Resumo:

This paper provides some results on the potential to minimize environmental impacts in residential buildings life cycle, through façade design strategies, analyzing also their impact on costs from a lifecycle perspective. On one hand, it assesses the environmental damage produced by the materials of the building envelope, and on the other, the benefits they offer in terms of habitability and liveability in the use phase. The analysis includes several design parameters used both for rehabilitation of existing facades, as for new facades, trying to cover various determinants and proposing project alternatives. With this study we intended to contribute to address the energy challenges for the coming years, trying also to propose pathways for innovative solutions for the building envelope.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Concentrating Solar Power (CSP) plants typically incorporate one or various auxiliary boilers operating in parallel to the solar field to facilitate start up operations, provide system stability, avoid freezing of heat transfer fluid (HTF) and increase generation capacity. The environmental performance of these plants is highly influenced by the energy input and the type of auxiliary fuel, which in most cases is natural gas (NG). Replacing the NG with biogas or biomethane (BM) in commercial CSP installations is being considered as a means to produce electricity that is fully renewable and free from fossil inputs. Despite their renewable nature, the use of these biofuels also generates environmental impacts that need to be adequately identified and quantified. This paper investigates the environmental performance of a commercial wet-cooled parabolic trough 50 MWe CSP plant in Spain operating according to two strategies: solar-only, with minimum technically viable energy non-solar contribution; and hybrid operation, where 12 % of the electricity derives from auxiliary fuels (as permitted by Spanish legislation). The analysis was based on standard Life Cycle Assessment (LCA) methodology (ISO 14040-14040). The technical viability and the environmental profile of operating the CSP plant with different auxiliary fuels was evaluated, including: NG; biogas from an adjacent plant; and BM withdrawn from the gas network. The effect of using different substrates (biowaste, sewage sludge, grass and a mix of biowaste with animal manure) for the production of the biofuels was also investigated. The results showed that NG is responsible for most of the environmental damage associated with the operation of the plant in hybrid mode. Replacing NG with biogas resulted in a significant improvement of the environmental performance of the installation, primarily due to reduced impact in the following categories: natural land transformation, depletion of fossil resources, and climate change. However, despite the renewable nature of the biofuels, other environmental categories like human toxicity, eutrophication, acidification and marine ecotoxicity scored higher when using biogas and BM.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Water is a vital resource, but also a critical limiting factor for economic and social development in many parts of the world. The recent rapid growth in human population and water use for social and economic development is increasing the pressure on water resources and the environment, as well as leading to growing conflicts among competing water use sectors (agriculture, urban, tourism, industry) and regions (Gleick et al., 2009; World Bank, 2006). In Spain, as in many other arid and semi-arid regions affected by drought and wide climate variability, irrigated agriculture is responsible for most consumptive water use and plays an important role in sustaining rural livelihoods (Varela-Ortega, 2007). Historically, the evolution of irrigation has been based on publicly-funded irrigation development plans that promoted economic growth and improved the socio-economic conditions of rural farmers in agrarian Spain, but increased environmental damage and led to excessive and inefficient exploitation of water resources (Garrido and Llamas, 2010; Varela-Ortega et al., 2010). Currently, water policies in Spain focus on rehabilitating and improving the efficiency of irrigation systems, and are moving from technocratic towards integrated water management strategies driven by the European Union (EU) Water Framework Directive (WFD).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

El refuerzo de estructuras existentes mediante el encolado exterior de láminas de polímeros reforzados con fibras (FRP) se ha convertido en la aplicación más común de los materiales compuestos avanzados en construcción. Estos materiales presentan muchas ventajas frente a los materiales convencionales (sin corrosión, ligeros, de fácil aplicación, etc.). Pero a pesar de las numerosas investigaciones realizadas, aún persisten ciertas dudas sobre algunos aspectos de su comportamiento y las aplicaciones prácticas se llevan a cabo sólo con la ayuda de guías, sin que haya una normativa oficial. El objetivo de este trabajo es incrementar el conocimiento sobre esta técnica de refuerzo, y más concretamente, sobre el refuerzo a flexión de estructuras de fábrica. Con frecuencia el elemento reforzado es de hormigón