11 resultados para bubbles
em Universidad Politécnica de Madrid
Resumo:
The dynamics of a gas-filled microbubble encapsulated by a viscoelastic fluid shell immersed in a Newtonian liquid and subject to an external pressure field is theoretically studied. The problem is formulated by considering a nonlinear Oldroyd type constitutive equation to model the rheological behavior of the fluid shell. Heat and mass transfer across the surface bubble have been neglected but radiation losses due to the compressibility of the surrounding liquid have been taken into account. Bubble collapse under sudden increase of the external pressure as well as nonlinear radial oscillations under ultrasound fields are investigated. The numerical results obtained show that the elasticity of the fluid coating intensifies oscillatory collapse and produces a strong increase of the amplitudes of radial oscillations which may become chaotic even for moderate driving pressure amplitudes. The role played by the elongational viscosity has also been analyzed and its influence on both, bubble collapse and radial oscillations, has been recognized. According to the theoretical predictions provided in the present work, a microbubble coated by a viscoelastic fluid shell is an oscillating system that, under acoustic driving, may experience volume oscillations of large amplitude, being, however, more stable than a free bubble. Thus, it could be expected that such a system may have a suitable behavior as an echogenic agent.
Resumo:
The aim of this work is to relate the curing conditions of concrete and the addition of an air-entraining admixture with the damage caused by freeze–thaw cycles. In countries with a continental climate, the curing of concrete in summer is performed under climatic conditions of high temperature and low humidity, and during the winter the concrete suffers conditions of freeze–thaw, often accompanied by the use of de-icing salts. This paper shows the experimental results of the behaviour of concrete specimens cured under climatic summer conditions (high temperature and low humidity) and then subjected to freeze–thaw cycles. Curing of the specimens includes conditions of good and bad practice in relation to wetting and protection of the concrete. It also examines the effectiveness of using an air-entraining admixture in both cases. The experimental programme includes an evaluation of the mechanical properties of the concrete, the study of the cement hydration and the measurement of the volume and pore sizes of the concrete. These tests were performed before and after the application of the freeze–thaw cycles. The results obtained showed that the specimens without air-entraining admixture show a deterioration of mechanical properties after the freeze–thaw test. However, the inclusion of air bubbles benefits the behaviour of concrete against freeze–thaw cycles so even better mechanical properties after the test were observed. This anomalous behaviour is because the cement hydration process continues over the freeze–thaw tests, closing the pore structure. This aspect has been confirmed with the DTA and TG tests performed
Resumo:
Pressure measurements on the surface of a 1:230 scale model of Bolund Island are presented. The model is smooth and no boundary layer generation has been considered since the experiment is designed as the simplest possible reference case. Measurement have been taken for a range of Reynolds numbers based on the average undisturbed wind speed U∞ and the maximum height of the island, h [1.7×104, 8.5×104], and for a range of wind directions. Four minutes time series of pressure in more than 400 points have been acquired and analysed to obtain the spatial distribution of both the time average and the variance of the pressure signal. The horizontal extension of the detachment bubble for the different Reynolds numbers and wind directions is identified by isobars and curves of constant value of pressure variance. The applicability of this technique for evaluating the horizontal topology of high turbulence regions associated to detachment bubbles after escarpments in potential wind farm sites is analysed. The results obtained shows that the behaviour of the mean pressure coefficient, Cp, the std. pressure coefficient, Cp, and the skewness of the pressure, Sp can be used to study the bubble over the island to a certain extent. This experiment is part of the set of different analysis on the Bolund test case that is being undertaken within WAUDIT project by the different scientific groups.
Resumo:
The ability to reproduce reduced gravity conditions for long periods is one of the reasons why the orbiting laboratory is so attractive. In this paper several fluid dynamics problem areas are reviewed in which zero-gravity conditions are of great importance. Although emphasis is placed on space processing, there are some older problems also in which gravity masks the phenomcna, impeding a reasonably simple approach to the solution. Three problems are considered: Thermal convection under reduced gravity. The dumping effect ofsurface gravity waves at the outset of convection induced by surface tractions is discussed in particular. The existence of convection is of concern for some satellite thermal control techniques presently used, and for most of the proposed manufacturing processes. Whereas convection should be normally avoided, problems related to the containerless stirring ofa melt constitute an exception. Secondly, gravity and chemical reactions. Although chemical reactions are independent of gravity because of the small mass of the molecules and atoms involved, in many cases the reaction rate dcpends on the arrival of the species to the reaction zone. When the arrival process is buoyancy-controlled, the net specd of the reaction will be affected by the gravity. Thirdly, two-phase flows under reduced gravity provkle interesting problems from boiling heat transfer to degasslng of melts. This part of the paper deals only with the measurement of sound veiocity in a liquid containing bubbles. It is suggested that such measurements should be mude under reduced gravity to provide reliable residís.
