61 resultados para confinement, FRP, concrete, elliptical section, stress-strain behavior

em Universidad Politécnica de Madrid


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of fiber-reinforced polymer (FRP) composites for strengthening, repairing, or rehabilitating concrete structures has become more and more popular in the last 10 years. Irrespective of the type of strengthening used, design is conditioned, among others, by concrete-composite bond failure, normally attributed to stress at the interface between these two materials. Single shear, double shear, and notched beam tests are the bond tests most commonly used by the scientific community to estimate bond strength, effective length, and the bond stress-slip relationship. The present paper discusses the effect of concrete strength and adhesive thickness on the results of beam tests, which reproduce debonding conditions around bending cracks much more accurately. The bond stress-slip relationship was analyzed in a cross section near the inner edge, where stress was observed to concentrate. The ultimate load and the bond stress-slip relationship were visibly affected by concrete strength. Adhesive thickness, in turn, was found to have no significant impact on low-strength concrete but a somewhat greater effect on higher strength materials.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The fracture behavior of rock block contacts has been studied for many years. Unfortunately, up to now, there is not a rigorous formulation or a solid theoretical foundation to support it. A mathematical development to represent the failure mechanism which occurs in the contacts between rock blocks is presented to evaluate the performance of breaking mechanism of such blocks relating it to the morphology of the contact and mechanical parameters of the material. The examined framework includes the evaluation of the surface roughness of first order in the failure mechanism of the granular particles of large size and the development of a theoretical model describing the morphology of the contact between rock blocks.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The elastic strain/stress fields (halo) around a compressed amorphous nano-track (core) caused by a single high-energy ion impact on LiNbO3 are calculated. A method is developed to approximately account for the effects of crystal anisotropy of LiNbO3 (symmetry 3m) on the stress fields for tracks oriented along the crystal axes (X, Y or Z). It only considers the zero-order (axial) harmonic contribution to the displacement field in the perpendicular plane and uses effective Poisson moduli for each particular orientation. The anisotropy is relatively small; however, it accounts for some differential features obtained for irradiations along the crystallographic axes X, Y and Z. In particular, the irradiation-induced disorder (including halo) and the associated surface swelling appear to be higher for irradiations along the X- or Y-axis in comparison with those along the Z-axis. Other irradiation effects can be explained by the model, e.g. fracture patterns or the morphology of pores after chemical etching of tracks. Moreover, it offers interesting predictions on the effect of irradiation on lattice parameters

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Esta Tesis tiene como objetivo principal el desarrollo de métodos de identificación del daño que sean robustos y fiables, enfocados a sistemas estructurales experimentales, fundamentalmente a las estructuras de hormigón armado reforzadas externamente con bandas fibras de polímeros reforzados (FRP). El modo de fallo de este tipo de sistema estructural es crítico, pues generalmente es debido a un despegue repentino y frágil de la banda del refuerzo FRP originado en grietas intermedias causadas por la flexión. La detección de este despegue en su fase inicial es fundamental para prevenir fallos futuros, que pueden ser catastróficos. Inicialmente, se lleva a cabo una revisión del método de la Impedancia Electro-Mecánica (EMI), de cara a exponer sus capacidades para la detección de daño. Una vez la tecnología apropiada es seleccionada, lo que incluye un analizador de impedancias así como novedosos sensores PZT para monitorización inteligente, se ha diseñado un procedimiento automático basado en los registros de impedancias de distintas estructuras de laboratorio. Basándonos en el hecho de que las mediciones de impedancias son posibles gracias a una colocación adecuada de una red de sensores PZT, la estimación de la presencia de daño se realiza analizando los resultados de distintos indicadores de daño obtenidos de la literatura. Para que este proceso sea automático y que no sean necesarios conocimientos previos sobre el método EMI para realizar un experimento, se ha diseñado e implementado un Interfaz Gráfico de Usuario, transformando la medición de impedancias en un proceso fácil e intuitivo. Se evalúa entonces el daño a través de los correspondientes índices de daño, intentando estimar no sólo su severidad, sino también su localización aproximada. El desarrollo de estos experimentos en cualquier estructura genera grandes cantidades de datos que han de ser procesados, y algunas veces los índices de daño no son suficientes para una evaluación completa de la integridad de una estructura. En la mayoría de los casos se pueden encontrar patrones de daño en los datos, pero no se tiene información a priori del estado de la estructura. En este punto, se ha hecho una importante investigación en técnicas de reconocimiento de patrones particularmente en aprendizaje no supervisado, encontrando aplicaciones interesantes en el campo de la medicina. De ahí surge una idea creativa e innovadora: detectar y seguir la evolución del daño en distintas estructuras como si se tratase de un cáncer propagándose por el cuerpo humano. En ese sentido, las lecturas de impedancias se emplean como información intrínseca de la salud de la propia estructura, de forma que se pueden aplicar las mismas técnicas