2 resultados para domestic water heater

em Universidad Politécnica de Madrid


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Many efforts have been made in order to adequate the production of a solar thermal collector field to the consumption of domestic hot water of the inhabitants of a building. In that sense, much has been achieved in different domains: research agencies, government policies and manufacturers. However, most of the design rules of the solar plants are based on steady state models, whereas solar irradiance, consumption and thermal accumulation are inherently transient processes. As a result of this lack of physical accuracy, thermal storage tanks are sometimes left to be as large as the designer decides without any aforementioned precise recommendation. This can be a problem if solar thermal systems are meant to be implemented in nowadays buildings, where there is a shortage of space. In addition to that, an excessive storage volume could not result more efficient in many residential applications, but costly, extreme in space consumption and in some cases too heavy. A proprietary transient simulation program has been developed and validated with a detailed measurement campaign in an experimental facility. In situ environmental data have been obtained through a whole year of operation. They have been gathered at intervals of 10 min for a solar plant of 50 m2 with a storage tank of 3 m3, including the equipment for domestic hot water production of a typical apartment building. This program has been used to obtain the design and dimensioning criteria of DHW solar plants under daily transient conditions throughout a year and more specifically the size of the storage tank for a multi storey apartment building. Comparison of the simulation results with the current Spanish regulation applicable, “Código Técnico de la Edificación” (CTE 2006), offers fruitful details and establishes solar facilities dimensioning criteria.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The energetic performance of landfill biogas (LB) and biodigester biogas (BB) from municipal waste was examined in consumption tests. These tests were performed in situ at a gas generation plant associated with a landfill facility in Madrid (Spain) and following the standard UNE-EN 30-2-1 (1999). The jets of a domestic cooker commonly used for natural gas (NG) or liquefied petroleum gas (LPG) were modified to operate with the biogases produced at the facility. The working pressures best suited to the tested gases, i.e., to avoid flashback and flame lift, and to ensure the stability and correct functioning of the flame during combustion, were determined by trial and error. Both biogases returned optimum energetic performance for the transfer of heat to water in a metallic recipient (as required by the above standard) at a supply pressure of 10 mbar. Domestic cookers are normally supplied with NG at a pressure of 20 mbar, at which pressure the energetic performance of G20 reference gas was higher than that of both biogases (52.84% compared to 38.06% and 49.77% respectively). Data concerning these issues involving also unexplored feedstock are required for the correct conversions of domestic cookers in order to avoid risks of serious personal injuries or property damages.