Resumo:
A new method is presented that increases the sensitivity of ultrasound-based techniques for detection of bacteria. The technique was developed for the detection of catalase-positive microorganisms. It uses a bubble trapping medium containing hydrogen peroxide that is mixed with the sample for microbiological evaluation. The enzyme catalase is present in catalase-positive bacteria, which induces a rapid hydrolysis of hydrogen peroxide, forming bubbles which remain in the medium. This reaction results in the amplification of the mechanical changes that the microorganisms produce in the medium. The effect can be detected by means of ultrasonic wave amplitude continuous measurement since the bubbles increase the ultrasonic attenuation significantly. It is shown that microorganism concentrations of the order of 105 cells ml−1 can be detected using this method. This allows an improvement of three orders of magnitude in the ultrasonic detection threshold of microorganisms in conventional culture media, and is competitive with modern rapid microbiological methods. It can also be used for the characterization of the enzymatic activity.
Resumo:
Los métodos de detección rápida de microorganismos se están convirtiendo en una herramienta esencial para el control de calidad en el área de la biotecnología, como es el caso de las industrias de alimentos y productos farmacéuticos y bioquímicos. En este escenario, el objetivo de esta tesis doctoral es desarrollar una técnica de inspección rápida de microoganismos basada en ultrasonidos. La hipótesis propuesta es que la combinación de un dispositivo ultrasónico de medida y un medio líquido diseñado específicamente para producir y atrapar burbujas, pueden constituir la base de un método sensible y rápido de detección de contaminaciones microbianas. La técnica presentada es efectiva para bacterias catalasa-positivas y se basa en la hidrólisis del peróxido de hidrógeno inducida por la catalasa. El resultado de esta reacción es un medio con una creciente concentración de burbujas. Tal medio ha sido estudiado y modelado desde el punto de vista de la propagación ultrasónica. Las propiedades deducidas a partir del análisis cinemático de la enzima se han utilizado para evaluar el método como técnica de inspección microbiana. En esta tesis, se han investigado aspectos teóricos y experimentales de la hidrólisis del peróxido de hidrógeno. Ello ha permitido describir cuantitativamente y comprender el fenómeno de la detección de microorganismos catalasa-positivos mediante la medida de parámetros ultrasónicos. Más concretamente, los experimentos realizados muestran cómo el oxígeno que aparece en forma de burbujas queda atrapado mediante el uso de un gel sobre base de agar. Este gel fue diseñado y preparado especialmente para esta aplicación. A lo largo del proceso de hidrólisis del peróxido de hidrógeno, se midió la atenuación de la onda y el “backscattering” producidos por las burbujas, utilizando una técnica de pulso-eco. Ha sido posible detectar una actividad de la catalasa de hasta 0.001 unidades/ml. Por otra parte, este estudio muestra que por medio del método propuesto, se puede lograr una detección microbiana para concentraciones de 105 células/ml en un periodo de tiempo corto, del orden de unos pocos minutos. Estos resultados suponen una mejora significativa de tres órdenes de magnitud en comparación con otros métodos de detección por ultrasonidos. Además, la sensibilidad es competitiva con modernos y rápidos métodos microbiológicos como la detección de ATP por bioluminiscencia. Pero sobre todo, este trabajo muestra una metodología para el desarrollo de nuevas técnicas de detección rápida de bacterias basadas en ultrasonidos. ABSTRACT In an industrial scenario where rapid microbiological methods are becoming essential tools for quality control in the biotechnological area such as food, pharmaceutical and biochemical; the objective of the work presented in this doctoral thesis is to develop a rapid microorganism inspection technique based on ultrasounds. It is proposed that the combination of an ultrasonic measuring device with a specially designed liquid medium, able to produce and trap bubbles could constitute the basis of a sensitive and rapid detection method for microbial contaminations. The proposed technique is effective on catalase positive microorganisms. Well-known catalase induced hydrogen peroxide hydrolysis is the fundamental of the developed method. The physical consequence of the catalase induced hydrogen peroxide hydrolysis is an increasingly bubbly liquid medium. Such medium has been studied and modeled from the point of view of ultrasonic propagation. Properties deduced from enzyme kinematics analysis have been extrapolated to investigate the method as a microbial inspection technique. In this thesis, theoretical and experimental aspects of the hydrogen peroxide hydrolysis were analyzed in order to quantitatively describe and understand the catalase positive microorganism detection by means of ultrasonic measurements. More concretely, experiments performed show how the produced