que las empleadas en la investigación del cáncer. En este caso, se ha aplicado un algoritmo de clasificación jerárquica dado que ilustra además la clasificación de los datos de forma gráfica, incluyendo información cualitativa y cuantitativa sobre el daño. Se ha investigado la efectividad de este procedimiento a través de tres estructuras de laboratorio, como son una viga de aluminio, una unión atornillada de aluminio y un bloque de hormigón reforzado con FRP. La primera ayuda a mostrar la efectividad del método en sencillos escenarios de daño simple y múltiple, de forma que las conclusiones extraídas se aplican sobre los otros dos, diseñados para simular condiciones de despegue en distintas estructuras. Demostrada la efectividad del método de clasificación jerárquica de lecturas de impedancias, se aplica el procedimiento sobre las estructuras de hormigón armado reforzadas con bandas de FRP objeto de esta tesis, detectando y clasificando cada estado de daño. Finalmente, y como alternativa al anterior procedimiento, se propone un método para la monitorización continua de la interfase FRP-Hormigón, a través de una red de sensores FBG permanentemente instalados en dicha interfase. De esta forma, se obtienen medidas de deformación de la interfase en condiciones de carga continua, para ser implementadas en un modelo de optimización multiobjetivo, cuya solución se haya por medio de una expansión multiobjetivo del método Particle Swarm Optimization (PSO). La fiabilidad de este último método de detección se investiga a través de sendos ejemplos tanto numéricos como experimentales. ABSTRACT This thesis aims to develop robust and reliable damage identification methods focused on experimental structural systems, in particular Reinforced Concrete (RC) structures externally strengthened with Fiber Reinforced Polymers (FRP) strips. The failure mode of this type of structural system is critical, since it is usually due to sudden and brittle debonding of the FRP reinforcement originating from intermediate flexural cracks. Detection of the debonding in its initial stage is essential thus to prevent future failure, which might be catastrophic. Initially, a revision of the Electro-Mechanical Impedance (EMI) method is carried out, in order to expose its capabilities for local damage detection. Once the appropriate technology is selected, which includes impedance analyzer as well as novel PZT sensors for smart monitoring, an automated procedure has been design based on the impedance signatures of several lab-scale structures. On the basis that capturing impedance measurements is possible thanks to an adequately deployed PZT sensor network, the estimation of damage presence is done by analyzing the results of different damage indices obtained from the literature. In order to make this process automatic so that it is not necessary a priori knowledge of the EMI method to carry out an experimental test, a Graphical User Interface has been designed, turning the impedance measurements into an easy and intuitive procedure. Damage is then assessed through the analysis of the corresponding damage indices, trying to estimate not only the damage severity, but also its approximate location. The development of these tests on any kind of structure generates large amounts of data to be processed, and sometimes the information provided by damage indices is not enough to achieve a complete analysis of the structural health condition. In most of the cases, some damage patterns can be found in the data, but none a priori knowledge of the health condition is given for any structure. At this point, an important research on pattern recognition techniques has been carried out, particularly on unsupervised learning techniques, finding interesting applications in the medicine field. From this investigation, a creative and innovative idea arose: to detect and track the evolution of damage in different structures, as if it were a cancer propagating through a human body. In that sense, the impedance signatures are used to give intrinsic information of the health condition of the structure, so that the same clustering algorithms applied in the cancer research can be applied to the problem addressed in this dissertation. Hierarchical clustering is then applied since it also provides a graphical display of the clustered data, including quantitative and qualitative information about damage. The performance of this approach is firstly investigated using three lab-scale structures, such as a simple aluminium beam, a bolt-jointed aluminium beam and an FRP-strengthened concrete specimen. The first one shows the performance of the method on simple single and multiple damage scenarios, so that the first conclusions can be extracted and applied to the other two experimental tests, which are designed to simulate a debonding condition on different structures. Once the performance of the impedance-based hierarchical clustering method is proven to be successful, it is then applied to the structural system studied in this dissertation, the RC structures externally strengthened with FRP strips, where the debonding failure in the interface between the FRP and the concrete is successfully detected and classified, proving thus the feasibility of this method. Finally, as an alternative to the previous approach, a continuous monitoring procedure of the FRP-Concrete interface is proposed, based on an FBGsensors Network permanently deployed within that interface. In this way, strain measurements can be obtained under controlled loading conditions, and then they are used in order to implement a multi-objective model updating method solved by a multi-objective expansion of the Particle Swarm Optimization (PSO) method. The feasibility of this last proposal is investigated and successfully proven on both numerical and experimental RC beams strengthened with FRP.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