armado y las láminas de FRP encoladas al exterior sirven para mejorar su resistencia a flexión, cortante o compresión (encamisados). Sin embargo su empleo en otros materiales como las estructuras de fábrica resulta muy prometedor. Las fábricas se caracterizan por soportar muy bien los esfuerzos de compresión pero bastante mal los de tracción. Adherir láminas de materiales compuestos puede servir para mejorar la capacidad resistente de elementos de fábrica sometidos a esfuerzos de flexión. Pero para ello, debe quedar garantizada una correcta adherencia entre el FRP y la fábrica, especialmente en edificios antiguos cuya superficie puede estar deteriorada por encontrarse a la intemperie o por el propio paso del tiempo. En el capítulo II se describen los objetivos fundamentales del trabajo y el método seguido. En el capítulo III se hace una amplia revisión del estado de conocimiento sobre el tema. En el apartado III.1 se detallan las principales características y propiedades mecánicas de fibras, matrices y materiales compuestos así como sus principales aplicaciones, haciendo especial hincapié en aspectos relativos a su durabilidad. En el apartado III.2 se incluye una revisión histórica de las líneas de investigación, tanto teóricas como empíricas, publicadas sobre estructuras de hormigón reforzadas a flexión encolando materiales compuestos. El apartado III.3 se centra en el aspecto fundamental de la adherencia refuerzo-soporte. Se hace un repaso a distintos modelos propuestos para prevenir el despegue distinguiendo si éste se inicia en la zona de anclaje o si está inducido por fisuras en la zona interior del elemento. Se observa falta de consenso en las propuestas. Además en este punto se relatan las campañas experimentales publicadas acerca de la adherencia entre materiales compuestos y fábricas. En el apartado III.4 se analizan las particularidades de las estructuras de fábrica. Además, se revisan algunas de las investigaciones relativas a la mejora de su comportamiento a flexión mediante láminas de FRP. El comportamiento mecánico de muros reforzados solicitados a flexión pura (sin compresión) ha sido documentado por varios autores, si bien es una situación poco frecuente en fábricas reales. Ni el comportamiento mecánico de muros reforzados solicitados a flexocompresión ni la incidencia que el nivel de compresión soportado por la fábrica tiene sobre la capacidad resistente del elemento reforzado han sido suficientemente tratados. En cuanto a los trabajos teóricos, las diferentes propuestas se basan en los métodos utilizados para hormigón armado y comparten los principios habituales de cálculo. Sin embargo, presentan diferencias relativas, sobre todo, a tres aspectos: 1) la forma de modelar el comportamiento de la fábrica, 2) el valor de deformación de cálculo del refuerzo, y 3) el modo de fallo que se considera recomendable buscar con el diseño. A pesar de ello, el ajuste con la parte experimental de cada trabajo suele ser bueno debido a una enorme disparidad en las variables consideradas. Cada campaña presenta un modo de fallo característico y la formulación que se propone resulta apropiada para él. Parece necesario desarrollar un método de cálculo para fábricas flexocomprimidas reforzadas con FRP que pueda ser utilizado para todos los posibles fallos, tanto atribuibles a la lámina como a la fábrica. En el apartado III.4 se repasan algunas lesiones habituales en fábricas solicitadas a flexión y se recogen ejemplos de refuerzos con FRP para reparar o prevenir estos daños. Para mejorar el conocimiento sobre el tema, se llevan a cabo dos pequeñas campañas experimentales realizadas en el Instituto de Ciencias de la Construcción Eduardo Torroja. La primera acerca de la adherencia de materiales compuestos encolados a fábricas deterioradas (apartado IV.1) y la segunda sobre el comportamiento estructural a flexocompresión de probetas de fábrica reforzadas con estos materiales (apartado IV.2). En el capítulo V se analizan algunos de los modelos de adherencia propuestos para prevenir el despegue del extremo del refuerzo. Se confirma que las predicciones obtenidas con ellos resultan muy dispares. Se recopila una base de datos con los resultados experimentales de campañas sobre adherencia de FRP a fábricas extraídas de la literatura y de los resultados propios de la campaña descrita en el punto IV.1. Esta base de datos permite conocer cual de los métodos analizados resulta más adecuado para dimensionar el anclaje de láminas de FRP adheridas a fábricas. En el capítulo VI se propone un método para la comprobación en agotamiento de secciones de fábrica reforzadas con materiales compuestos sometidas a esfuerzos combinados de flexión y compresión. Está basado en el procedimiento de cálculo de la capacidad resistente de secciones de hormigón armado pero adaptado a las fábricas reforzadas. Para ello, se utiliza un diagrama de cálculo tensión deformación de la fábrica de tipo bilineal (acorde con el CTE DB SE-F) cuya simplicidad facilita el desarrollo de toda la formulación al tiempo que resulta adecuado para predecir la capacidad resistente a flexión tanto para fallos debidos al refuerzo como a la fábrica. Además se limita la deformación de cálculo del refuerzo teniendo en consideración ciertos aspectos que provocan que la lámina adherida no