8 resultados para average refractive-index change
em Universidad Politécnica de Madrid
Resumo:
The refractive index changes induced by swift ion-beam irradiation in silica have been measured either by spectroscopic ellipsometry or through the effective indices of the optical modes propagating through the irradiated structure. The optical response has been analyzed by considering an effective homogeneous medium to simulate the nanostructured irradiated system consisting of cylindrical tracks, associated to the ion impacts, embedded into a virgin material. The role of both, irradiation fluence and stopping power, has been investigated. Above a certain electronic stopping power threshold (∼2.5 keV/nm), every ion impact creates an axial region around the trajectory with a fixed refractive index (around n = 1.475) corresponding to a certain structural phase that is independent of stopping power. The results have been compared with previous data measured by means of infrared spectroscopy and small-angle X-ray scattering; possible mechanisms and theoretical models are discussed.
Resumo:
The refractive index and extinction coefficient of chemical vapour deposition grown graphene are determined by ellipsometry analysis. Graphene films were grown on copper substrates and transferred as both monolayers and bilayers onto SiO2/Si substrates by using standard manufacturing procedures. The chemical nature and thickness of residual debris formed after the transfer process were elucidated using photoelectron spectroscopy. The real layered structure so deduced has been used instead of the nominal one as the input in the ellipsometry analysis of monolayer and bilayer graphene, transferred onto both native and thermal silicon oxide. The effect of these contamination layers on the optical properties of the stacked structure is noticeable both in the visible and the ultraviolet spectral regions, thus masking the graphene optical response. Finally, the use of heat treatment under a nitrogen atmosphere of the graphene-based stacked structures, as a method to reduce the water content of the sample, and its effect on the optical response of both graphene and the residual debris layer are presented. The Lorentz-Drude model proposed for the optical response of graphene fits fairly well the experimental ellipsometric data for all the analysed graphene-based stacked structures.
Resumo:
Liquid crystal devices are being used in many non-display applications in order to construct small devices controlled by low voltage electronics without mechanical components. In this work, we present a novel liquid crystal device for laser beam steering. In this device the orientation of the liquid crystal molecules can be controlled. A change in the liquid crystal orientation results in a change of the refractive index. When a laser beam passes through the device, the beam will be deviated (Fig.1) and the device works a prism. The main difference between this device and a prism is that in the device the orientation profile of the liquid crystal molecules can be modified so that the laser beam can be deviated a required angle: the device is tuneable.
Resumo:
Spherical symmetric refractive index distributions also known as Gradient Index lenses such as the Maxwell-Fish-Eye (MFE), the Luneburg or the Eaton lenses have always played an important role in Optics. The recent development of the technique called Transformation Optics has renewed the interest in these gradient index lenses. For instance, Perfect Imaging within the Wave Optics framework has recently been proved using the MFE distribution. We review here the design problem of these lenses, classify them in two groups (Luneburg moveable-limits and fixed-limits type), and establish a new design techniques for each type of problem.
Resumo:
Classical spherical gradient index (GRIN) lenses (such as Maxwell Fish Eye lens, Eaton lens, Luneburg lens, etc.) design procedure using the Abel integral equation is reviewed and reorganized. Each lens is fully defined by a function called the angle of flight which describes the ray deflection through the lens. The radial refractive index distribution is obtained by applying a linear integral transformation to the angle of flight. The interest of this formulation is in the linearity of the integral transformation which allows us to derive new solutions from linear combinations of known lenses. Beside the review of the classical GRIN designs, we present a numerical method for GRIN lenses defined by the Abel integral equation with fixed limits, which is an ill-posed problem.
Resumo:
The field of optical label free biosensors has become a topic of interest during past years, with devices based on the detection of angular or wavelength shift of optical modes [1]. Common parameters to characterize their performance are the Limit of Detection (LOD, defined as the minimum change of refractive index upon the sensing surface that the device is able to detect, and also BioLOD, which represents the minimum amount of target analyte accurately resolved by the system; with units of concentration (common un its are p pm, ng/ml, or nM). LOD gives a first value to compare different biosensors, and is obtained both theoretically (using photonic calculation tools), and experimentally,covering the sensing area with fluids of different refractive indexes.