oxygen in form of bubbles is trapped using the new gel medium based on agar, which was specially designed for this application. Ultrasonic attenuation and backscattering is measured in this medium using a pulse-echo technique along the hydrogen peroxide hydrolysis process. Catalase enzymatic activity was detected down to 0.001 units/ml. Moreover, this study shows that by means of the proposed method, microbial detection can be achieved down to 105 cells/ml in a short time period of the order of few minutes. These results suppose a significant improvement of three orders of magnitude compared to other ultrasonic detection methods for microorganisms. In addition, the sensitivity reached is competitive with modern rapid microbiological methods such as ATP detection by bioluminescence. But above all, this work points out a way to proceed for developing new rapid microbial detection techniques based on ultrasound.
Resumo:
La configuración de un cilindro acoplado a una semi-esfera, conocida como ’hemispherecylinder’, se considera como un modelo simplificado para numerosas aplicaciones industriales tales como fuselaje de aviones o submarinos. Por tanto, el estudio y entendimiento de los fenómenos fluidos que ocurren alrededor de dicha geometría presenta gran interés. En esta tesis se muestra la investigación del origen y evolución de los, ya conocidos, patrones de flujo (burbuja de separación, vórtices ’horn’ y vórtices ’leeward’) que se dan en esta geometría bajo condiciones de flujo separado. Para ello se han llevado a cabo simulaciones numéricas (DNS) y ensayos experimentales usando la técnica de Particle Image Velocimetry (PIV), para una variedad de números de Reynolds (Re) y ángulos de ataque (AoA). Se ha aplicado sobre los resultados numéricos la teoría de puntos críticos obteniendo, por primera vez para esta geometría, un diagrama de bifurcaciones que clasifica los diferentes regímenes topológicos en función del número de Reynolds y del ángulo de ataque. Se ha llevado a cabo una caracterización completa sobre el origen y la evolución de los patrones estructurales característicos del cuerpo estudiado. Puntos críticos de superficie y líneas de corriente tridimensionales han ayudado a describir el origen y la evolución de las principales estructuras presentes en el flujo hasta alcanzar un estado de estabilidad desde el punto de vista topológico. Este estado se asocia con el patrón de los vórtices ’horn’, definido por una topología característica que se encuentra en un rango de números de Reynolds muy amplio y en regímenes compresibles e incompresibles. Por otro lado, con el objeto de determinar las estructuras presentes en el flujo y sus frecuencias asociadas, se han usado distintas técnicas de análisis: Proper Orthogonal Decomposition (POD), Dynamic Mode Decomposition (DMD) y análisis de Fourier. Dichas técnicas se han aplicado sobre los datos experimentales y numéricos, demostrándose la buena concordancia entre ambos resultados. Finalmente, se ha encontrado en ambos casos, una frecuencia dominante asociada con una inestabilidad de los vórtices ’leeward’. ABSTRACT The hemisphere-cylinder may be considered as a simplified model for several geometries found in industrial applications such as aircrafts’ fuselages or submarines. Understanding the complex flow phenomena that surrounds this particular geometry is therefore of major industrial interest. This thesis presents an investigation of the origin and evolution of the complex flow pattern; i.e. separation bubbles, horn vortices and leeward vortices, around the hemisphere-cylinder under separated flow conditions. To this aim, threedimensional Direct Numerical Simulations (DNS) and experimental tests, using Particle Image Velocimetry (PIV) techniques, have been performed for a variety of Reynolds numbers (Re) and angles of attack (AoA). Critical point theory has been applied to the numerical simulations to provide, for the first time for this geometry, a bifurcation diagram that classifies the different flow topology regimes as a function of the Reynolds number and the angle of attack. A complete characterization about the origin and evolution of the complex structural patterns of this geometry has been put in evidence. Surface critical points and surface and volume streamlines were able to describe the main flow structures and their strong dependence with the flow conditions up to reach the structurally stable state. This state was associated with the pattern of the horn vortices, found on ranges from low to high Reynolds numbers and from incompressible to compressible regimes. In addition, different structural analysis techniques have been employed: Proper Orthogonal Decomposition (POD), Dynamic Mode Decomposition (DMD) and Fourier analysis. These techniques have been applied to the experimental and numerical data to extract flow structure information (i.e. modes and frequencies). Experimental and numerical modes are shown to be in good agreement. A dominant frequency associated with an instability of the leeward vortices has been identified in both, experimental and numerical results.