En la actualidad muchas estructuras de hormigón armado necesitan ser reforzadas debido a diversas razones: errores en el proyecto o construcción, deterioro debido a efectos ambientales, cambios de uso o mayores requerimientos en los códigos. Los materiales compuestos, también conocidos como polímeros reforzados con fibras (FRP), están constituidos por fibras continuas de gran resistencia y rigidez embebidas en un material polimérico. Los FRP se utilizan cada vez más en aplicaciones estructurales debido a sus excelentes propiedades (elevadas resistencia y rigidez específicas y resistencia a la corrosión). Una de las aplicaciones más atractivas es el refuerzo de pilares mediante confinamiento para incrementar su resistencia y ductilidad. El confinamiento puede conseguirse pegando capas de FRP envolviendo el pilar en la dirección de los cercos (con las fibras orientadas en dirección perpendicular al eje del elemento). Se han realizado numerosos estudios experimentales en probetas cilíndricas pequeñas confinadas con encamisados de FRP y sometidas a compresión axial, y se han propuesto varios modelos sobre el hormigón confinado con FRP. Es sabido que el confinamiento de pilares de sección no circular es menos eficiente. En una sección circular, el FRP ejerce una presión de confinamiento uniforme sobre todo el perímetro, mientras que en una sección rectangular la acción de confinamiento se concentra en las esquinas. Esta tesis presenta los resultados de una investigación experimental sobre el comportamiento de probetas de hormigón de sección cuadrada confinadas con FRP y sometidas a compresión centrada. Se realizaron un total de 42 ensayos investigándose el comportamiento en las direcciones axial y transversal. Las variables del estudio incluyen: la resistencia del hormigón, el tipo de fibras (vidrio o carbono), la cuantía de refuerzo y el radio de curvatura de las esquinas. Los resultados de los ensayos realizados muestran que el confinamiento con FRP puede mejorar considerablemente la resistencia y ductilidad de pilares de hormigón armado de sección cuadrada con las esquinas redondeadas. La mejora conseguida es mayor en los hormigones de baja resistencia que en los de resistencia media. La deformación de rotura de la camisa de FRP es menor que la que se obtiene en ensayos de tracción normalizados del laminado, y la eficiencia del confinamiento depende en gran medida del radio de redondeo de las esquinas. Los resultados se han comparado con los obtenidos según los modelos teóricos más aceptados. Hay dos parámetros críticos en el ajuste de los modelos: el factor de eficiencia de la deformación y el efecto de confinamiento en secciones no circulares. Nowadays, many existing RC structures are in need of repair and strengthening for several reasons: design or construction errors, deterioration caused by environmental effects, change in use of the structures or revisions of code requirements. Composite materials, also known as fibre reinforced polymers (FRP), are composed of high strength and stiffness continuous fibres embedded in a polymer material. FRP materials are being increasingly used in many structural applications due to their excellent properties (high strength- and stiffness-toweight ratio, good corrosion behaviour). One of the most attractive applications of FRP is the confinement of concrete columns to enhance both strength and ductility. Concrete confinement can be achieved by bonding layers of hoop FRP around the column (fibres oriented perpendicular to the longitudinal axis). Many experimental studies have been conducted on small-scale plain concrete specimens of circular cross-sections confined with FRP and subjected to pure axial compressive loading, and several design models have been proposed to describe the behaviour of FRP-confined concrete. It is widely accepted that the confinement of non-circular columns is less efficient than the confinement of circular columns. In a circular cross section, the jacket exerts a uniform confining pressure over the entire perimeter. In the case of a rectangular cross section, the confining action is mostly concentrated at the corners. This thesis presents the results of a comprehensive experimental investigation on the behaviour of axially loaded square concrete specimens confined with FRP. A total of 42 compression tests were conducted, and the behaviour of the specimens in the axial and transverse directions were investigated. The parameters considered in this study are: concrete strength, type of fibres (glass or carbon), amount of FRP reinforcement and corner radius of the cross section. The tests results indicate that FRP confinement can enhance considerably the compressive strength and ductility of RC square columns with rounded corners. The enhancement is more pronounced for low- than for normal-strength concrete. The rupture strain of the FRP jacket is lower than the ultimate strain obtained by standard tensile testing of the FRP material, and the confinement efficiency significantly depends on the corner radius. The confined concrete behaviour was predicted according to the more accepted theoretical models and compared with experimental results. There are two key parameters which critically influence the fitting of the models: the strain efficiency factor and the effect of confinement in non-circular sections.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Prestressed structures are susceptible to relaxation losses which are of significant importance in structural design. After being manufactured, prestressing wires are coiled to make their storage and transportation easier. The possible deleterious effects of this operation on the stress relaxation behavior of prestressing steel wires are usually neglected, though it has been noticed by manufacturers and contractors that when relaxation tests are carried out after a long-time storage, on occasions relaxation losses are higher than those measured a short time after manufacturing. The influence of coiling on the relaxation losses is checked by means of experimental work and confirmed with a simple analytical model. The results show that some factors like initial residual stresses, excessively long-time storage or storage at high temperatures, can trigger or accentuate this damage. However, it is also shown that if the requirements of standards are fulfilled (minimum coiling diameters) these effects can be neglected.