8 resultados para air-sealed test
em Universidad Politécnica de Madrid
Resumo:
We present and validate a test able to provide reliable body sway measurements in air pistol shooting, without the use of a gun. 46 senior male pistol shooters who participated in Spanish air pistol championships participated in the study. Body sway data of two static bipodal balance tests have been compared: during the first test, shooting was simulated by use of a dumbbell, while during the second test the shooters own pistol was used. Both tests were performed the day previous to the competition, during the official training time and at the training stands to simulate competition conditions. The participants performance was determined as the total score of 60 shots at competition. Apart from the commonly used variables that refer to movements of the shooters centre of pressure (COP), such as COP displacements on the X and Y axes, maximum and average COP velocities and total COP area, the present analysis also included variables that provide information regarding the axes of the COP ellipse (length and angle in respect to X). A strong statistically significant correlation between the two tests was found (with an interclass correlation varying between 0.59 and 0.92). A statistically significant inverse linear correlation was also found between performance and COP movements. The study concludes that dumbbell tests are perfectly valid for measuring body sway by simulating pistol shooting.
Resumo:
Several issues concerning the current use of speech interfaces are discussed and the design and development of a speech interface that enables air traffic controllers to command and control their terminals by voice is presented. A special emphasis is made in the comparison between laboratory experiments and field experiments in which a set of ergonomics-related effects are detected that cannot be observed in the controlled laboratory experiments. The paper presents both objective and subjective performance obtained in field evaluation of the system with student controllers at an air traffic control (ATC) training facility. The system exhibits high word recognition test rates (0.4% error in Spanish and 1.5% in English) and low command error (6% error in Spanish and 10.6% error in English in the field tests). Subjective impression has also been positive, encouraging future development and integration phases in the Spanish ATC terminals designed by Aeropuertos Españoles y Navegación Aérea (AENA).
Resumo:
Underground coal mines explosions generally arise from the inflammation of a methane/air mixture. This explosion can also generate a subsequent coal dust explosion. Traditionally such explosions have being fought eliminating one or several of the factors needed by the explosion to take place. Although several preventive measures are taken to prevent explosions, other measures should be considered to reduce the effects or even to extinguish the flame front. Unlike other protection methods that remove one or two of the explosion triangle elements, namely; the ignition source, the oxidizing agent and the fuel, explosion barriers removes all of them: reduces the quantity of coal in suspension, cools the flame front and the steam generated by vaporization removes the oxygen present in the flame. Passive water barriers are autonomous protection systems against explosions that reduce to a satisfactory safety level the effects of methane and/or flammable dust explosions. The barriers are activated by the pressure wave provoked in the explosion destroying the barrier troughs and producing a uniform dispersion of the extinguishing agent throughout the gallery section in quantity enough to extinguish the explosion flame. Full scale tests have been carried out in Polish Barbara experimental mine at GIG Central Mining Institute in order to determine the requirements and the optimal installation conditions of these devices for small sections galleries which are very frequent in the Spanish coal mines. Full scale tests results have been analyzed to understand the explosion timing and development, in order to assess on the use of water barriers in the typical small crosssection Spanish galleries. Several arrangements of water barriers have been designed and tested to verify the effectiveness of the explosion suppression in each case. The results obtained demonstrate the efficiency of the water barriers in stopping the flame front even with smaller amounts of water than those established by the European standard. According to the tests realized, water barriers activation times are between 0.52 s and 0.78 s and the flame propagation speed are between 75 m/s and 80 m/s. The maximum pressures (Pmax) obtained in the full scale tests have varied between 0.2 bar and 1.8 bar. Passive barriers protect effectively against the spread of the flame but cannot be used as a safeguard of the gallery between the ignition source and the first row of water troughs or bags, or even after them, as the pressure could remain high after them even if the flame front has been extinguished.