Resumo:
Pressure measurements on the surface of a 1:230 scale model of Bolund Island are presented. The model is smooth and no boundary layer generation has been considered since the experiment is designed as the simplest possible reference case. Measurement have been taken for a range of Reynolds numbers based on the average undisturbed wind speed U? and the maximum height of the island, h [1.7×104 , 8.5×104], and for a range of wind directions. Four minutes time series of pressure in more than 400 points have been acquired and analysed to obtain the spatial distribution of both the time average and the variance of the pressure signal. The horizontal extension of the detachment bubble for the different Reynolds numbers and wind directions is identified by isobars and curves of constant value of pressure variance. The applicability of this technique for evaluating the horizontal topology of high turbulence regions associated to detachment bubbles after escarpments in potential wind farm sites is analysed. The results obtained shows that the behaviour of the mean pressure coefficient, Cp, the std. pressure coefficient, C?p, and the skewness of the pressure, Sp can be used to study the bubble over the island to a certain extent. This experiment is part of the set of different analysis on the Bolund test case that is being undertaken within WAUDIT project by the different scientific groups.
Resumo:
Here we show that potassium-doped tungsten foil should be preferred to pure tungsten foil when considering tungsten laminate pipes for structural divertor applications. Potassium-doped tungsten materials are well known from the bulb industry and show an enhanced creep and recrystallization behaviour that can be explained by the formation of potassium-filled bubbles that are surrounding the elongated grains, leading to an interlocking of the microstructure. In this way, the ultra-fine grained (UFG) microstructure of tungsten foil can be stabilized and with it the extraordinary mechanical properties of the foil in terms of ductility, toughness, brittle-to-ductile transition, and radiation resistance. In this paper we show the results of three-point bending tests performed at room temperature on annealed pure tungsten and potassium-doped tungsten foils (800, 900, 1000, 1100, 1200, 1300, 1400, 1600, 1800, 2000, 2200, and 2400 °C for 1 h in vacuum). The microstructural assessment covers the measurement of the hardness and analyses of fractured surfaces as well as a comparison of the microstructure by optical microscopy. The results show that there is a positive effect of potassium-doped tungsten foils compared to pure tungsten foil and demonstrate the potential of the doped foil
Resumo:
The theoretical study of forced bubble oscillations is motivated by the importance of cavitation bubbles and oscillating encapsulated microbubbles (i.e. contrast agents) in medical sciences. In more details,theoretical studies on bubble dynamics addressing the sound-bubble interaction phenomenon provide the basis for understanding the dynamics of contrast agent microbubbles used in medical diagnosis and of non-linearly oscillating cavitation bubbles in the case of high-intensity ultrasound therapy. Moreover, the inclusion of viscoelasticity is of vital importance for an accurate theoretical analysis since most biological tissues and fluids exhibit non-Newtonian behavior.