pueda desarrollar toda su resistencia, como el desprendimiento inducido por fisuras en el interior del elemento o el deterioro medioambiental. En concreto, se propone un “coeficiente reductor por adherencia” que se determina a partir de una base de datos con 68 resultados experimentales procedentes de publicaciones de varios autores y de los ensayos propios de la campaña descrita en el punto IV.2. También se revisa la formulación propuesta con ayuda de la base de datos. En el capítulo VII se estudia la incidencia de las principales variables, como el axil, la deformación de cálculo del refuerzo o su rigidez, en la capacidad final del elemento. Las conclusiones del trabajo realizado y las posibles líneas futuras de investigación se exponen en el capítulo VIII. ABSTRACT Strengthening of existing structures with externally bonded fiber reinforced polymers (FRP) has become the most common application of advanced composite materials in construction. These materials exhibit many advantages in comparison with traditional ones (corrosion resistance, light weight, easy to apply, etc.). But despite countless researches have been done, there are still doubts about some aspects of their behaviour and applications are carried out only with the help of guidelines, without official regulations. The aim of this work is to improve the knowledge on this retrofitting technique, particularly in regard to flexural strengthening of masonry structures. Reinforced concrete is often the strengthened material and external glued FRP plates are used to improve its flexural, shear or compressive (by wrapping) capacity. However the use of this technique on other materials like masonry structures looks promising. Unreinforced masonry is characterized for being a good material to support compressive stresses but really bad to withstand tensile ones. Glue composite plates can improve the flexural capacity of masonry elements subject to bending. But a proper bond between FRP sheet and masonry must be ensured to do that, especially in old buildings whose surface can be damaged due to being outside or ageing. The main objectives of the work and the methodology carried out are described In Chapter II. An extensive overview of the state of art is done in Chapter III. In Section III.1 physical and mechanical properties of fibers, matrix and composites and their main applications are related. Durability aspects are especially emphasized. Section III.2 includes an historical overview of theoretical and empirical researches on concrete structures strengthened gluing FRP plates to improve their flexural behaviour. Section III.3 focuses on the critical point of bonding between FRP and substrate. Some theoretical models to prevent debonding of FRP laminate are reviewed, it has made a distinction between models for detachment at the end of the plate or debonding in the intermediate zones due to the effects of cracks. It is observed a lack of agreement in the proposals. Some experimental studies on bonding between masonry and FRP are also related in this chapter. The particular characteristics of masonry structures are analyzed in Section III.4. Besides some empirical and theoretical investigations relative to improve their flexural capacity with FRP sheets are reviewed. The mechanical behaviour of strengthened walls subject to pure bending (without compression) has been established by several authors, but this is an unusual situation for real masonry. Neither mechanical behaviour of walls subject to bending and compression nor influence of axial load in the final capacity of the strengthened element are adequately studied. In regard to theoretical studies, the different proposals are based on reinforced concrete analytical methods and share common design principles. However, they present differences, especially, about three aspects: 1) the constitutive law of masonry, 2) the value of ultimate FRP strain and 3) the desirable failure mode that must be looked for. In spite of them, a good agreement between each experimental program and its theoretical study is often exhibited due to enormous disparity in considered test parameters. Each experimental program usually presents a characteristic failure mode and the proposed formulation results appropriate for this one. It seems necessary to develop a method for FRP strengthened walls subject to bending and compression enable for all failure modes (due to FRP or masonry). Some common damages in masonry subject to bending are explained in Section III.4. Examples of FRP strengthening to repair or prevent these damages are also written. Two small experimental programs are carried out in Eduardo Torroja Institute to improve the knowledge on this topic. The first one is concerned about the bond between FRP plates and damaged masonry (section IV.1) and the second one is related to the mechanical behaviour of the strengthened masonry specimens subject to out of plane bending combined with axial force (section IV.2). In the Chapter V some bond models to prevent the debonding at the FRP plate end are checked. It is confirmed that their predictions are so different. A pure-shear test database is compiled with results from the existing literature and others from the experimental program described in section IV.1. This database lets know