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Some experiments have been performed to investigate the cyclic freeze-thaw deterioration of concrete, using traditional and non-traditional techniques. Two concrete mixes, with different pore structure, were tested in order to compare the behavior of a freeze-thaw resistant concrete from one that is not. One of the concretes was air entrained, high content of cement and low w/c ratio, and the other one was a lower cement content and higher w/c ratio, without air-entraining agent. Concrete specimens were studied under cyclic freeze-thaw conditions according to UNE-CENT/TS 12390-9 test, using 3% NaCl solution as freezing medium (CDF test: Capillary Suction, De-icing agent and Freeze-thaw Test). The temperature and relative humidity were measured during the cycles inside the specimens using embedded sensors placed at different heights from the surface in contact with the de-icing agent solution. Strain gauges were used to measure the strain variations at the surface of the specimens. Also, measurements of ultrasonic pulse velocity through the concrete specimens were taken before, during, and after the freeze-thaw cycles. According to the CDF test, the failure of the non-air-entraining agent concrete was observed before 28 freeze-thaw cycles; contrariwise, the scaling of the air-entraining agent concrete was only 0.10 kg/m 2 after 28 cycles, versus 3.23 kg/m 2 in the deteriorated concrete, after 28 cycles. Similar behavior was observed on the strain measurements. The residual strain in the deteriorated concrete after 28 cycles was 1150 m versus 65 m, in the air-entraining agent concrete. By means of monitoring the changes of ultrasonic pulse velocity during the freeze-thaw cycles, the deterioration of the tested specimens were assessed

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Prestressed structures are susceptible to relaxation losses which are of significant importance in structural design. After being manufactured, prestressing wires are coiled to make their storage and transportation easier. The possible deleterious effects of this operation on the stress relaxation behavior of prestressing steel wires are usually neglected, though it has been noticed by manufacturers and contractors that when relaxation tests are carried out after a long-time storage, on occasions relaxation losses are higher than those measured a short time after manufacturing. The influence of coiling on the relaxation losses is checked by means of experimental work and confirmed with a simple analytical model. The results show that some factors like initial residual stresses, excessively long-time storage or storage at high temperatures,can trigger or accentuate this damage. However, it is also shown that if the requirements of standards are fulfilled (minimum coiling diameters) these effects can be neglected.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

El uso de refuerzos NSM‐FRP en estructuras de hormigón armado se ha incrementado considerablemente en los últimos años como método de refuerzo estructural. Los ensayos de arrancamiento en viga de los refuerzos NSM‐FRP permiten el estudio del comportamiento de la unión pegada. El principal objetivo del presente trabajo aborda la simulación numérica de este tipo de ensayos, con el propósito de caracterizar correctamente la adherencia entre las barras de NSM‐FRP y el hormigón. En una fase inicial se simuló un modelo bidimensional para conseguir evaluar y verificar el comportamiento de los elementos cohesivos y ver su comportamiento primero ante diferentes modelos de material y segundo ante un modo mixto de fallo, debido a la aplicación simultanea de carga axial y carga cortante. En una segunda fase se creó un modelo tridimensional para estudiar el arrancamiento de una barra de material compuesto insertada en hormigón, creando un modelo de material de hormigón y viendo el comportamiento cualitativo del sistema ante variaciones en los parámetros de los diferentes materiales. En la tercera fase, la más importante del presente trabajo, se abordó la simulación numérica del ensayo de arrancamiento en viga. Se simularon todos los componentes del ensayo y se evaluaron diferentes alternativas para representar la interfase NSM‐FRP ‐ hormigón, usando elementos cohesivos y diferentes distribuciones de los mismos en la interfase. Para conseguir representar lo más fielmente posible las condiciones del ensayo, se diseñó también un controlador PID que permite realizar las simulaciones numéricas mediante un control en desplazamientos, lo cual permite capturar más correctamente el comportamiento de reblandecimiento de la unión pegada. El controlador PID aplica técnicas de ingeniería de control para conseguir calcular a priori la amplitud necesaria del desplazamiento impuesto que provoque una evolución establecida en una variable interna del sistema. La variable usada para correlacionar los ensayos es la diferencia en desplazamientos entre dos puntos y se escoge una evolución lineal de la misma, pero en la tesis también se exponen los resultados de escoger otras posibles variables internas con diferentes evoluciones. Se compararon las simulaciones numéricas con resultados de mediciones experimentales previamente publicadas. Los resultados carga‐deslizamiento obtenidos encajan bien con los datos experimentales. El modelo propuesto es también capaz de predecir el modo de fallo en la interfase NSM‐FRP ‐ hormigón. Finalmente, también se han llevado a cabo estudios paramétricos, para evaluar la influencia de cada parámetro en los resultados. También se realizó un estudio cualitativo de cómo se comporta la unión pegada en cada momento de la simulación, mediante el