Resumo:
During launch, satellite and their equipment are subjected to loads of random nature and with a wide frequency range. Their vibro-acoustic response is an important issue to be analysed, for example for folded solar arrays and antennas. The main issue at low modal density is the modelling combinations engaging air layers, structures and external fluid. Depending on the modal density different methodologies, as FEM, BEM and SEA should be considered. This work focuses on the analysis of different combinations of the methodologies previously stated used in order to characterise the vibro-acoustic response of two rectangular sandwich structure panels isolated and engaging an air layer between them under a diffuse acoustic field. Focusing on the modelling of air layers, different models are proposed. To illustrate the phenomenology described and studied, experimental results from an acoustic test on an ARA-MKIII solar array in folded configuration are presented along with numerical results.
Resumo:
A study on a water- ow window installed in a test box is presented. This window is composed of two glass panes separated by a chamber through water ows. The ow of water comes from an isolated tank which contains heat water. In order to fully evaluate the water- ow window performance for different room and window sizes, locations and weather conditions, a mathematical model of the whole box is needed. The proposed model, in which conduction heat transfer mechanism is the only considered, is one dimensional and unsteady based upon test box energy balance. The effect of the heat water tank, which feeds the water- ow window, is included in the model by means of a time delay in the source term. Although some previous work about moving uid chamber has been developed, air was used as heat transfer uid and no uid storage was considered. Finally a comparison between the numerical solution and the obtained experimental data is done.
Resumo:
Esta tesis examina las implicaciones técnicas, políticas y espaciales del aire urbano, y en concreto, de la calidad del aire, para tenerlo en cuenta desde una perspectiva arquitectónica. En oposición a formas de entender el aire como un vacío o como una metáfora, este proyecto propone abordarlo desde un acercamiento material y tecnológico, trayendo el entorno al primer plano y reconociendo sus múltiples agencias. Debido a la escasa bibliografía detectada en el campo de la arquitectura, el objetivo es construir un marco teórico-analítico para considerar el aire urbano. Para ello el trabajo construye Aeropolis, una metáfora heurística que describe el ensamblaje sociotecnico de la ciudad. Situada en la intersección de determinadas ramas de la filosofía de la cultura, los estudios sobre ciencia y tecnología y estudios feministas de la ciencia este nuevo paisaje conceptual ofrece una metodología y herramientas para abordar el objeto de estudio desde distintos ángulos. Estas herramientas metodológicas han sido desarrolladas en el contexto específico de Madrid, ciudad muy contaminada cuyo aire ha sido objeto de controversias políticas y sociales, y donde las políticas y tecnologías para reducir sus niveles no han sido exitosas. Para encontrar una implicación alternativa con el aire esta tesis propone un método de investigación de agentes invisibles a partir del análisis de sus dispositivos epistémicos. Se centra, en concreto, en los instrumentos que miden, visualizan y comunican la calidad del aire, proponiendo que no sólo lo representan, sino que son también instrumentos que diseñan el aire y la ciudad. La noción de “sensing” (en castellano medir y sentir) es expandida, reconociendo distintas prácticas que reconstruyen el aire de Madrid. El resultado de esta estrategia no es sólo la ampliación de los espacios desde los que relacionarnos con el aire, sino también la legitimación de prácticas existentes fuera de contextos científicos y administrativos, como por ejemplo prácticas relacionadas con el cuerpo, así como la redistribución de agencias entre más actores. Así, esta tesis trata sobre toxicidad, la Unión Europea, producción colaborativa, modelos de computación, dolores de cabeza, kits DIY, gases, cuerpos humanos, salas de control, sangre o políticos, entre otros. Los dispositivos que sirven de datos empíricos sirven como un ejemplo excepcional para investigar infraestructuras digitales, permitiendo desafiar nociones sobre Ciudades Inteligentes. La tesis pone especial atención en los efectos del aire en el espacio público, reconociendo los procesos de invisibilización que han sufrido sus infraestructuras de monitorización. Para terminar se exponen líneas de trabajo y oportunidades para la arquitectura y el diseño urbano a través de nuevas relaciones entre infraestructuras urbanas, el medio construido, espacios domésticos y públicos y humanos y no humanos, para crear nuevas