which of the considered model is more suitable to design anchorage lengths of glued FRP to masonry. In the Chapter VI a method to check unreinforced masonry sections with external FRP strengthening subject to bending and compression to the ultimate limit state is proposed. This method is based on concrete reinforced one, but it is adapted to strengthened masonry. A bilinear constitutive law is used for masonry (according to CTE DB SE-F). Its simplicity helps to develop the model formulation and it has proven to be suitable to predict bending capacity either for FRP failures or masonry crushing. With regard to FRP, the design strain is limited. It is taken into account different aspects which cause the plate can’t reach its ultimate strength, like intermediate FRP debonding induced by opening cracking or environmental damage. A “bond factor” is proposed. It is obtained by means of an experimental bending test database that includes 68 results from the existing literature and from the experimental program described in section IV.2. The proposed formulation has also been checked with the help of bending database. The effects of the main parameters, like axial load, FRP design effective strain or FRP stiffness, on the bending capacity of the strengthened element are studied in Chapter VII. Finally, the main conclusions from the work carried out are summarized in Chapter VIII. Future lines of research to be explored are suggested as well.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The European construction industry is supposed to consume the 40% of the natural European resources and to generate the 40% of the European solid waste. Conscious of the great damage being suffered by the environment because of construction activity, this work tries to provide the building actors with a new tool to improve the current situation. The tool proposed is a model for the comprehensive evaluation of construction products by determining their environmental level. In this research, the environmental level of a construction product has been defined as its quality of accomplishing the construction requirements needed by causing the minimum ecological impact in its surrounding environment. This information allows building actors to choose suitable materials for building needs and also for the environment, mainly in the project stage or on the building site, contributing to improve the relationship between buildings and environment. For the assessment of the environmental level of construction products, five indicators have been identified regarding their global environmental impact through the product life cycle: CO2 emissions provoked during their production, volume and toxicity of waste generated on the building site, durability and recycling capacity after their useful life. Therefore, the less environmental impact one construction product produces, the higher environmental level performs. The model has been tested in 30 construction products that include environmental criteria in their description. The results obtained will be discussed in this article. Furthermore, this model can lay down guidelines for the selection of ecoefficient construction products and the design of new eco-competitive and eco-committed ones

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Los montes Mediterráneos han experimentado múltiples cambios en las últimas décadas (tanto en clima como en usos), lo que ha conducido a variaciones en la distribución de especies. El aumento previsto de las temperaturas medias junto con la mayor variabilidad intra e inter anual en cuanto a la ocurrencia de eventos extremos o disturbios naturales (como periodos prolongados de sequía, olas de frío o calor, incendios forestales o vendavales) pueden dañar significativamente al regenerado, llevándolo hasta la muerte, y jugando un papel decisivo en la composición de especies y en la dinámica del monte. La amplitud ecológica de muchas especies forestales puede verse afectada, de forma que se esperan cambios en sus nichos actuales de regeneración. Sin embargo, la migración latitudinal de las especies en busca de mejores condiciones, podría ser una explicación demasiado simplista de un proceso mucho más complejo de interacción entre la temperatura y la precipitación, que afectaría a cada especie de un modo distinto. En este sentido tanto la capacidad de adaptación al estrés ambiental de una determinada especie, así como su habilidad para competir por los recursos limitados, podría significar variaciones dentro de una comunidad. Las características fisiológicas y morfológicas propias de cada especie se encuentran fuertemente relacionadas con el lugar donde cada una puede surgir, qué especies pueden convivir y como éstas responden a las condiciones ambientales. En este sentido, el conocimiento sobre las distintas respuestas ecofisiológicas observadas ante cambios ambientales puede ser fundamentales para la predicción de variaciones en la distribución de especies, composición de la comunidad y productividad del monte ante el cambio global. En esta tesis investigamos el grado de tolerancia y sensibilidad que cada una de las tres especies de estudio, coexistentes en el interior peninsular ibérico (Pinus pinea, Quercus ilex y Juniperus oxycedrus), muestra ante los factores abióticos