uso macros y gráficas tridimensionales, para conseguir una mejor visualización y facilitar el análisis de los resultados. ABSTRACT The use of near‐surface mounted FRP reinforcement in reinforced concrete structures has seen a considerable increase in recent years as a strengthening method. Beam pull‐out tests for near‐surface reinforcement allow obtaining the local bond‐slip behavior of a bonded joint. The main objective of the current work deals with the three‐dimensional modeling of this kind of test with the purpose of characterizing suitably the mechanics of bond between FRP rods and concrete. In an initial stage, a two bidimensional in order to evaluate and to verify the behavior of the cohesive elements. Its behavior was evaluated first testing different material models and second testing the behavior when mixed mode failure appears, due to simultaneous axial and shear load. In a second stage a tridimensional model was created in order to study the pull‐out of an inserted beam of composite material in concrete. A concrete material model was created and the influence of each material parameter was studied qualitatively. The third part, the most relevant of the present work, the numerical simulation of the Beam Pull‐Out test was faced. All the parts of the Beam Pull‐Out test were included inthe simulation and different alternatives to represent the FRP bar – concrete interface have been evaluated, using cohesive elements and different distributions of them. In order to reproduce the test conditions more reliably, a PID controller has also been designed to conduct suitably the numerical tests in order to properly capture the softening branch of the load‐slip behaviour. The PID controller applies control techniques to calculate a priori the necessary amplitude of the load in order to achieve a given evolution through the simulation of an internal variable previously chosen. The variable used in order to correlate the simulation with the test results is the difference in displacements between two points and a linear evolution was chosen, but in the thesis the results of choosing other possible internal variables with different evolutions are also shown. The numerical FE simulations were compared with experimental measurements previously published. Load‐slip predictions compare well with the corresponding experimental data. The proposed model is also able to predict the failure mode at the FRP‐concrete interface. Some parametric studies have also been carried out, in order to evaluate the influence of each material parameter in the results. A qualitative study of the behaviour of the joint was also performed, using the results of the numeric simulations and through the use of macros and 3D graphs, the tensional state of each point of the joint can be visualized in each moment of the simulation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

En los últimos años ha habido una fuerte tendencia a disminuir las emisiones de CO2 y su negativo impacto medioambiental. En la industria del transporte, reducir el peso de los vehículos aparece como la mejor opción para alcanzar este objetivo. Las aleaciones de Mg constituyen un material con gran potencial para el ahorro de peso. Durante la última década se han realizado muchos esfuerzos encaminados a entender los mecanismos de deformación que gobiernan la plasticidad de estos materiales y así, las aleaciones de Mg de colada inyectadas a alta presión y forjadas son todavía objeto de intensas campañas de investigación. Es ahora necesario desarrollar modelos que contemplen la complejidad inherente de los procesos de deformación de éstos. Esta tesis doctoral constituye un intento de entender mejor la relación entre la microestructura y el comportamiento mecánico de aleaciones de Mg, y dará como resultado modelos de policristales capaces de predecir propiedades macro- y microscópicas. La deformación plástica de las aleaciones de Mg está gobernada por una combinación de mecanismos de deformación característicos de la estructura cristalina hexagonal, que incluye el deslizamiento cristalográfico en planos basales, prismáticos y piramidales, así como el maclado. Las aleaciones de Mg de forja presentan texturas fuertes y por tanto los mecanismos de deformación activos dependen de la orientación de la carga aplicada. En este trabajo se ha desarrollado un modelo de plasticidad cristalina por elementos finitos con el objetivo de entender el comportamiento macro- y micromecánico de la aleación de Mg laminada AZ31 (Mg-3wt.%Al-1wt.%Zn). Este modelo, que incorpora el maclado y tiene en cuenta el endurecimiento por deformación debido a las interacciones dislocación-dislocación, dislocación-macla y macla-macla, predice exitosamente las actividades de los distintos mecanismos de deformación y la evolución de la textura con la deformación. Además, se ha llevado a cabo un estudio que combina difracción de electrones retrodispersados en tres dimensiones y modelización para investigar el efecto de los límites de grano en la propagación del maclado en el mismo material. Ambos, experimentos y simulaciones, confirman que el ángulo de desorientación tiene una influencia decisiva en la propagación del maclado. Se ha observado que los efectos no-Schmid, esto es, eventos de deformación plástica que no cumplen la ley de Schmid con respecto a la carga aplicada, no tienen lugar en la vecindad de los límites de baja desorientación y se hacen más frecuentes a medida que la desorientación aumenta. Esta investigación también prueba que la morfología de las maclas está altamente influenciada por su factor de Schmid. Es conocido que los procesos de colada suelen dar lugar a la formación de microestructuras con una microporosidad elevada, lo cuál afecta negativamente a sus propiedades mecánicas. La aplicación de presión hidrostática después de la colada puede reducir la porosidad y mejorar las propiedades aunque es poco conocido su efecto en el tamaño y morfología de los poros. En este trabajo se ha utilizado un enfoque mixto experimentalcomputacional, basado en tomografía de rayos X, análisis de imagen y análisis por elementos finitos, para la determinación de la distribución tridimensional (3D) de la porosidad y de la evolución de ésta con la presión hidrostática en la aleación de Mg AZ91 (Mg- 9wt.