Resumo:
El interés por los sistemas fotovoltaicos de concentración (CPV) ha resurgido en los últimos años amparado por el desarrollo de células multiunión de muy alta eficiencia basadas en semiconductores de los grupos III-V. Estas células han permitido obtener módulos de concentración con eficiencias que prácticamente duplican las del panel plano y que llegan al 35% en los módulos récord. Esta tesis está dedicada al diseño y la implementación experimental de nuevos conceptos que permitan obtener módulos CPV que no sólo alcancen una eficiencia alta en condiciones estándar sino que, además, sean lo suficientemente tolerantes a errores de montaje, seguimiento, temperatura y variaciones espectrales para que la energía que producen a lo largo del año sea máxima. Una de las primeras cuestiones que se abordan es el diseño de elementos ópticos secundarios para sistemas cuyo primario es una lente de Fresnel y que permiten, para una concentración fija, aumentar el ángulo de aceptancia y la tolerancia del sistema. Varios secundarios reflexivos y refractivos han sido diseñados y analizados mediante trazado de rayos. En particular, utilizando óptica anidólica y basándose en el diseño de una sola etapa conocido como ‘concentrador dieléctrico que funciona por reflexión total interna‘, se ha diseñado, fabricado y caracterizado un secundario con salida cuadrada que, usado junto con una lente de Fresnel, permite alcanzar simultáneamente una elevada eficiencia, concentración y aceptancia. Además, se ha propuesto y prototipado un método alternativo de fabricación para otro de los secundarios, denominado domo, consistente en el sobremoldeo de silicona sobre células solares. Una de las características que impregna todo el trabajo realizado en esta tesis es la aproximación holística en el diseño de módulos CPV, es decir, se ha prestado especial atención al diseño conjunto de la célula y la óptica para garantizar que el sistema total alcance la mayor eficiencia posible. En este sentido muchos sistemas ópticos desarrollados en esta tesis han sido diseñados, caracterizados y optimizados teniendo en cuenta que el ajuste de corriente entre las distintas subcélulas que comprenden la célula multiunión bajo el concentrador sea muy próximo a uno. La capa antirreflectante sobre la célula funciona, en cierto modo, como interfaz entre la óptica y la célula, por lo que se ha diseñado un método de optimización de capas antirreflectantes que considera no sólo el amplio rango de longitudes de onda para el que las células multiunión son sensibles sino también la distribución angular de intensidad sobre la célula creada por la óptica de concentración. Además, la cuestión de la falta de uniformidad también se ha abordado mediante la comparación de las distribuciones espectrales y espaciales de irradiancia que crean diferentes ópticas (simuladas mediante trazado de rayos y fotografiadas) y las pérdidas de eficiencia que experimentan las células iluminadas por dichas ópticas de concentración medidas experimentalmente. El efecto de la temperatura en la óptica de concentración también ha sido objeto de estudio de esta tesis. En particular, mediante simulaciones de elementos finitos se han dado los primeros pasos para el análisis de las deformaciones que sufren los dientes de las lentes de Fresnel híbridas (vidrio-silicona), así como el cambio de índice de refracción con la temperatura y la influencia de ambos efectos sobre el funcionamiento de los sistemas. Se ha implementado un modelo que tiene por objeto considerar las variaciones ambientales, principalmente temperatura y contenido espectral de la radiación directa, así como las sensibilidades térmica y espectral de los sistemas CPV, con el fin de maximizar la energía producida por un módulo de concentración a lo largo de un año en un emplazamiento determinado. Los capítulos 5 y 6 de este libro están dedicados al diseño, fabricación y caracterización de un nuevo concepto de módulo fotovoltaico denominado FluidReflex y basado en una única etapa reflexiva con dieléctrico fluido. En este nuevo concepto la presencia del fluido aporta algunas ventajas significativas como son: un aumento del producto concentración por aceptancia (CAP, en sus siglas en inglés) alcanzable al rodear la célula con un medio cuyo índice de refracción es mayor que uno, una mejora de la eficiencia óptica al disminuir las pérdidas por reflexión de Fresnel en varias interfaces, una mejora de la disipación térmica ya que el calor que se concentra junto a la célula se trasmite por convección natural y conducción en el fluido y un aislamiento eléctrico mejorado. Mediante la construcción y medida de varios prototipos de unidad elemental se ha demostrado que no existe ninguna razón fundamental que impida la implementación práctica del concepto teórico alcanzando una elevada eficiencia. Se ha realizado un análisis de fluidos candidatos probando la existencia de al menos dos de ellos que cumplen todos los requisitos (en particular el de estabilidad bajo condiciones de luz concentrada) para formar parte del sistema de concentración FluidReflex. Por ´ultimo, se han diseñado, fabricado y caracterizado varios prototipos preindustriales de módulos FluidReflex para lo cual ha sido necesario optimizar el proceso de fabricación de la óptica multicavidad a fin de mantener el buen comportamiento óptico obtenido en la fabricación de la unidad elemental. Los distintos