SMS3D method. The second mirrored optically active surface is converted in a grooved surface a posteriori. Initial two mirror (XX) design is presented as a proof-of-concept. Second, RXI free-form design is comparable with existing RXI collimators as it is a highly compact and a highly efficient design. It performs very good color mixing of the RGGB LED sources placed off-axis like in conventional RGB LEDs. Collimators described here improve color mixing property of the prior art rotationally symmetric no-aplanatic RXI devices, and the efficiency of the aplanatic ones, accomplishing both good collimation and good color mixing. Free-form V-groove collimators enhance the no-aplanatic device's blending capabilities by adding aplanatic features to its symmetric counterpart with no loss in efficiency. Big advantage of the RXI design is its potentially lower manufacturing cost, since the process of metallization may be avoided. Although some components are very complicated for shaping, the manufacturing costs are relatively insensitive to the complexity of the mold especially in the case of mass production (such as plastic injection), as the cost of the mold is spread in many parts. Finally, last two sections are conclusions and future lines of investigation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BioMet®Phon is a software application developed for the characterization of voice in voice quality evaluation. Initially it was conceived as plain research code to estimate the glottal source from voice and obtain the biomechanical parameters of the vocal folds from the spectral density of the estimate. This code grew to what is now the Glottex®Engine package (G®E). Further demands from users in laryngology and speech therapy fields instantiated the development of a specific Graphic User Interface (GUI’s) to encapsulate user interaction with the G®E. This gave place to BioMet®Phon, an application which extracts the glottal source from voice and offers a complete parameterization of this signal, including distortion, cepstral, spectral, biomechanical, time domain, contact and tremor parameters. The semantic capabilities of biomechanical parameters are discussed. Study cases from its application to the field of laryngology and speech therapy are given and discussed. Validation results in voice pathology detection are also presented. Applications to laryngology, speech therapy, and monitoring neurological deterioration in the elder are proposed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Las patologías de la voz se han transformado en los últimos tiempos en una problemática social con cierto calado. La contaminación de las ciudades, hábitos como el de fumar, el uso de aparatos de aire acondicionado, etcétera, contribuyen a ello. Esto alcanza más relevancia en profesionales que utilizan su voz de manera frecuente, como, por ejemplo, locutores, cantantes, profesores o teleoperadores. Por todo ello resultan de especial interés las técnicas de ayuda al diagnóstico que son capaces de extraer conclusiones clínicas a partir de una muestra de la voz grabada con un micrófono, frente a otras invasivas que implican la exploración utilizando laringoscopios, fibroscopios o videoendoscopios, técnicas en cualquier caso mucho más molestas para los pacientes al exigir la introducción parcial del instrumental citado por la garganta, en actuaciones consideradas de tipo quirúrgico. Dentro de aquellas técnicas se ha avanzado mucho en un período de tiempo relativamente corto. En lo que se refiere al diagnóstico de patologías, hemos pasado en los últimos quince años de trabajar principalmente con parámetros extraídos de la señal de voz –tanto en el dominio del tiempo como en el de la frecuencia– y con escalas elaboradas con valoraciones subjetivas realizadas por expertos a hacerlo también con parámetros procedentes de estimaciones de la fuente glótica. La importancia de utilizar la fuente glótica reside, a grandes rasgos, en que se trata de una señal vinculada directamente al estado de la estructura laríngea del locutor y también en que está generalmente menos influida por el tracto vocal que la señal de voz. Es conocido que el tracto vocal guarda más relación con el mensaje hablado, y su presencia dificulta el proceso de detección de patología vocal. Estas estimaciones de la fuente glótica han sido obtenidas a través de técnicas de filtrado inverso desarrolladas por nuestro grupo de investigación. Hemos conseguido, además, profundizar en la naturaleza de la señal glótica: somos capaces de descomponerla y relacionarla con parámetros biomecánicos de los propios pliegues vocales, obteniendo estimaciones de elementos como la masa, la pérdida de energía o la elasticidad del cuerpo y de la cubierta del pliegue, entre otros. De las componentes de la fuente glótica surgen también los denominados parámetros biométricos, relacionados con la forma de la señal, que constituyen por sí mismos una firma biométrica del individuo. También trabajaremos con parámetros temporales, relacionados con las diferentes etapas que se observan dentro de la señal glótica durante un ciclo de fonación. Por último, consideraremos parámetros clásicos de perturbación y energía de la señal. En definitiva, contamos ahora con una considerable cantidad de parámetros glóticos que conforman una base estadística multidimensional, destinada a ser capaz de discriminar personas con voces patológicas o disfónicas de aquellas que no presentan patología en la voz o con voces sanas o normofónicas. Esta tesis doctoral se ocupa de varias cuestiones: en primer lugar, es necesario analizar cuidadosamente estos nuevos parámetros, por lo que ofreceremos una completa descripción estadística de los mismos. También estudiaremos cuestiones como la distribución de los parámetros atendiendo a criterios como el de normalidad estadística de los mismos, ocupándonos especialmente de la diferencia entre las distribuciones que presentan sujetos sanos y sujetos con patología vocal. Para todo ello emplearemos diferentes técnicas estadísticas: generación de elementos y diagramas descriptivos, pruebas de normalidad y diversos contrastes de hipótesis, tanto paramétricos como no paramétricos, que considerarán la diferencia entre los grupos de personas sanas y los grupos de personas con alguna patología relacionada con la voz. Además, nos interesa encontrar relaciones estadísticas entre los parámetros, de cara a eliminar posibles redundancias presentes en el modelo, a reducir la dimensionalidad del problema y a establecer un criterio de importancia relativa en los parámetros en cuanto a su capacidad discriminante para el criterio patológico/sano. Para ello se aplicarán técnicas estadísticas como la Correlación Lineal Bivariada y el Análisis Factorial basado en Componentes Principales. Por último, utilizaremos la conocida técnica de clasificación Análisis Discriminante, aplicada a diferentes combinaciones de parámetros y de factores, para determinar cuáles de ellas son las que ofrecen tasas de acierto más prometedoras. Para llevar a cabo la experimentación