Resumo:
La presente tesis doctoral aborda el estudio de un nuevo material mineral, compuesto principalmente por una matriz de yeso (proveniente de un conglomerante industrial basado en sulfato de calcio multifase) y partículas de aerogel de sílice hidrófugo mesoporoso, compatibilizadas mediante un surfactante polimérico, debido a su alto carácter hidrófugo. La investigación se centra en conocer los factores que influyen en las propiedades mecánicas y conductividad térmica del material compuesto generado. Este estudio pretende contribuir al conocimiento sobre el desarrollo de nuevos morteros de elevado aislamiento térmico que puedan ser utilizados en la rehabilitación energética de edificios de viviendas existentes, debido a que estos representan gran parte del consumo energético del parque de viviendas de España, aunque también a nivel internacional. De los materiales utilizados para desarrollar los morteros estudiados, el yeso, además de ser un material muy abundante, especialmente en España, requiere una menor cantidad de energía para la fabricación de un conglomerante (debido a una menor temperatura de fabricación), en comparación con el cemento o la cal, por lo que presenta una menor huella de carbono que estos últimos. Por otro lado, el aerogel de sílice hidrófugo mesoporoso es, de acuerdo con la documentación disponible, el material que posee actualmente la mayor capacidad de aislamiento térmico en el mercado. El desarrollo de nuevos morteros minerales con una capacidad de aislamiento térmico mayor que los materiales aislantes utilizados tradicionalmente, tiene una aplicación relevante en los casos de rehabilitación energética de edificios históricos y patrimoniales, en los que se requiere la aplicación del aislamiento por el interior de la fachada, ya que este tipo de soluciones tienen el inconveniente de reducir el espacio habitable de las áreas involucradas, especialmente en zonas climáticas en las que el aislamiento térmico puede suponer un espesor considerable, por lo que es ideal utilizar materiales de altas prestaciones de aislamiento térmico capaces de aportar el mismo nivel de aislamiento (o incluso mayor), pero en un espesor considerablemente menor. La investigación se desarrolla en tres etapas: bibliográfica, experimental y de simulación. La primera etapa, parte del estudio de la bibliografía existente, relacionada con materiales aislantes, incluyendo soluciones basadas, tanto en morteros aislantes, como en paneles de aislamiento térmico. La segunda, de carácter experimental, se centra en estudiar la influencia de la microestrucrura y macroestructura, del nuevo material mineral, en las propiedades físicas elementales, mecánicas y conductividad térmica del compuesto. La tercera etapa, mediante una simulación del consumo energético, consiste en cuantificar teóricamente el potencial ahorro energético que puede aportar este material en un caso de rehabilitación energética en particular. La investigación experimental se centró principalmente en conocer los factores principales que influyen en las propiedades mecánicas y conductividad térmica de los materiales compuestos minerales desarrollados en esta tesis. Para ello, se llevó a cabo una caracterización de los materiales de estudio, así como el desarrollo de distintas muestras de ensayo, de tal forma que se pudo estudiar, tanto la hidratación del yeso en los compuestos, como su posterior microestructura y macroestructura, aspectos fundamentales para el entendimiento de las propiedades mecánicas y conductividad térmica del compuesto aislante. De este modo, se pudieron conocer y cuantificar, los factores que influyen en las propiedades estudiadas, aportando una base de conocimiento y entendimiento de este tipo de compuestos minerales con aerogel de sílice hidrófugo, no existiendo estudios publicados hasta el momento de finalización de esta tesis, con la aproximación al material propuesta en este estudio, ni con yeso (basado en sulfato de calcio multifase), ni con otro tipo de conglomerantes. Particularmente, se determinó la influencia que tiene la incorporación de partículas de aerogel de sílice hidrófugo, en grandes proporciones en volumen, en un compuesto mineral basado en distintas fases de sulfato de calcio. No obstante, para llevar a cabo las mezclas, fue necesario utilizar un surfactante para compatibilizar este tipo de partículas, con el conglomerante basado en agua. El uso de este tipo de aditivos tiene una influencia, no solo en el aerogel, sino en las propiedades del compuesto en general, dependiendo de su concentración, por lo que se establecieron dos porcentajes de adición: la primera, determinada a partir de la cantidad mínima necesaria para compatibilizar las mezclas (0,1% del agua de amasado), y la segunda, como límite superior, la concentración utilizada habitualmente a nivel industrial para estabilizar burbujas de aire en hormigones espumados (5%). El surfactante utilizado mostró la capacidad de modificar la superficie del aerogel, cambiando el comportamiento de las partículas frente al agua, permitiendo una invasión parcial de su estructura porosa, por parte del agua de amasado. Este comportamiento supone un aumento muy importante en la relación