prototipos han sido medidos, tanto en el laboratorio como bajo el sol real, analizando el ajuste de corriente de la célula iluminada por el concentrador FluidReflex bajo diferentes distribuciones espectrales de la radiación incidente así como el excelente comportamiento térmico del módulo. ABSTRACT A renewed interest in concentrating photovoltaic (CPV) systems has emerged in recent years encouraged by the development of high-efficiency multijunction solar cells based in IIIV semiconductors that have led to CPV module efficiencies which practically double that of flat panel PV and which reach 35% for record modules. This thesis is devoted to the design and experimental implementation of new concepts for obtaining CPV modules that not only achieve high efficiency under standard conditions but also have such a wide tolerance to assembly errors, tracking, temperature and spectral variations, that the energy generated by them throughout the year is maximized. One of the first addressed issues is the design of secondary optical elements whose primary optics is a Fresnel lens and which, for a fixed concentration, allow an increased acceptance angle and tolerance of the system. Several reflective and refractive secondaries have been designed and analyzed using ray tracing. In particular, using nonimaging optics and based on the single-stage design known as ‘dielectric totally internally reflecting concentrator’, a secondary with square output has been designed, fabricated and characterized. Used together with a Fresnel lens, the secondary can simultaneously achieve high efficiency, concentration and acceptance. Furthermore, an alternative method has been proposed and prototyped for the fabrication of the secondary named dome. The optics is manufactured by direct overmolding of silicone over the solar cells. One characteristic that permeates all the work done in this thesis is the holistic approach in the design of CPV modules, meaning that special attention has been paid to the joint design of the solar cell and the optics to ensure that the total system achieves the highest attainable efficiency. In this regard, many optical systems developed in the thesis have been designed, characterized and optimized considering that the current matching among the subcells within the multijunction solar cell beneath the optics must be close to one. Antireflective coating over the cell acts, somehow, as an interface between the optics and the cell. Consequently, a method has been designed to optimize antireflective coatings that takes into account not only the broad wavelength range that multijunction solar cells are sensitive to but also the angular intensity distribution created by the concentrating optics. In addition, the issue of non-uniformity has also been addressed by comparing the spectral and spatial distributions of irradiance created by different optics (simulated by ray tracing and photographed) and the efficiency losses experienced by cells illuminated by those concentrating optics experimentally determined. The effect of temperature on the concentrating optics has also been studied in this thesis. In particular, finite element simulations have been use to analyze the deformations experienced by the facets of hybrid (silicon-glass) Fresnel lenses, the change of refractive index with temperature and the influence of both effects on the system performance. A model has been implemented which take into consideration atmospheric variations, mainly temperature and spectral content of the direct normal irradiance, as well as thermal and spectral sensitivities of systems, with the aim of maximizing the energy harvested by a CPV module throughout the year in a particular location. Chapters 5 and 6 of this book are devoted to the design, fabrication, and characterization of a new concentrator concept named FluidReflex and based on a single-stage reflective optics with fluid dielectric. In this new concept, the presence of the fluid provides some significant advantages such as: an increased concentration acceptance angle product (CAP) achievable by surrounding the cell with a medium whose refractive index is greater than one, an improvement of the optical efficiency by reducing losses due to Fresnel reflection at several interfaces, an improvement in heat dissipation as the heat concentrated near the cell is transmitted by natural convection and conduction in the fluid, and an improved electrical insulation. By fabricating and characterizing several elementary-unit prototypes it was shown that there is no fundamental reason that prevents the practical implementation of this theoretical concept reaching high efficiency. Several fluid candidates were investigated proving the existence of at least to fluids that meet all the requirements (including the stability under concentrated light) to become part of the FluidReflex concentrator. Finally, several pre-industrial FluidReflex module prototypes have been designed and fabricated. An optimization process for the manufacturing of the multicavity optics was necessary to attain such an optics quality as the one achieved by the single unit. The module prototypes have been measured, both indoors and outdoors, analyzing the current matching of the solar cells beneath the concentrator for different spectral distribution of the incident irradiance. Additionally, the module showed an excellent thermal performance.