se ha utilizado una base de datos equilibrada y robusta formada por doscientos sujetos, cien de ellos pertenecientes al género femenino y los restantes cien al género masculino, con una proporción también equilibrada entre los sujetos que presentan patología vocal y aquellos que no la presentan. Una de las aplicaciones informáticas diseñada para llevar a cabo la recogida de muestras también es presentada en esta tesis. Los distintos estudios estadísticos realizados nos permitirán identificar aquellos parámetros que tienen una mayor contribución a la hora de detectar la presencia de patología vocal. Alguno de los estudios, además, nos permitirá presentar una ordenación de los parámetros en base a su importancia para realizar la detección. Por otra parte, también concluiremos que en ocasiones es conveniente realizar una reducción de la dimensionalidad de los parámetros para mejorar las tasas de detección. Por fin, las propias tasas de detección constituyen quizá la conclusión más importante del trabajo. Todos los análisis presentes en el trabajo serán realizados para cada uno de los dos géneros, de acuerdo con diversos estudios previos que demuestran que los géneros masculino y femenino deben tratarse de forma independiente debido a las diferencias orgánicas observadas entre ambos. Sin embargo, en lo referente a la detección de patología vocal contemplaremos también la posibilidad de trabajar con la base de datos unificada, comprobando que las tasas de acierto son también elevadas. Abstract Voice pathologies have become recently in a social problem that has reached a certain concern. Pollution in cities, smoking habits, air conditioning, etc. contributes to it. This problem is more relevant for professionals who use their voice frequently: speakers, singers, teachers, actors, telemarketers, etc. Therefore techniques that are capable of drawing conclusions from a sample of the recorded voice are of particular interest for the diagnosis as opposed to other invasive ones, involving exploration by laryngoscopes, fiber scopes or video endoscopes, which are techniques much less comfortable for patients. Voice quality analysis has come a long way in a relatively short period of time. In regard to the diagnosis of diseases, we have gone in the last fifteen years from working primarily with parameters extracted from the voice signal (both in time and frequency domains) and with scales drawn from subjective assessments by experts to produce more accurate evaluations with estimates derived from the glottal source. The importance of using the glottal source resides broadly in that this signal is linked to the state of the speaker's laryngeal structure. Unlike the voice signal (phonated speech) the glottal source, if conveniently reconstructed using adaptive lattices, may be less influenced by the vocal tract. As it is well known the vocal tract is related to the articulation of the spoken message and its influence complicates the process of voice pathology detection, unlike when using the reconstructed glottal source, where vocal tract influence has been almost completely removed. The estimates of the glottal source have been obtained through inverse filtering techniques developed by our research group. We have also deepened into the nature of the glottal signal, dissecting it and relating it to the biomechanical parameters of the vocal folds, obtaining several estimates of items such as mass, loss or elasticity of cover and body of the vocal fold, among others. From the components of the glottal source also arise the so-called biometric parameters, related to the shape of the signal, which are themselves a biometric signature of the individual. We will also work with temporal parameters related to the different stages that are observed in the glottal signal during a cycle of phonation. Finally, we will take into consideration classical perturbation and energy parameters. In short, we have now a considerable amount of glottal parameters in a multidimensional statistical basis, designed to be able to discriminate people with pathologic or dysphonic voices from those who do not show pathology. This thesis addresses several issues: first, a careful analysis of these new parameters is required, so we will offer a complete statistical description of them. We will also discuss issues such as distribution of the parameters, considering criteria such as their statistical normality. We will take special care in the analysis of the difference between distributions from healthy subjects and the distributions from pathological subjects. To reach these goals we will use different statistical techniques such as: generation of descriptive items and diagramas, tests for normality and hypothesis testing, both parametric and nonparametric. These latter techniques consider the difference between the groups of healthy subjects and groups of people with an illness related to voice. In addition, we are interested in finding statistical relationships between parameters. There are various reasons behind that: eliminate possible redundancies in the model, reduce the dimensionality of the problem and establish a criterion of relative importance in the parameters. The latter reason will be done in terms of discriminatory power for the criterion pathological/healthy. To this end, statistical techniques such as Bivariate Linear Correlation and Factor Analysis based on Principal Components will be applied. Finally, we will use the well-known technique of Discriminant Analysis classification applied to different combinations of parameters and factors to determine which of these combinations offers more promising success rates. To perform the experiments we have used a balanced and robust database, consisting of two hundred speakers, one hundred of them males and one hundred females. We have also used a well-balanced proportion where subjects with vocal pathology as well as subjects who don´t have a vocal pathology are equally represented. A computer application designed to carry out the collection of samples is also presented in this thesis. The different statistical analyses performed will allow us to determine which parameters contribute in a more decisive way in the detection of vocal pathology. Therefore, some of the analyses will even allow us to present a ranking of the parameters based on their importance for the detection of vocal pathology. On the other hand, we will also conclude that it is sometimes desirable to perform a dimensionality reduction in order to improve the detection rates. Finally, detection rates themselves are perhaps the most important conclusion of the work. All the analyses presented in this work have been performed for each of the two genders in agreement with previous studies showing that male and female genders should be treated independently, due to the observed functional differences between them. However, with regard to the detection of vocal pathology we will consider the possibility of working with the unified database, ensuring that the success rates obtained are also high.