%Al-1wt.%Zn) colada por inyección a alta presión. La distribución real de los poros en 3D obtenida por tomografía se utilizó como input para las simulaciones por elementos finitos. Los resultados revelan que la aplicación de presión tiene una influencia significativa tanto en el cambio de volumen como en el cambio de forma de los poros que han sido cuantificados con precisión. Se ha observado que la reducción del tamaño de éstos está íntimamente ligada con su volumen inicial. En conclusión, el modelo de plasticidad cristalina propuesto en este trabajo describe con éxito los mecanismos intrínsecos de la deformación de las aleaciones de Mg a escalas meso- y microscópica. Más especificamente, es capaz de capturar las activadades del deslizamiento cristalográfico y maclado, sus interacciones, así como los efectos en la porosidad derivados de los procesos de colada. ---ABSTRACT--- The last few years have seen a growing effort to reduce CO2 emissions and their negative environmental impact. In the transport industry more specifically, vehicle weight reduction appears as the most straightforward option to achieve this objective. To this end, Mg alloys constitute a significant weight saving material alternative. Many efforts have been devoted over the last decade to understand the main mechanisms governing the plasticity of these materials and, despite being already widely used, high pressure die-casting and wrought Mg alloys are still the subject of intense research campaigns. Developing models that can contemplate the complexity inherent to the deformation of Mg alloys is now timely. This PhD thesis constitutes an attempt to better understand the relationship between the microstructure and the mechanical behavior of Mg alloys, as it will result in the design of polycrystalline models that successfully predict macro- and microscopic properties. Plastic deformation of Mg alloys is driven by a combination of deformation mechanisms specific to their hexagonal crystal structure, namely, basal, prismatic and pyramidal dislocation slip as well as twinning. Wrought Mg alloys present strong textures and thus specific deformation mechanisms are preferentially activated depending on the orientation of the applied load. In this work a crystal plasticity finite element model has been developed in order to understand the macro- and micromechanical behavior of a rolled Mg AZ31 alloy (Mg-3wt.%Al-1wt.%Zn). The model includes twinning and accounts for slip-slip, slip-twin and twin-twin hardening interactions. Upon calibration and validation against experiments, the model successfully predicts the activity of the various deformation mechanisms and the evolution of the texture at different deformation stages. Furthermore, a combined three-dimensional electron backscatter diffraction and modeling approach has been adopted to investigate the effect of grain boundaries on twin propagation in the same material. Both experiments and simulations confirm that the misorientation angle has a critical influence on twin propagation. Non-Schmid effects, i.e. plastic deformation events that do not comply with the Schmid law with respect to the applied stress, are absent in the vicinity of low misorientation boundaries and become more abundant as misorientation angle increases. This research also proves that twin morphology is highly influenced by the Schmid factor. Finally, casting processes usually lead to the formation of significant amounts of gas and shrinkage microporosity, which adversely affect the mechanical properties. The application of hydrostatic pressure after casting can reduce the porosity and improve the properties but little is known about the effects on the casting’s pores size and morphology. In this work, an experimental-computational approach based on X-ray computed tomography, image analysis and finite element analysis is utilized for the determination of the 3D porosity distribution and its evolution with hydrostatic pressure in a high pressure diecast Mg AZ91 alloy (Mg-9wt.%Al-1wt.%Zn). The real 3D pore distribution obtained by tomography is used as input for the finite element simulations using an isotropic hardening law. The model is calibrated and validated against experimental stress-strain curves. The results reveal that the pressure treatment has a significant influence both on the volume and shape changes of individuals pores, which have been precisely quantified, and which are found to be related to the initial pore volume. In conclusion, the crystal plasticity model proposed in this work successfully describes the intrinsic deformation mechanisms of Mg alloys both at the mesoscale and the microscale. More specifically, it can capture slip and twin activities, their interactions, as well as the potential porosity effects arising from casting processes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An inverse optimization strategy was developed to determine the single crystal properties from experimental results of the mechanical behavior of polycrystals. The polycrystal behavior was obtained by means of the finite element simulation of a representative volume element of the microstructure in which the dominant slip and twinning systems were included in the constitutive equation of each grain. The inverse problem was solved by means of the Levenberg-Marquardt method, which provided an excellent fit to the experimental results. The iterative optimization process followed a hierarchical scheme in which simple representative volume elements were initially used, followed by more realistic ones to reach the final optimum solution, leading to important reductions in computer time. The new strategy was applied to identify the initial and saturation critical resolved shear stresses and the hardening modulus of the active slip systems and extension twinning in a textured AZ31 Mg alloy. The results were in general agreement with the data in the literature but also showed some differences. They were partially explained because of the higher accuracy of the new optimization strategy but it was also shown that the number of independent experimental stress-strain curves used as input is critical to reach an accurate solution to the inverse optimization problem. It was concluded that at least three independent stress-strain curves are necessary to determine the single crystal behavior from polycrystal tests in the case of highly textured Mg alloys.