Resumo:
El presente trabajo de Tesis se ha centrado en el diseño, fabricación y caracterización de dispositivos basados en fibras de cristal fotónico infiltrado selectivamente con cristales líquidos, polímeros y una mezcla de ambos. Todos los dispositivos son sintonizables, y su área de aplicación se centra en comunicaciones ópticas y sensores. La manipulación y fusionado de fibras fotónicas, el llenado selectivo de determinadas cavidades y la alineación recíproca de fibras mantenedoras de polarización son tareas muy específicas y delicadas para las que se requieren protocolos muy estrictos. Previo a la fabricación de dispositivos ha sido necesaria por tanto una tarea de sistematización y creación de protocolos de fabricación. Una vez establecidos se ha procedido a la fabricación y caracterización de dispositivos. Los dispositivos fabricados se enumeran a continuación para posteriormente detallar una a una las singularidades de cada uno. • Interferómetros intermodales hechos a partir de una porción de fibra fotónica soldada entre dos fibras estándar, bien monomodo o PANDA (mantenedora de polarización). Estos interferómetros han sido sumergidos o bien llenados selectivamente con cristales líquidos para así sintonizar la señal interferométrica guiada a través de la fibra. • Infiltración de fibras fotónicas con cristales líquidos colestéricos con especial énfasis en la fase azul (blue phase) de estos materiales. Las moléculas de cristal líquido se autoalinean en volumen por lo que la infiltración de fibras fotónicas con estos cristales líquidos es muy interesante, pues es conocida la dificultad de alinear apropiadamente cristales líquidos dentro de cavidades micrométricas de las fibras fotónicas. • Grabación de redes holográficas de forma selectiva en las cavidades de una fibra fotónica. Estas redes holográficas, llamadas POLICRYPS (POlymer-LIquid CRYstal-Polymer Slices), son redes fabricadas a base de franjas de polímero y cristal líquido alineado perpendicularmente a dichas franjas. Las franjas son a su vez perpendiculares al eje de la fibra como lo puede ser una red de Bragg convencional. El cristal líquido, al estar alineado perpendicularmente a dichos franjas y paralelo al eje de la fibra, se puede conmutar aplicando un campo eléctrico externo, modificando así el índice efectivo de la red. Se puede fabricar por lo tanto una red de Bragg sintonizable en fibra, muy útil en comunicaciones ópticas. • Llenado selectivo de fibras fotónicas con polidimetilsiloxano (PDMS), un polímero de tipo silicona. Si se realiza un llenado selectivo asimétrico se puede inducir birrefringencia en la fibra. El índice de refracción del PDMS tiene una fuerte dependencia térmica, por lo que se puede sintonizar la birrefringencia de la fibra. • Estudio teórico de llenado selectivo de fibras fotónicas con PDMS dopado con nanopartículas de plata de 5, 40 y 80 nm. Estas nanopartículas poseen un pico de absorción en torno a los 450 nm debido a resonancias superficiales localizadas de plasmones (LSPR). La resonancia del plasmon tiene una fuerte dependencia con el índice de refracción del material colindante, y al ser éste PDMS, la variación de índice de refracción se ve amplificada, obteniendo una absorción sintonizable. Se ha propuesto la fabricación de polarizadores sintonizables usando esta técnica. Como ya se ha dicho, previamente a la fabricación ha sido necesaria la protocolización de diversos procedimientos de fabricación de alta complejidad, así como protocolizar el proceso de toma de medidas para optimizar los resultados. Los procedimientos que han requerido la formulación de protocolos específicos han sido los siguientes: • Llenado selectivo de cavidades en una fibra fotónica. Dichas fibras tienen generalmente un diámetro externo de 125 μm, y sus cavidades son de entre 5 y 10 μm de diámetro. Se han desarrollado tres técnicas diferentes para el llenado/bloqueado selectivo, pudiéndose combinar varios protocolos para la optimización del proceso. Las técnicas son las siguientes: o Llenado y bloqueado con un prepolímero. Dicho prepolímero, también llamado adhesivo óptico, está inicialmente en estado líquido y posee una cierta viscosidad. Las cavidades de la fibra fotónica que se desea llenar o bloquear poseen un diámetro diferente al resto, por lo que en el proceso de llenado aparecen dos frentes de llenado dependientes de su diámetro. A mayor diámetro, mayor velocidad de llenado. Polimerizando cuando existe dicha diferencia en los frentes se puede cortar por medio, obteniendo así una fibra parcialmente bloqueada. o Colapsamiento de las cavidades de menor diámetro mediante aplicación de calor. El calor producido por un arco voltaico de una soldadora de fibra estándar fusiona el material exterior de la fibra produciendo el colapsamiento de las cavidades de menor diámetro. En esta técnica también es necesaria una diferencia de diámetros en las cavidades de la fibra. o Bloqueo una a una de las cavidades de la fibra fotónica con adhesivo óptico. Este procedimiento es muy laborioso y requiere mucha precisión. Con este sistema se pueden bloquear las cavidades deseadas de una fibra sin importar su diámetro. • Alineación de una fuente de luz linealmente polarizada con una fibra mantenedora de polarización ya sea PANDA o fotónica. Así mismo también se han alineado entre sí fibras mantenedoras de polarización, para que sus ejes rápidos se fusionen paralelos y así el estado de polarización de la luz guiada se mantenga. • Sistematización de toma de medidas para caracterizar los interferómetros modales. Éstos