de estrés típicos de la región Mediterránea. Nuestro trabajo se ha basado en la definición del nicho óptimo fisiológico para el regenerado de cada especie a través de la investigación en profundidad del efecto de la sequía, la temperatura y el ambiente lumínico. Para ello, hemos desarrollado un modelo de predicción de la tasa de asimilación de carbono que nos ha permitido identificar las condiciones óptimas ambientales donde el regenerado de cada especie podría establecerse con mayor facilidad. En apoyo a este trabajo y con la idea de estudiar el efecto de la sequía a nivel de toda la planta hemos desarrollado un experimento paralelo en invernadero. Aquí se han aplicado dos regímenes hídricos para estudiar las características fisiológicas y morfológicas de cada especie, sobre todo a nivel de raíz y crecimiento del tallo, y relacionarlas con las diferentes estrategias en el uso del agua de las especies. Por último, hemos estudiado los patrones de aclimatación y desaclimatación al frio de cada especie, identificando los periodos de sensibilidad a heladas, así como cuellos de botella donde la competencia entre especies podría surgir. A pesar de que el pino piñonero ha sido la especie objeto de la gestión de estas masas durante siglos, actualmente se encuentra en la posición más desfavorable para combatir el cambio global, presentado el nicho fisiológico más estrecho de las tres especies. La encina sin embargo, ha resultado ser la especie mejor cualificada para afrontar este cambio, seguida muy de cerca por el enebro. Nuestros resultados sugieren una posible expansión en el rango de distribución de la encina, un aumento en la presencia del enebro y una disminución progresiva del pino piñonero a medio plazo en estas masas. ABSTRACT Mediterranean forests have undergone multiple changes over the last decades (in both climate and land use), which have lead to variations in the distribution of species. The expected increase in mean annual temperature together with the greater inter and intra-annual variability in extreme events and disturbances occurrence (such as prolonged drought periods, cold or heat waves, wildfires or strong winds) can significantly damage natural regeneration, up to causing death, playing a decisive role on species composition and forest dynamics. The ecological amplitude for adaptation of many species can be affected in such a way that changes in the current regeneration niches of many species are expected. However, the forecasted poleward migration of species seeking better conditions could be an oversimplification of what is a more complex phenomenon of interactions among temperature and precipitation, that would affect different species in different ways. In this regard, either the ability to adapt to environmental stresses or to compete for limited resources of a single species in a mixed forest could lead to variations within a community. The ecophysiological and morphological traits specific to each species are strongly related to the place where each species can emerge, which species can coexist, and how they respond to environmental conditions. In this regard, the understanding of the ecophysiological responses observed against changes in environmental conditions can be essential for predicting variations in species distribution, community composition, and forest productivity in the context of global change. In this thesis we investigated the degree of tolerance and sensitivity that each of the three studied species, co-occurring in central of the Iberian Peninsula (Pinus pinea, Quercus ilex and Juniperus oxycedrus), show against the typical abiotic stress factors in the Mediterranean region. Our work is based on the optimal physiological niche for regeneration of each species through in-depth research on the effect of drought, temperature and light environment. For this purpose, we developed a model to predict the carbon assimilation rate which allows us to identify the optimal environmental conditions where regeneration from each species could establish itself more easily. To obtain a better understanding about the effect of low temperature on regeneration, we studied the acclimation and deacclimation patterns to cold of each species, identifying period of frost sensitivity, as well as bottlenecks where competition between species can arise. Finally, to support our results about the effect of water availabilty, we conducted a greenhouse experiment with a view of studying the drought effect at the whole plant level. Here, two watering regimes were applied in order to study the physiological and morphological traits of each species, mainly at the level of the root system and stem growth, and so relate them to the different water use strategies of the species. Despite the fact that stone pine has been the target species for centuries, nowadays this species is in the most unfavorable position to cope with climate change. Holm oak, however, resulted the species that is best adapted to tolerate the predicted changes, followed closely by prickly juniper. Our results suggest a feasible expansion of the distribution range in holm oak, an increase in the prickly juniper presence and a progressive decreasing of stone pine presence in the medium term in these stone pine-holm oak-prickly juniper mixed forests.