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La verificación de la seguridad estructural, tanto de estructuras que permitan un cierto grado de deterioro en su dimensionado como de estructuras existentes deterioradas, necesita disponer de modelos de resistencia que tengan en cuenta los efectos del deterioro. En el caso de la corrosión de las armaduras en las estructuras de hormigón armado, la resistencia depende de múltiples factores tales como la sección del acero corroído, el diagrama tensión-deformación del acero corroído, la adherencia hormigón-acero corroído, la fisuración o desprendimiento del hormigón debido a la expansión de los productos de corrosión. En este sentido, la transferencia de las fuerzas a través de la superficie de contacto entre el hormigón y el acero, la adherencia, es uno de los aspectos más importantes a considerar y es la base del comportamiento del hormigón armado como elemento estructural. La adherencia debe asegurar el anclaje de las armaduras y transmitir la tensión tangencial que aparece en las mismas como consecuencia de la variación de las solicitaciones a lo largo de un elemento estructural. Como consecuencia de la corrosión de las armaduras, el desarrollo de la adherencia se altera y, por tanto, la transferencia de la tensión longitudinal. Esta Tesis Doctoral aborda el comportamiento en estado límite último de la adherencia en el hormigón estructural con armaduras corroídas. El objetivo principal es la obtención de un modelo suficientemente realista y fiable para la evaluación de la adherencia con armaduras corroídas en el marco de la verificación de la seguridad estructural de elementos de hormigón armado con armaduras corroídas. Para ello se ha llevado a cabo un programa experimental de ensayos tipo pull-out excéntricos, con diferentes probetas, unas sin corrosión y otras sometidas tanto a procesos de corrosión natural como a procesos de corrosión acelerada, con diferentes grados de deterioro. Este tipo de ensayo de adherencia representa de forma realista y fiable realista los esfuerzos de adherencia en la zona de anclaje. Por otra parte, para la realización de estos ensayos se ha puesto a punto, además del procedimiento de ensayo, un sistema de adquisición de datos entre los que se incluye el empleo de sensores de tipo fibra óptica con redes de Bragg embebidos en la armadura para determinar los parámetros representativos de la adherencia en el hormigón estructural con armaduras corroídas. Por otra parte, la recopilación de los datos de los estudios de adherencia con armaduras corroídas procedentes de la literatura científica, además de los resultados de la presente investigación, junto con la identificación de las variables relevantes en el comportamiento de la adherencia con armaduras sanas y corroídas ha servido para la obtención de una formulación realista y fiable para la evaluación conjunta de la adherencia con armaduras sanas y corroídas a partir de modelos de regresión múltiple. La formulación propuesta ha sido validada mediante criterios estadísticos y comparada con otras formulaciones propuestas en la literatura científica. Además se ha realizado un análisis de las variables influyentes de la formulación propuesta. También se ha obtenido un modelo numérico simple y eficiente, validado con alguno de los ensayos realizados en esta tesis, para simular la adherencia con armaduras sanas y corroídas. Finalmente, se presenta un procedimiento para realizar la evaluación de vigas deterioradas por corrosión mediante el método de los campos de tensiones que incluye la evaluación de la adherencia mediante la formulación sugerida en esta Tesis Doctoral. Las conclusiones alcanzadas en este trabajo han permitido evaluar la adherencia con armaduras corroídas de forma realista y fiable. Asimismo, se ha podido incluir la evaluación de la adherencia en el marco de la verificación de la seguridad estructural en elementos de hormigón armado deteriorados por corrosión. ABSTRACT Structural safety verification of both structures allowing a certain degree of deterioration in design and deteriorated existing structures needs strength models that factor in the effects of deterioration. In case of corrosion of steel bars in reinforced concrete structures, the resistance depends on many things such as the remaining cross-section of the corroded reinforcement bars, the stress-strain diagrams of steel, the concrete-reinforcement bond and corrosion-induced concrete cracking or spalling. Accordingly, the force transfer through the contact surface between concrete and reinforcement, bond, is one of the most important aspects to consider and it is the basis of the structural performance of reinforced concrete. Bond must assure anchorage of reinforcement and transmit shear stresses as a consequence of the different stresses along a structural element As a consequence of corrosion, the bond development may be affected and hence the transfer of longitudinal stresses. This PhD Thesis deals with ultimate limit state bond behaviour in structural concrete with corrode steel bars. The main objective is to obtain a realistic and reliable model for the assessment of bond within the context of structural safety verifications of reinforced concrete members with corroded steel bars. In that context, an experimental programme of eccentric pull-out tests were