ecologías políticas urbanas (queer). ABSTRACT This thesis examines the technical, political and spatial implications of urban air, and more specifically "air quality", in order to consider it from an architectural perspective. In opposition to understandings of the air either as a void or as a metaphor, this project proposes to inspect it from a material and technical approach, bringing the background to the fore and acknowledging its multiple agencies. Due to the scarce bibliography within the architectural field, its first aim is to construct a theoretical and analytical framework from which to consider urban air. For this purpose, the work attempts the construction of Aeropolis, a heuristic metaphor that describes the city's aero socio-material assemblage. Located at the intersection of certain currents in cultural philosophy, science and technology studies as well as feminist studies in technoscience, this framework enables a methodology and toolset to be extracted in order to approach the subject matter from different angles. The methodological tools stemming from this purpose-built framework were put to the test in a specific case study: Madrid, a highly polluted city whose air has been subject to political and social controversies, and where no effective policies or technologies have been successful in reducing its levels of pollution. In order to engage with the air, the thesis suggests a method for researching invisible agents by examining the epistemic devices involved. It locates and focuses on the instruments that sense, visualise and communicate urban air, claiming that they do not only represent it, but are also instruments that design the air and the city. The notion of "sensing" is then expanded by recognising different practices which enact the air in Madrid. The work claims that the result of this is not only the opening up of spaces for engagement but also the legitimisation of existing practices outside science and policymaking environments, such as embodied practices, as well as the redistribution of agency among more actors. So this is a thesis about toxicity, the European Union, collaborative production, scientific computational models, headaches, DIY kits, gases, human bodies, control rooms, blood, or politicians, among many others. The devices found throughout the work serve as an exceptional substrate for an investigation of digital infrastructures, enabling to challenge Smart City tropes. There is special attention paid to the effects of the air on the public space, acknowledging the silencing processes these infrastructures have been subjected to. Finally there is an outline of the opportunities arising for architecture and urban design when taking the air into account, to create new (queer) urban political ecologies between the air, urban infrastructures, the built environment, public and domestic spaces, and humans and more than humans.
Resumo:
Esta Tesis presenta un estudio sobre el comportamiento vibroacústico de estructuras espaciales que incluyen capas de aire delgadas, así como sobre su modelización numérica. Las capas de aire pueden constituir un elemento fundamental en estos sistemas, como paneles solares plegados, que se consideran el caso de estudio en este trabajo. Para evaluar la influencia de las capas de aire en la respuesta dinámica del sistema se presenta el uso de modelos unidimensionales. La modelización de estos sistemas se estudia para los rangos de baja y alta frecuencia. En el rango de baja frecuencia se propone un conjunto de estrategias de simulación basadas en técnicas numéricas que se utilizan habitualmente en la industria aeroespacial para facilitar la aplicación de los resultados de la Tesis en los modelos numéricos actuales. Los resultados muestran el importante papel de las capas de aire en la respuesta del sistema. El uso de modelos basados en elementos finitos o de contorno para estos elementos proporciona resultados equivalentes aunque la aplicabilidad de estos últimos puede estar condicionada por la geometría del problema. Se estudia asimismo el uso del Análisis Estadístico de la Energía (SEA) para estos elementos. Una de las estrategias de simulación propuestas, que incluye una formulación energética para el aire que rodea a la estructura, se propone como estimador preliminar de la respuesta del sistema y sus frecuencias propias. Para el rango de alta frecuencia, se estudia la influencia de la definición del propio modelo SEA. Se presenta el uso de técnicas de reducción para determinar una matriz de pérdidas SEA reducida para definiciones incompletas del sistema (si algún elemento que interactúa con el resto no se incluye en el modelo). Esta nueva matriz tiene en cuenta la contribución de las subestructuras que no se consideran parte del modelo y que suelen ignorarse en el procedimiento habitual para reducir el tamaño del mismo. Esta