agua/yeso, afectando el hábito cristalino e influenciando negativamente las propiedades mecánicas de la matriz de yeso, presentando un efecto aún notable a mayor concentración de surfactante (5%). En cuanto a las propiedades finales alcanzadas, fue posible lograr un compuesto mineral ultraligero (200 kg/m3), con alrededor de un 60% de aerogel en volumen y de alta capacidad aislante (0,028 W/m•K), presentando una conductividad térmica notablemente menor que los morteros aislantes del mercado, e incluso también menor que la de los aislantes tradicionales basado en las lanas minerales o EPS; no obstante, con la limitante de presentar bajas propiedades mecánicas, condicionando su posible aplicación futura. Entre los factores principales relacionados con las propiedades mecánicas, se encontró que estas dependen exponencialmente del volumen de yeso en el compuesto; no obstante, factores de segundo orden, como el grado de hidratación, o una mejor distribución del conglomerante entre las partículas de aerogel, debido al aumento de la superficie específica del polvo mineral, pueden aumentar las propiedades mecánicas entre el doble y el triple, dependiendo del volumen de aerogel en cuestión. Además, se encontró que el aerogel, en conjunto con el surfactante, es capaz de introducir una gran cantidad de aire (0,70 m3 por cada m3 de aerogel), que unido al agua evaporada (no consumida por el conglomerante durante la hidratación), el volumen de aire total alcanza, generalmente, un 40%, independientemente de la cantidad de aerogel en la mezcla. De este modo, el aire introducido en la matriz desplaza las proporciones en volumen del aerogel y del yeso, disminuyendo, tanto las propiedades mecánicas, como la capacidad aislante de compuesto mineral. Por otro lado, la conductividad térmica mostró tener una dependencia directa de la contribución de las tres fases principales en el compuesto: yeso, aerogel y aire ocluido. De este modo, se pudo desarrollar un modelo matemático, adaptado de uno existente, capaz de calcular, con bastante precisión, la relación de los tres componentes mencionados, en la conductividad térmica de los compuestos, para el rango de volúmenes y materiales utilizados en esta tesis. Finalmente, la simulación del consumo energético realizada a una vivienda típica de España, de los años 1900 a 1959 (basada en muros de ladrillo macizo), para las zonas climáticas estudiadas (A, D y E), permitió observar el potencial ahorro energético que puede aportar este material, dependiendo de su espesor, como aislamiento interior de los muros de fachada. Particularmente, para la zona A, se determinó un espesor óptimo de 1 cm, mientras que para la zona D y E, 3,5 y 3,9 cm respectivamente. En este sentido, el nuevo material estudiado es capaz de disminuir, entre un 35% y un 80%, el espesor de la capa aislante, en comparación con paneles de lana de roca o los morteros minerales de mayor capacidad aislante del mercado español respectivamente. ABSTRACT The present doctoral thesis studies a new mineral-based composite material, composed by a gypsum matrix (based on an industrial multiphase gypsum binder) and mesoporous hydrophobic silica aerogel particles, compatibilized with a polymeric surfactant due to the high hydrophobic character of the insulating particles. This study pretends to contribute to the development of new composite insulating materials that could be used in energy renovation of existing dwellings, in order to reduce their high energy consumption, as they represent a great part of the total energy consumed in Spain, but also internationally. Between the materials used to develop de studied insulating mortars, gypsum, besides being an abundant material, especially in Spain, requires less energy for the manufacture of a mineral binder (due to lower manufacturing temperatures), compared to lime or cement, thus presenting lower carbon footprint. In other hand, the hydrophobic mesoporous silica aerogel, is, according to the existing references, the material with the highest know insulating capacity in the market. The development of new mineral mortars with higher thermal insulation capacity than traditional insulating materials, presents a relevant application in energy retrofitting of historic and cultural heritage buildings, in which implies that the insulating material should be installed as an internal layer, rather than as an external insulating system. This type of solution involves a reduced internal useful area, especially in climatic zones where the demand for thermal insulation is higher, and so the insulating layer thickness, being idealistic to use materials with very high insulating properties, in order to reach same insulating level (or higher), but in lower thickness than the provided by traditional insulating materials. This research is developed in three main stages: bibliographic, experimental and simulation. The first stage starts by studying the existing references regarding thermally insulating materials, including existing insulating mortars and insulating panels. The second stage, mainly experimental, is centered in the study of the the influence of the microstructure and macrostructure in the physical and mechanical properties, and