conducted, with different specimens, ones without corrosion and others subjected to accelerated or natural corrosion with different corrosion degrees. This type of bond test reproduces in a realistic and reliable way bond stresses in the anchorage zone. Moreover, for conducting these tests it was necessary to develop both a test procedure and also a data acquisition system including the use of an embedded fibre-optic sensing system with fibre Bragg grating sensors to obtain the representative parameters of bond strength in structural concrete with corroded steel bars. Furthermore, the compilation of data from bond studies with corroded steel bars from scientific literature, including tests conducted in the present study, along with the identification of the relevant variables influencing bond behaviour for both corroded and non-corroded steel bars was used to obtain a realistic and reliable formulation for bond assessment in corroded and non-corroded steel bars by multiple linear regression analysis. The proposed formulation was validated with a number of statistical criteria and compared to other models from scientific literature. Moreover, an analysis of the influencing variables of the proposed formulation has been performed. Also, a simplified and efficient numerical model has been obtained and validated with several tests performed in this PhD Thesis for simulating the bond in corroded and non-corroded steel bars. Finally, a proposal for the assessment of corrosion-damaged beams with stress field models including bond assessment with the proposed formulation is presented. The conclusions raised in this work have allowed a realistic and reliable bond assessment in corroded steel bars. Furthermore, bond assessment has been included within the context of structural safety verifications in corrosion-damaged reinforced concrete elements.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fiber reinforced polymer composites (FRP) have found widespread usage in the repair and strengthening of concrete structures. FRP composites exhibit high strength-to-weight ratio, corrosion resistance, and are convenient to use in repair applications. Externally bonded FRP flexural strengthening of concrete beams is the most extended application of this technique. A common cause of failure in such members is associated with intermediate crack-induced debonding (IC debonding) of the FRP substrate from the concrete in an abrupt manner. Continuous monitoring of the concrete?FRP interface is essential to pre- vent IC debonding. Objective condition assessment and performance evaluation are challenging activities since they require some type of monitoring to track the response over a period of time. In this paper, a multi-objective model updating method integrated in the context of structural health monitoring is demonstrated as promising technology for the safety and reliability of this kind of strengthening technique. The proposed method, solved by a multi-objective extension of the particle swarm optimization method, is based on strain measurements under controlled loading. The use of permanently installed fiber Bragg grating (FBG) sensors embedded into the FRP-concrete interface or bonded onto the FRP strip together with the proposed methodology results in an automated method able to operate in an unsupervised mode.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Advanced composite materials are increasingly used in the strengthening of reinforced concrete (RC) structures. The use of externally bonded strips made of fibre-reinforced plastics (FRP) as strengthening method has gained widespread acceptance in recent years since it has many advantages over the traditional techniques. However, unfortunately, this strengthening method is often associated with a brittle and sudden failure caused by some form of FRP bond failure, originated at the termination of the FRP material or at intermediate areas in the vicinity of flexural cracks in the RC beam. Up to date, little effort in the early prediction of the debonding in its initial instants even though this effect is not noticeable by simple visual observation. An early detection of this phenomenon might help in taking actions to prevent future catastrophes. Fibre-optic Bragg grating (FBG) sensors are able to measure strains locally with high resolution and accuracy. Furthermore, as their physical size is extremely small compared with other strain measuring components, it enables to be embedded at the concrete-FRP interface for determining the strain distribution without influencing the mechanical properties of the host materials. This paper shows the development of a debonding identification methodology based on strains experimentally measured. For, it a simplified model is implemented to simulate the behaviour of FRP-strengthened reinforced concrete beams. This model is taken as a basis to. develop an model updating procedure able to detect minor debonding at the concrete-FRP interface from experimental strains obtained by using FBG sensors embedded at the interface

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Non-linear behavior of soils during a seismic event has a predominant role in current site response analysis. Soil response analysis consistently indicates that the stress-strain relationship of soils is nonlinear and shows hysteresis. When focusing in forced response simulations, time integrations based on modal analysis are widely considered, however parametric analysis, non-linear behavior and complex damping functions make difficult the online use of standard discretization strategies, e.g. those based on the use of finite element. In this paper we propose a new harmonic analysis formulation, able to address forced response simulation of soils exhibiting their characteristic nonlinear behavior. The solution can be evaluated in real-time from the offline construction of a parametric solution of the associated linearized problem within the Proper Generalized Decomposition framework.