matriz permite también analizar sistemas que incluyen algún componente con problemas de accesibilidad para medir su respuesta. Respecto a la determinación de los factores de pérdidas del sistema, se presenta una metodología que permite abordar casos en los que el método usual, el Método de Inyección de Potencia (PIM), no puede usarse. Se presenta un conjunto de métodos basados en la técnicas de optimización y de actualización de modelos para casos en los que no se puede medir la respuesta de todos los elementos del sistema y también para casos en los que no todos los elementos pueden ser excitados, abarcando un conjunto de casos más amplio que el abordable con el PIM. Para ambos rangos de frecuencia se presentan diferentes casos de análisis: modelos numéricos para validar los métodos propuestos y un panel solar plegado como caso experimental que pone de manifiesto la aplicación práctica de los métodos presentados en la Tesis. ABSTRACT This Thesis presents an study on the vibro-acoustic behaviour of spacecraft structures with thin air layers and their numerical modelling. The air layers can play a key role in these systems as solar wings in folded configuration that constitute the study case for this Thesis. A method based on one-dimensional models is presented to assess the influence of the air layers in the dynamic response of the system. The modelling of such systems is studied for low and high frequency ranges. In the low frequency range a set of modelling strategies are proposed based on numerical techniques used in the industry to facilitate the application of the results in the current numerical models. Results show the active role of the air layers in the system response and their great level of influence. The modelling of these elements by means of Finite Elements (FE) and Boundary Elements (BE) provide equivalent results although the applicability of BE models can be conditioned by the geometry of the problem. The use of Statistical Energy Analysis (SEA) for these systems is also presented. Good results on the system response are found for models involving SEA beyond the usual applicability limit. A simulation strategy, involving energetic formulation for the surrounding fluid is proposed as fast preliminary approach for the system response and the coupled eigenfrequencies. For the high frequency range, the influence of the definition of the SEA model is presented. Reduction techniques are used to determine a Reduced SEA Loss Matrix if the system definition is not complete and some elements, which interact with the rest, are not included. This new matrix takes into account the contribution of the subsystems not considered that are neglected in the usual approach for decreasing the size of the model. It also allows the analysis of systems with accessibility restrictions on some element in order to measure its response. Regarding the determination of the loss factors of a system, a methodology is presented for cases in which the usual Power Injection Method (PIM) can not be applied. A set of methods are presented for cases in which not all the subsystem responses can be measured or not all the subsystems can be excited, as solar wings in folded configuration. These methods, based on error minimising and model updating techniques can be used to calculate the system loss factors in a set of cases wider than the PIM’s. For both frequency ranges, different test problems are analysed: Numerical models are studied to validate the methods proposed; an experimental case consisting in an actual solar wing is studied on both frequency ranges to highlight the industrial application of the new methods presented in the Thesis.
Resumo:
This study shows the air flow behavior through the geometry of a freight truck inside a AF6109 wind tunnel with the purpose to predict the speed, pressure and turbulence fields made by the air flow, to decrease the aerodynamic resistance, to calculate the dragging coefficient, to evaluate the aerodynamics of the geometry of the prototype using the CFD technique and to compare the results of the simulation with the results obtained experimentally with the “PETER 739 HAULER” scaled freight truck model located on the floor of the test chamber. The Geometry went through a numerical simulation process using the CFX 5,7. The obtained results showed the behavior of the air flow through the test chamber, and also it showed the variations of speed and pressure at the exit of the chamber and the calculations of the coefficient and the dragging force on the geometry of the freight truck. The evaluation of the aerodynamics showed that the aerodynamic deflector is a device that helped the reduction the dragging produced in a significant way by the air. Furthermore, the dragging coefficient and force on the prototype freight truck could be estimated establishing an incomplete similarity.