also in the thermal conductivity of the new mineral-based material. The thirds stage, through energy simulation, consists in theoretically quantifying the energy savings potential that can provide this type of insulating material, in a particular energy retrofitting case study. The experimental research is mainly focused in the study of the factors that influence the mechanical properties and the thermal conductivity of the thermal insulating mineral composites developed in this thesis. For this, the characterization of the studied materials has been performed, as well as the development of several experimental samples, in order to study the hydration of the mineral binder within the composites, but also the final microstructure and macrostructure, fundamental aspects for the understanding of the composite’s mechanical and insulating properties. Thus, is was possible to determine and quantify the factors that influence the studied material properties, providing a knowledge base and understanding of mineral composites that comprises mesoporous hydrophobic silica aerogel particles, being the first study up to date regarding the specific approach of the present study, regarding not just multiphase calcium sulfate plaster, but also other mineral binders. Particularly, the influence of the incorporation of hydrophobic silica aerogel particles, in high volume ratios into a mineral compound, based on different phases of calcium sulfate has been determined. However, to perform mixing, it is necessary to use a surfactant in order to compatibilize these particles with the water-based mineral binder. The use of such additives has an influence, not only in the aerogel, but the overall properties of the compound, so two different surfactant concentration has been studied: the first, the minimum amount of surfactant (used in this thesis) in order to develop the slurries (0.1% concentration of the mixing water), and the second, as the upper limit, the concentration usually used industrially to stabilize air bubbles in foamed concrete (5%). One of the side effects of using such additive, was the modification of the aerogel particles, by changing their behavior in respect to water, generating a partial invasion of the aerogel’s porous structure, by the mixing water. This behavior produces a very important increase in water/binder ratios, affecting the crystal habit and negatively influencing the mechanical properties of the gypsum matrix. This effect further increased when a higher concentration of surfactant (5%) is used. Regarding final materials properties, it was possible to achieve an ultra-lightweight mineral composite (200 kg/m3), with around 60% by volume of aerogel, presenting a very high insulating capacity (0.028 W/m•K), a noticeable lower thermal conductivity compared to the insulating mortars and traditional thermal insulating panels on the market, such as mineral wool or EPS; however, the limiting factor for future’s material application in buildings, is related to the very low mechanical properties achieved. Among the main factors related to the mechanical properties, it has been found an exponential correlation to the volume of gypsum in the composite. However, second-order factors such as the degree of hydration, or a better distribution of the binder between the aerogel particles, due to the increased surface area of the mineral powder, can increase the mechanical properties between two to three times, depending aerogel volume involved. In addition, it was found that the aerogel, together with the surfactant, is able to entrain a large amount of air volume (around 0.70 m3 per m3 of aerogel), which together with the evaporated water (not consumed by the binder during hydration), can reach generally around 40% of entrained air within the gypsum matrix, regardless of the amount of aerogel in the mixture. Thus, the entrained air into the matrix displaces the volume proportions of the aerogel and gypsum, reducing both mechanical and insulating properties of the mineral composite. On the other hand, it has been observed a direct contribution of three main phases into the thermal conductivity of the composite: gypsum, aerogel and entrained air. Thus, it was possible to develop a mathematical model (adapted from an existing one), capable of calculating quite accurate the thermal conductivity of such mineral composites, from the ratio these three components and for the range of volumes and materials used in this thesis. Finally, the energy simulation performed to a typical Spanish dwelling, from the years 1900 to 1959 (mainly constructed with massive clay bricks), within three climatic zones of Spain (A, D and E), showed the energy savings potential that can provide this type of insulating material, depending on the thickness of the applied layer. Particularly, for the climatic A zone, it has been found an optimal layer thickness of 1 cm, while for zone D and E, 3.5 and 3.9 cm respectively. In this manner, the new studied materials is capable of decreasing the thickness of the insulating layer by 35% and 80%, compared with rock wool panels or mineral mortars with the highest insulating performance of the Spanish market respectively.