son altamente sensibles a diversas variables por lo que el proceso de medida es complejo. Se deben aislar variables de forma estrictamente controlada. Aunque todos los dispositivos tienen en común el llenado selectivo de cavidades en una fibra fotónica cada dispositivo tiene sus peculiaridades, que van a ser explicadas a continuación. ABSTRACT The present Thesis has been centered in the design, fabrication and characterization of devices based on photonic crystal fibers selectively filled with liquid crystals, polymers and a mixture of both. All devices are tunable and their work field is optical communications and sensing The handling and splicing of photonic crystal fibers, the selective filling of their holes and the aligning of polarization maintaining fibers are very specific and delicate tasks for which very strict protocols are required. Before the fabrication of devices has therefore been necessary task systematization and creation of manufacturing protocols. Once established we have proceeded to the fabrication and characterization of devices. The fabricated devices are listed below and their peculiarities are detailed one by one: • Intermodal interferometers made with a portion of photonic crystal fiber spliced between two optical communication fiber pigtails, either single mode or PANDA (polarization-maintaining) fiber. These interferometers have been submerged or selectively filled with liquid crystals to tune the interferometric guided signal. • Infiltration of photonic fibers with cholesteric liquid crystals with special emphasis on their blue phase (blue phase). The liquid crystal molecules are self-aligning in volume so the infiltration of photonic fibers with these liquid crystals is very interesting. It is notoriously difficult to properly align liquid crystals within micron cavities such as photonic fibers. • Selectively recording of holographic gratings in the holes of photonic crystal fibers. These holographic gratings, called POLICRYPS (POlymer-LIquid CRYstal-Polymes Slices), are based on walls made of polymer and liquid crystal aligned perpendicular to them. These walls are perpendicular to the axis of the fiber as it can be a conventional Bragg grating. The liquid crystal is aligned perpendicular to the walls and parallel to the fiber axis, and can be switched by applying an external electric field and thus change the effective index of the grating. It is thus possible to manufacture a tunable Bragg grating fiber, useful in optical communications. •Asymmetrically selective filling of photonic crystal fibers with a silicone polymer like called polydimethylsiloxane (PDMS) to induce birefringence in the fiber. The refractive index of PDMS has temperature dependence, so that the birefringence of the fiber can be tuned. • Theoretical study of photonic crystal fibers selectively filled with PDMS doped with silver nanoparticles of 5, 40 and 80 nm. These nanoparticles have an absorption peak around 450 nm due to localized surface plasmon resonances (LSPR). Plasmon resonance has a strong dependence on the refractive index of the adjacent material, and as this is PDMS, the refractive index variation is amplified, obtaining a tunable absorption. Fabrication of tunable polarizers using this technique has been proposed. Before starting the fabrication, it has been necessary to optimize several very delicate procedures and different protocols have been designed. The most delicate procedures are as follows: • Selective filling of holes in a photonic crystal fiber. These fibers generally have an outer diameter of 125 μm, and their holes have a diameter around between 5 and 10 μm. It has been developed three different techniques for filling / selective blocking, and they can be combined for process optimization. The techniques are: o Filling and blocked with a prepolymer. This prepolymer also called optical adhesive is initially in liquid state and has a certain viscosity. The holes of the photonic crystal fiber that are desired to be filled or blocked should have a different diameter, so that in the filling process appear two different fronts depending on the hole diameter. The holes with larger diameter are filled faster. Then the adhesive is polymerized when there is such a difference on the front. A partially blocked fiber is obtained cutting between fronts. o Collapsing of holes of smaller diameter by application of heat. The heat produced by an arc of a standard fusion splicer fuses the outer fiber material producing the collapsing of the cavities of smaller diameter. In this technique also you need a difference of diameters in the fiber holes. o Blocking one by one the holes of photonic crystal fiber with optical adhesive. This procedure is very laborious and requires great precision. This system can block unwanted cavities regardless fiber diameter. • Aligning a linearly polarized light source with a polarization-maintaining fiber (either a PANDA fiber as a photonic crystal fiber). It is needed also an aligning between polarization-maintaining fibers, so that their fast axes parallel merge and that is state of polarization of light guided is maintained. • Systematization of taking measurements to characterize the modal interferometers. These are highly sensitive to several variables so the measurement process is very complicated. Variables must be fixed in a very controlled manner. Although all devices have the common characteristic of being selectively filled PCFs with some kind of material, each one has his own peculiarities, which are explained below.